Scanner Interface
Appendix A-70
(1)
SET SUBWINDOW command: COMMAND phase (initiator
→
target)
The SET SUBWINDOW command is used to set subwindows. If this command is issued more than
once, only the one issued directly before the READ command becomes effective.
The SET SUBWINDOW command only works if the IPC-2D or IPC-3D option is equipped. If this
command is received by a scanner without the IPC-2D or IPC-3D option, this scanner returns the
following error information:
•
Status:
B’00001’ (CHECK CONDITION)
•
Sense key:
X’5’ (ILLEGAL REQUEST)
The CDB of this command is shown in the following illustration.
a.
Transfer length: Bytes 6 to 8
Specifies the number of subwindow data bytes sent in the Data Out phase. A 0 means no data
is to be transferred; it is not considered an error.
If the number of bytes is not enough to set a single subwindow, an error occurs.
(2)
Subwindow data: DATA OUT phase (initiator
→
target)
Subwindow data specifies details of a subwindow.
Subwindow data contains one header and one or more subwindow descriptor blocks. Each
subwindow descriptor block specifies the attributes of a subwindow (such as size, position, scan
mode).
7
8
6
5
Byte 0
1
(MSB)
Transfer length
(LSB)
2
9
Operation code X’C0’
Logical unit number
(Reserved)
(Reserved)
Control byte
7
6
5
4
3
2
1
0
Summary of Contents for M3097DG
Page 1: ...C150 E103 01EN M3097DG Image Scanner OEM Manual ...
Page 2: ......
Page 4: ...This page is intentionally left blank ...
Page 44: ...3 3 Optional image function 3 23 ...
Page 67: ...5 4 Consumable 5 13 Two rollers are included Figure 5 4 Pick roller ...
Page 70: ...6 3 Figure 6 1 Jam clearance ...