3-2. External output
Use an external output cable with appropriate external dimension, depending on the number of ca-
bles to be installed.
¢
Indoor unit
• A twisted pair cable should be used. Maximum length of cable is 25 m.
• Output voltage: High DC 12 V ±2 V, Low 0 V.
• Permissible current: 50 mA
• For details, refer to
"Setting of external input and output"
•
When indicator, etc. are connected directly
Example:
Function setting number 60 is set to "00"
1
2
CN47
LED
PCB
Resistor
Connected device
+
-
•
When connecting with a device equipped with a power supply
Example:
Function setting number 60 is set to "00"
1
2
Connected device
CN47
PCB
Connected device
Relay
(Operation status)
-
+