Indoor unit fan operation status
Function
setting
External Input and
Output PCB
External output
Output signal
Status
Rotary switch
60-10
C
Output of indoor unit
CN47
Off → On
Fan run
On → Off
Fan stop
—
2, B, D
External Input and
Output PCB
CN311
Off → On
Fan run
On → Off
Fan stop
—
1
External Input and
Output PCB
CN312
Off → On
Fan run
On → Off
Fan stop
External Input and Output
PCB
External output
Output signal
Status
Rotary switch
2, B, D
External Input and
Output PCB
CN311
Off → On
Fan run
On → Off
Fan stop
1
External Input and
Output PCB
CN312
Off → On
Fan run
On → Off
Fan stop
Output signal
Condition
On
The indoor unit fan is operating.
Off
The fan is stopped or during cold air prevention.
During thermostat off when in dry mode operation.
Fan run
Fan stop
On
Off
CN47
On
Off
CN311, 312
Indoor unit
Fan run
Fan stop
On
Off
CN311, 312
Indoor unit
3-5. Details of control output function
- (05-28) -
3. External input and output (For indoor unit)
FIELD
WORKING
FIELD
WORKING
Summary of Contents for General AOHH30KMTB
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 07 19 SR_CH01_AS073EG_02 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 07 19 SR_CH02_AS073EG_01 ...
Page 33: ...3 TROUBLESHOOTING 2022 08 22 SR_CH03_AS073EG_01 ...
Page 36: ......
Page 90: ...5 2 Outdoor unit 03 54 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 91: ...4 CONTROL AND FUNCTIONS 2022 08 22 SR_CH04_AS073EG_01 ...
Page 94: ......
Page 129: ...5 FILED WORKING 2022 08 22 SR_CH05_AS073EG_01 ...