14-6. Wired remote controller
DIP switch 1
SW1
Prohibited
SW2
Dual remote controller setting
SW3
Prohibited
SW4
°F/°C switch
SW5
Prohibited
SW6
Memory backup setting
* Do not use DIP switch 2.
¢
Switch location
1
2
3
4
5
6
Front case (back side)
DIP switch 2
DIP switch 1
ON
OFF
¢
DIP switch 1 setting
SW2: Dual remote controller setting
Set the remote controller SW2 according to the following table.
Number of remote controller
Primary unit
Secondary unit
Factory setting
SW2
SW2
1 (Normal)
OFF
—
♦
2 (Dual)
OFF
ON
1 2 3
1 2 3
1 2 3
Indoor unit
Remote controller cable
Primary unit
Secondary
unit
Remote controller
SW4: Switching temperature unit °F / °C
Displayed temperature unit can be switched between Fahrenheit (°F) and Celsius (°C).
SW4
Fahrenheit (°F) / Celsius (°C)
Factory setting
OFF
°C
ON
°F
♦
- 155 -
14-6. Wired remote controller
14. Function settings
MULTI TYPE
2, 3, 4 ROOMS TYPE
MULTI TYPE
2, 3, 4 ROOMS TYPE