Specifications
2-4
2.4
Physical specifications
Table 2.5 Physical specifications
No.
Item
M3097DE/DG
Height
234 ( 9.2 in.)
Width
696 (27.4 in.)
1
Dimensions
(mm)
Depth
497 (19.6 in.)
2
Weight (Kg)
20 ( 44.2 lb)
Voltage (VAC)
100 to 120, 200 to 240 VAC
±
10%
Phase
Single
3
Power
requirements
Frequency
50/60 Hz +2% -4%
4
Power consumption (VA)
120
5
Heat capacity
78 kcal ( 312 BTU/H)
6
Surge current (A)
30
7
Momentary power failure
100 % 0.5 Hz
8
Leakage current (mA)
0.75 or less
9
Dielectric strength
AC 1.5 KV or more for one minute or
more (between FG and AC lines)
10
AC line noise
Voltage 1.2 KV pulse duration 5
µ
s
Operating
+5 to +35
11
Temperature (
°
C)
Non operating
-20 to +60
Operating
20 to 80 (No condensation)
12
Relative humidity
(%)
Non operating
8 to 95 (No condensation)
Operating
0.2
13
Vibration (G)
Non operating
0.4
Operating
5
14
Indication
(degree)
Non operating
10
15
ESD (KV)
8 or more
Operating
53 or less (ISO DIS 9296)
16
Acoustic noise
(dBA)
Non operating
40 or less (ISO DIS 9296)
2.5
Regulation conformity
Table 2.6 Regulation conformity
Item
Conformed regulation
Regulation mark on the
scanner
Remarks
UL 1950
CSA 22.2 950
Yes, CSA NRTL-C mark
Safety
EN60950 1992/A1:1993/A2:1993
Yes, GS mark by TUV
FCC Part15 Class A
Yes
EN55022 1994 Class B
EMI
EN50082-1 1992
Immunity
EN61000-3-2 1995
Harmonic emission
EMI
etc.
EN61000-3-3 1995
Yes, CE mark
Voltage variation
Summary of Contents for M3097DG
Page 1: ...C150 E103 01EN M3097DG Image Scanner OEM Manual ...
Page 2: ......
Page 4: ...This page is intentionally left blank ...
Page 44: ...3 3 Optional image function 3 23 ...
Page 67: ...5 4 Consumable 5 13 Two rollers are included Figure 5 4 Pick roller ...
Page 70: ...6 3 Figure 6 1 Jam clearance ...