Indoor units: 7,000 Btu + 18,000 Btu
Indoor temperature
°FDB
60
65
70
75
78
Outdoor temperature
°FDB
°FWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
5
3
16.91
2.52
16.37
2.59
15.82
2.67
15.27
2.74
14.93
2.79
14
12
19.83
2.63
19.21
2.71
18.56
2.79
17.91
2.86
17.51
2.91
23
19
22.39
2.70
21.68
2.77
20.95
2.85
20.22
2.93
19.77
2.98
32
28
25.29
2.70
24.49
2.77
23.66
2.85
22.83
2.93
22.33
2.98
41
37
28.18
2.70
27.29
2.77
26.37
2.85
25.44
2.93
24.88
2.98
47
43
29.93
2.77
28.98
2.85
28.00
2.93
27.02
3.00
26.43
3.00
50
47
30.91
2.72
29.94
2.80
28.93
2.88
27.91
2.96
27.30
3.00
59
50
30.77
2.25
29.80
2.31
28.79
2.38
27.78
2.45
27.17
2.49
68
59
29.85
1.89
28.91
1.94
27.93
2.00
26.95
2.06
26.36
2.09
75
65
29.96
1.87
29.01
1.92
28.03
1.98
27.05
2.03
26.45
2.07
Indoor temperature
°CDB
15.6
18.3
21.2
23.9
25.6
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15.0
-16.1
4.96
2.52
4.80
2.59
4.64
2.67
4.47
2.74
4.38
2.79
-10.0
-11.1
5.81
2.63
5.63
2.71
5.44
2.79
5.25
2.86
5.13
2.91
-5.0
-7.2
6.56
2.70
6.36
2.77
6.14
2.85
5.93
2.93
5.80
2.98
0.0
-2.2
7.41
2.70
7.18
2.77
6.93
2.85
6.69
2.93
6.54
2.98
5.0
2.8
8.26
2.70
8.00
2.77
7.73
2.85
7.46
2.93
7.29
2.98
8.3
6.1
8.77
2.77
8.49
2.85
8.21
2.93
7.92
3.00
7.74
3.00
10.0
8.3
9.06
2.72
8.77
2.80
8.48
2.88
8.18
2.96
8.00
3.00
15.0
10.0
9.02
2.25
8.73
2.31
8.44
2.38
8.14
2.45
7.96
2.49
20.0
15.0
8.75
1.89
8.47
1.94
8.19
2.00
7.90
2.06
7.73
2.09
23.9
18.3
8.78
1.87
8.50
1.92
8.22
1.98
7.93
2.03
7.75
2.07
Indoor units: 9,000 Btu + 9,000 Btu
Indoor temperature
°FDB
60
65
70
75
78
Outdoor temperature
°FDB
°FWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
kBtu/h
kW
5
3
15.61
2.49
15.12
2.56
14.61
2.64
14.10
2.71
13.79
2.76
14
12
18.36
2.63
17.78
2.71
17.17
2.78
16.57
2.86
16.21
2.91
23
19
20.21
2.59
19.57
2.67
18.91
2.74
18.25
2.82
17.85
2.87
32
28
22.62
2.52
21.91
2.59
21.17
2.66
20.43
2.74
19.98
2.78
41
37
25.05
2.44
24.26
2.51
23.44
2.58
22.62
2.66
22.12
2.70
47
43
26.72
2.54
25.88
2.61
25.00
2.69
24.13
2.77
23.59
2.81
50
47
28.02
2.54
27.14
2.61
26.22
2.68
25.30
2.76
24.74
2.80
59
50
28.33
2.21
27.44
2.27
26.51
2.34
25.58
2.40
25.02
2.44
68
59
25.14
1.85
24.35
1.91
23.52
1.96
22.70
2.02
22.20
2.05
75
65
24.63
1.51
23.86
1.55
23.05
1.60
22.24
1.64
21.75
1.67
Indoor temperature
°CDB
15.6
18.3
21.2
23.9
25.6
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15.0
-16.1
4.58
2.49
4.43
2.56
4.28
2.64
4.13
2.71
4.04
2.76
-10.0
-11.1
5.38
2.63
5.21
2.71
5.03
2.78
4.86
2.86
4.75
2.91
-5.0
-7.2
5.92
2.59
5.74
2.67
5.54
2.74
5.35
2.82
5.23
2.87
0.0
-2.2
6.63
2.52
6.42
2.59
6.20
2.66
5.99
2.74
5.85
2.78
5.0
2.8
7.34
2.44
7.11
2.51
6.87
2.58
6.63
2.66
6.48
2.70
8.3
6.1
7.83
2.54
7.58
2.61
7.33
2.69
7.07
2.77
6.91
2.81
10.0
8.3
8.21
2.54
7.95
2.61
7.68
2.68
7.42
2.76
7.25
2.80
15.0
10.0
8.30
2.21
8.04
2.27
7.77
2.34
7.50
2.40
7.33
2.44
20.0
15.0
7.37
1.85
7.14
1.91
6.89
1.96
6.65
2.02
6.51
2.05
23.9
18.3
7.22
1.51
6.99
1.55
6.76
1.60
6.52
1.64
6.38
1.67
- 231 -
6-3. Heating capacity
6. Capacity table
OUTDOOR UNIT
AOU24RLXFZ
OUTDOOR UNIT
AOU24RLXFZ