Combination of external input and output
By combining the function setting of the indoor unit and rotary switch setting of the External input
and output PCB, you can select various combinations of functions.
Combination examples of external input and output are as follows:
Mode
Function
setting
External input
and output PCB
(Rotary SW)
External input
External input and output PCB
CN313
CN314
Signal type
0-1
60-00
1
Operation/Stop
Not available
Edge
Operation
Stop
Pulse
0-2
60-00
2
Forced Thermostat
OFF
Not available
Edge
1—8
60-01 to
60-08
3 - 9, A
(Setting prohibited)
9
60-09
B
Forced Thermostat
OFF
Not available
Edge
10
60-10
C
Forced Thermostat
OFF
Not available
Edge
11
60-11
D
Forced Thermostat
OFF
Not available
Edge
Mode
Function
setting
External input
and output PCB
(Rotary SW)
External output
External input and output PCB
CN310
CN311
CN312
0-1
60-00
1
Operation/Stop
Error status
Indoor unit fan
operation status
0-2
60-00
2
Error status
Indoor unit fan
operation status
Not available
1—8
60-01 to
60-08
3 - 9, A
(Setting prohibited)
9
60-09
B
Operation/Stop
Indoor unit fan
operation status
Not available
10
60-10
C
Operation/Stop
Error status
Not available
11
60-11
D
Operation/Stop
Indoor unit fan
operation status
Error status
NOTE:
Input of Operation/Stop depends on the setting of function setting 46.
00: Operation/Stop mode 1 (R.C. enabled)
01: (Setting prohibited)
02: Forced stop
03: Operation/Stop mode 2 (R.C. disabled)
- 159 -
11-2. Wall mounted type (KGTB, 18-24KMTB, KETA, and KETA-B)
11. External input and output
4-5 UNIT
MULTI-SPLIT TYPE
4-5 UNIT
MULTI-SPLIT TYPE