(2) Cool, Fan, Heat and Dry Mode
Indoor fan motor
Operates according to
the AIR FLOW-
MODE setting.
(Except Monitoring)
Operates according
to the AIR
FLOW-MODE
setting.
Operates according to the
AIR FLOW-MODE
setting besides followings.
Cold air prevention
Defrost operation
Monitoring
See the fan control
page.
Cool
Fan
Heat
Dry
RB unit
discharge valve
RB unit
suction valve
RB unit
by-pass valve
Drain pump
Turns ON-OFF by the drain pump control function
Electrical
expansion valve
Pulse controlled by
the temperature
compensation and
the de-icing function
Stop pulse
Pulse controlled by the
temperature
compensation and the
defrosting function
Pulse controlled
by the temperature
compensation
and the de-icing
function
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
Each operation mode is controlled as below.
(1) Stop motion
Indoor fan motor
: OFF
RB unit discharge valve : OFF
RB unit suction valve
: OFF
RB unit by-pass valve
: OFF
Electric expansion valve
Drain pump
: Stop pulse
: Turns ON-OFF by the drain pump control function
6-3-1 OPERATION MODE CONTROL
6-3 MASTER CONTROL
ON
Heat recovery type
6-3-2 "AUTO"(AUTO CHANOVER) POSITION
"Cool" or "Dry"
"Heat"
"Fan" or "Start"
"Automatic Operation"
Signal reception
"Shunt controller" :
Suction valve OFF
Bypass valve ON
"Electronic expansion Valve" :
40 pulses
"Indoor fan motor" : S-L
O
Demand capacity signal
transmission
"Shunt controller" :
Discharge valve OFF
Demand capacity signal
transmission
NO
50 sec Mask
"Shunt controller" :
Bypass valve ON
"Electronic expansion Valve" :
40 pulses
"Indoor fan motor" : S-L
O
Indoor Fan Motor : S-L
O
Monitoring 1
T
R
=
<Ts–2
T
R
=
>Ts+2
Note2
Heating operation
Cooling operation
NO
NO
YES
YES
Note3
Note3
Note1
AUTO CHANGEOVER operation (HEAT RECOVERY TYPE )
a
"Automatic Operation"
Signal reception
"Automatic Operation"
Signal reception
Monitoring 2
"Mask" means "Timer time-up ".
Remarks
Only
If the autochangeover is selected,the following control is performed.
– 65 –
Summary of Contents for AirStage AB12
Page 76: ...MODELS AB30 AB36 AB45 AB54 RB UNIT For Heat Recovery only 7 2 LARGE CEILING TYPE 76 ...
Page 77: ...MODELS AR7 AR9 AR12 AR14 AR18 RB UNIT For Heat Recovery only 7 3 COMPACT DUCT TYPE 77 ...
Page 79: ...MODELS AR36H AR45H AR60H RB For Heat Recovery only UNIT 7 5 HIGH STATIC PRESSURE DUCT TYPE 79 ...
Page 80: ...MODELS AU7 AU9 AU12 AU14 AU18 RB UNIT For Heat Recovery only 7 6 COMPACT CASSETTE TYPE 80 ...
Page 81: ...MODELS AU20 AU25 AU30 AU36 AU45 AU54 RB UNIT For Heat Recovery only 7 7 NEW CASSETTE TYPE 81 ...
Page 82: ...MODELS 7 8 WALL MOUNTED TYPE AS14 20 24 30 82 ...
Page 83: ...MODEL AOY90 7 9 OUTDOOR UNIT 83 ...
Page 134: ...Models AOY90TPAMF 134 10 DISASSEMBLY ILLUSTRATION ...
Page 135: ...Models AOY90TPAMF 135 ...
Page 137: ...Models AOY90TPAMF 137 ...
Page 142: ...Models ABY12TFAMF ABY14TFAMF 755 653 1 581 338 67 56 56 164 109 126 ABY18TFAMF ABY24TFAMF 142 ...
Page 149: ...Models ABY12TFAMF ABY14TFAMF 755 653 1 581 338 67 56 56 164 109 126 ABY18TFAMF ABY24TFAMF 142 ...
Page 155: ...Models ABY30TFAMF ABY36TFAMF ABY45TFAMF 407 876 1 505 408 435 434 506 3 ABY54TFAMF 148 ...
Page 156: ...Models ABY30TFAMF ABY36TFAMF ABY45TFAMF 387 160 91 91 91 321 386 361 ABY54TFAMF 149 ...
Page 162: ...Models AUY20TFAMF AUY25TFAMF AUY30TFAMF AUY36TFAMF AUY45TFAMF AUY54TFAMF 155 ...
Page 164: ...Models AUY25TLAMA AUY30TLAMA AUY36TLAMA AUY45TLAMA 157 ...
Page 167: ...Models ARY25TFAMF ARY30TFAMF ARY36TFAMF ARY45TFAMF 160 ...
Page 169: ... 162 Model ARY7TFAMF ARY9TFAMF ...
Page 170: ...Model ARY7TFAMF ARY9TFAMF 163 875 ...
Page 171: ...Model ARY12TFAMF ARY14TFAMF ARY18TFAMF 164 431 918 918 163 2 184 1 147 ...
Page 172: ...Model ARY12TFAMF ARY14TFAMF ARY18TFAMF 165 ...
Page 173: ...Model ARY12TFAMF ARY14TFAMF ARY18TFAMF 166 ...
Page 179: ...Model ASY20TFAMF ASY24TFAMF ARY30TFAMF 172 91 876 1 407 1 407 2 407 3 69 ...
Page 199: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan Jan 2002 Printed in Japan ...