background image

AOYG36KBTA5

Combination no.

Unit 1

Unit 2

Unit 3

Unit 4

Unit 5

Total

108

7

9

14

24

54

109

7

9

18

18

52

110

7

12

12

12

43

111

7

12

12

14

45

112

7

12

12

18

49

113

7

12

14

14

47

114

7

12

14

18

51

115

7

14

14

14

49

116

7

14

14

18

53

117

9

9

9

9

36

118

9

9

9

12

39

119

9

9

9

14

41

120

9

9

9

18

45

121

9

9

9

22

49

122

9

9

9

24

51

123

9

9

12

12

42

124

9

9

12

14

44

125

9

9

12

18

48

126

9

9

12

22

52

127

9

9

12

24

54

128

9

9

14

14

46

129

9

9

14

18

50

130

9

9

18

18

54

131

9

12

12

12

45

132

9

12

12

14

47

133

9

12

12

18

51

134

9

12

14

14

49

135

9

12

14

18

53

136

9

14

14

14

51

137

12

12

12

12

48

138

12

12

12

14

50

139

12

12

12

18

54

140

12

12

14

14

52

141

12

14

14

14

54

142

7

7

7

7

7

35

143

7

7

7

7

9

37

144

7

7

7

7

12

40

145

7

7

7

7

14

42

146

7

7

7

7

18

46

147

7

7

7

7

22*

50

148

7

7

7

7

24

52

149

7

7

7

9

9

39

150

7

7

7

9

12

42

151

7

7

7

9

14

44

152

7

7

7

9

18

48

153

7

7

7

9

22*

52

154

7

7

7

9

24

54

155

7

7

7

12

12

45

156

7

7

7

12

14

47

157

7

7

7

12

18

51

158

7

7

7

14

14

49

159

7

7

7

14

18

53

160

7

7

9

9

9

41

161

7

7

9

9

12

44

162

7

7

9

9

14

46

- 8 -

1-1. Indoor unit connection patterns

1. Model lineup

4-5 UNIT

MULTI-SPLIT TYPE

4-5 UNIT

MULTI-SPLIT TYPE

Summary of Contents for ABYG18KRTA

Page 1: ...P ARXG09KLLAP ARXG12KLLAP ARXG14KLLAP ARXG18KLLAP ARXG22KMLB ASYG07KGTB ASYG09KGTB ASYG12KGTB ASYG14KGTB ASYG18KMTB ASYG22KMTB ASYG24KMTB ASYG07KMTB ASYG09KMTB ASYG12KMTB ASYG14KMTB ASYG07KMCC ASYG09KMCC ASYG12KMCC ASYG14KMCC ASYG07KETA ASYG09KETA ASYG12KETA ASYG14KETA OUTDOOR ASYG07KETA B ASYG09KETA B ASYG12KETA B ASYG14KETA B ABYG18KRTA ABYG22KRTA AGYG09KVCA AGYG12KVCA AGYG14KVCA AOYG30KBTA4 AOY...

Page 2: ...ease check with our authorized dealer Trademarks FGLair is trademark of Fujitsu General Limited in the United States other countries or both Google Play is trademark of Google Inc App Store is a service mark of Apple Inc registered in the U S and other countries Copyright 2020 2021 Fujitsu General Limited All rights reserved ...

Page 3: ...ted type 34 3 6 Ceiling type 42 3 7 Floor type 44 4 Wiring diagrams 46 4 1 Compact cassette type 46 4 2 Mini duct type and Slim duct type 47 4 3 Medium static pressure duct type 48 4 4 Wall mounted type 49 4 5 Ceiling type 54 4 6 Floor type 55 5 Air velocity and temperature distributions 56 5 1 Compact cassette type 56 5 2 Mini duct type 64 5 3 Slim duct type 74 5 4 Wall mounted type 84 5 5 Ceilin...

Page 4: ...2 Wireless remote controller AR REW2E 197 13 3 Wireless remote controller AR REM7E 199 13 4 Wireless remote controller UTY LNTY Optional part 201 13 5 IR receiver kit with Wireless remote controller UTY LBTYM Optional part 203 13 6 Wired remote controller UTY RNNYM Optional part 206 13 7 Wired remote controller UTY RLRY Optional part 210 13 8 Wired remote controller UTY RVNYM Optional part 213 13 ...

Page 5: ... Mini duct type 282 15 3 Slim duct type 284 15 4 Medium static pressure duct type 285 15 5 Wall mounted type 286 15 6 Ceiling type 289 15 7 Floor type 290 16 Optional parts 291 16 1 Controllers 291 16 2 Cassette grille 294 16 3 Others 295 17 Indoor unit installation precautions 299 17 1 Places where prohibited for use 299 17 2 Points to remember when installing 299 CONTENTS continued ...

Page 6: ...n 354 8 1 Model AOYG30KBTA4 354 9 Airflow 355 9 1 Model AOYG30KBTA4 355 10 Operation noise sound pressure 356 10 1 Noise level curve 356 10 2 Sound level check point 356 11 Electrical characteristics 357 12 Safety devices 358 13 Function settings 359 13 1 Setting methods 359 13 2 Outdoor unit low noise operation function option 362 13 3 Changing the current limit function 362 14 Check and test 363...

Page 7: ... calculation 430 8 1 Model AOYG36KBTA5 430 9 Airflow 431 9 1 Model AOYG36KBTA5 431 10 Operation noise sound pressure 432 10 1 Noise level curve 432 10 2 Sound level check point 432 11 Electrical characteristics 433 12 Safety devices 434 13 Function settings 435 13 1 Setting methods 435 13 2 Outdoor unit low noise operation function option 438 13 3 Changing the current limit function 438 14 Check a...

Page 8: ...17 2 Points to remember when installing 453 CONTENTS continued ...

Page 9: ...TIC PRES SURE DUCT TYPE ARXG07KLLAP ARXG09KLLAP ARXG12KLLAP ARXG14KLLAP ARXG18KLLAP ARXG22KMLB WALL MOUNTED TYPE ASYG07KGTB ASYG09KGTB ASYG12KGTB ASYG14KGTB ASYG18KMTB ASYG22KMTB ASYG24KMTB ASYG07KMTB ASYG09KMTB ASYG12KMTB ASYG14KMTB ASYG07KMCC ASYG09KMCC ASYG12KMCC ASYG14KMCC ASYG07KETA B ASYG09KETA B ASYG12KETA B ASYG14KETA B CEILING TYPE FLOOR TYPE ABYG18KRTA ABYG22KRTA AGYG09KVCA AGYG12KVCA AG...

Page 10: ...B ASYG07KGTB ASYG09KGTB ASYG12KGTB ASYG14KGTB ASYG18KMTB ASYG22KMTB ASYG24KMTB ASYG07KMTB ASYG09KMTB ASYG12KMTB ASYG14KMTB ASYG07KMCC ASYG09KMCC ASYG12KMCC ASYG14KMCC ASYG07KETA ASYG09KETA ASYG12KETA ASYG14KETA ASYG07KETA B ASYG09KETA B ASYG12KETA B ASYG14KETA B ABYG18KRTA ABYG22KRTA AGYG09KVCA AGYG12KVCA AGYG14KVCA Outdoor unit AOYG30KBTA4 AOYG36KBTA5 2 1 Model lineup 4 5 UNIT MULTI SPLIT TYPE 4 ...

Page 11: ... 7 18 32 20 7 7 22 36 21 7 7 24 38 22 7 9 9 25 23 7 9 12 28 24 7 9 14 30 25 7 9 18 34 26 7 9 22 38 27 7 9 24 40 28 7 12 12 31 29 7 12 14 33 30 7 12 18 37 31 7 12 22 41 32 7 12 24 43 33 7 14 14 35 34 7 14 18 39 35 7 14 22 43 36 7 14 24 45 37 7 18 18 43 38 7 18 22 47 39 7 18 24 49 40 9 9 9 27 41 9 9 12 30 42 9 9 14 32 43 9 9 18 36 44 9 9 22 40 45 9 9 24 42 46 9 12 12 33 47 9 12 14 35 48 9 12 18 39 4...

Page 12: ...7 12 18 44 77 7 7 14 14 42 78 7 7 14 18 46 79 7 9 9 9 34 80 7 9 9 12 37 81 7 9 9 14 39 82 7 9 9 18 43 83 7 9 12 12 40 84 7 9 12 14 42 85 7 9 12 18 46 86 7 9 14 14 44 87 7 9 14 18 48 88 7 12 12 12 43 89 7 12 12 14 45 90 7 12 12 18 49 91 7 12 14 14 47 92 9 9 9 9 36 93 9 9 9 12 39 94 9 9 9 14 41 95 9 9 9 18 45 96 9 9 12 12 42 97 9 9 12 14 44 98 9 9 12 18 48 99 9 9 14 14 46 100 9 12 12 12 45 101 9 12 ...

Page 13: ...7 7 000 Btu h 9 9 000 Btu h 12 12 000 Btu h 14 14 000 Btu h 5 1 1 Indoor unit connection patterns 1 Model lineup 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 14: ...22 38 22 7 9 24 40 23 7 12 12 31 24 7 12 14 33 25 7 12 18 37 26 7 12 22 41 27 7 12 24 43 28 7 14 14 35 29 7 14 18 39 30 7 14 22 43 31 7 14 24 45 32 7 18 18 43 33 7 18 22 47 34 7 18 24 49 35 9 9 9 27 36 9 9 12 30 37 9 9 14 32 38 9 9 18 36 39 9 9 22 40 40 9 9 24 42 41 9 12 12 33 42 9 12 14 35 43 9 12 18 39 44 9 12 22 43 45 9 12 24 45 46 9 14 14 37 47 9 14 18 41 48 9 14 22 45 49 9 14 24 47 50 9 18 18...

Page 15: ...9 76 7 7 7 22 43 77 7 7 7 24 45 78 7 7 9 9 32 79 7 7 9 12 35 80 7 7 9 14 37 81 7 7 9 18 41 82 7 7 9 22 45 83 7 7 9 24 47 84 7 7 12 12 38 85 7 7 12 14 40 86 7 7 12 18 44 87 7 7 12 22 48 88 7 7 12 24 50 89 7 7 14 14 42 90 7 7 14 18 46 91 7 7 14 22 50 92 7 7 14 24 52 93 7 7 18 18 50 94 7 9 9 9 34 95 7 9 9 12 37 96 7 9 9 14 39 97 7 9 9 18 43 98 7 9 9 22 47 99 7 9 9 24 49 100 7 9 12 12 40 101 7 9 12 14...

Page 16: ...2 45 132 9 12 12 14 47 133 9 12 12 18 51 134 9 12 14 14 49 135 9 12 14 18 53 136 9 14 14 14 51 137 12 12 12 12 48 138 12 12 12 14 50 139 12 12 12 18 54 140 12 12 14 14 52 141 12 14 14 14 54 142 7 7 7 7 7 35 143 7 7 7 7 9 37 144 7 7 7 7 12 40 145 7 7 7 7 14 42 146 7 7 7 7 18 46 147 7 7 7 7 22 50 148 7 7 7 7 24 52 149 7 7 7 9 9 39 150 7 7 7 9 12 42 151 7 7 7 9 14 44 152 7 7 7 9 18 48 153 7 7 7 9 22 ...

Page 17: ...9 177 7 9 9 12 14 51 178 7 9 9 14 14 53 179 7 9 12 12 12 52 180 7 9 12 12 14 54 181 9 9 9 9 9 45 182 9 9 9 9 12 48 183 9 9 9 9 14 50 184 9 9 9 9 18 54 185 9 9 9 12 12 51 186 9 9 9 12 14 53 187 9 9 12 12 12 54 Numbers in column Unit 1 to 5 and Total indicate the indoor unit capacities as follows 7 7 000 Btu h 9 9 000 Btu h 12 12 000 Btu h 14 14 000 Btu h As for the 22 model wall mounted type indoor...

Page 18: ...tages Main1 1 10 Main2 1 10 Pipe type Copper tube Fin type Aluminum Dimensions H W D Net mm 245 570 570 Gross 265 730 625 Weight Net kg 15 Gross 19 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø9 52 Ø3 8 Method Flare Drain hose Material PVC Tip diameter mm Ø25 I D Ø32 O D Operation range Cooling C 18 to 32 RH 80 or less Heating C 16 to 30 Cassette grille Grid type Option Model name UTG UFYF W ...

Page 19: ...0 Pipe type Copper tube Fin type Aluminum Dimensions H W D Net mm 245 570 570 Gross 265 730 625 Weight Net kg 15 16 Gross 19 20 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø12 70 Ø1 2 Method Flare Drain hose Material PVC Tip diameter mm Ø25 I D Ø32 O D Operation range Cooling C 18 to 32 RH 80 or less Heating C 16 to 30 Cassette grille Grid type Option Model name UTG UFYF W Material Polystyren...

Page 20: ... dB A 52 54 55 60 Heating 53 56 57 62 Heat exchanger type Dimensions H W D mm 336 490 26 6 Fin pitch mm 1 3 Rows Stages 2 16 Pipe type Copper tube Fin type Aluminum Enclosure Material Steel sheet Color Dimensions H W D Net mm 198 700 450 Gross 250 930 580 Weight Net kg 15 5 Gross 19 0 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø9 52 Ø3 8 Method Flare Drain hose Material Hard PVC Tip diameter...

Page 21: ...Aluminum Enclosure Material Steel sheet Color Dimensions H W D Net mm 198 900 450 Gross 250 1 130 580 Weight Net kg 18 5 Gross 23 0 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø12 7 Ø1 2 Method Flare Drain hose Material PVC Tip diameter mm Ø25 I D Ø32 O D Operation range Cooling C 18 to 32 RH 80 or less Heating C 16 to 30 NOTES Values mentioned in the table are based on the following conditio...

Page 22: ...exchanger type Dimensions H W D mm 294 500 26 6 294 500 39 9 Fin pitch mm 1 3 Rows Stages 2 14 3 14 Pipe type Copper tube Fin type Aluminum Enclosure Material Steel sheet Color Dimensions H W D Net mm 198 700 620 Gross 276 968 772 Weight Net kg 16 17 Gross 21 22 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø9 52 Ø3 8 Method Flare Drain hose Material PVC Tip diameter mm Ø25 I D Ø32 O D Operatio...

Page 23: ...osure Material Steel sheet Color Dimensions H W D Net mm 198 900 620 Gross 276 1 168 772 Weight Net kg 20 Gross 26 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø12 70 Ø1 2 Method Flare Drain hose Material PVC Tip diameter mm Ø25 I D Ø32 O D Operation range Cooling C 18 to 32 RH 80 or less Heating C 16 to 30 NOTES Values mentioned in the table are based on the following conditions Static pressu...

Page 24: ...ge Cooling C 18 to 32 RH 80 or less Heating C 16 to 30 Drain hose Material Steel Size mm Ø 35 7 I D Ø 38 1 O D NOTES Specifications are based on the following conditions Cooling Indoor temperature of 27 CDB 19 CWB and outdoor temperature of 35 CDB 24 CWB Heating Indoor temperature of 20 CDB 15 CWB and outdoor temperature of 7 CDB 6 CWB Standard static pressure 35 Pa Pipe length 5 m Height differen...

Page 25: ... 4 Rows Stages Main1 2 10 Main2 2 7 Main1 2 10 Main2 2 7 Sub 1 4 Pipe type Copper tube Fin type Aluminum Enclosure Material Polystyrene Color White Pearl white painted Approximate color of Munsell N 9 25 Dimensions H W D Net mm 270 834 215 Gross 277 914 332 Weight Net kg 10 0 Gross 12 5 13 0 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø9 52 Ø3 8 Method Flare Drain hose Material PP HDPE Tip di...

Page 26: ... tube Fin type Aluminum Enclosure Material Polystyrene Color White Pearl white painted Approximate color of Munsell N 9 25 Dimensions H W D Net mm 280 980 240 Gross 322 1 078 346 Weight Net kg 12 5 Gross 18 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø12 70 Ø1 2 Method Flare Drain hose Material PP HDPE Tip diameter mm Ø13 8 I D Ø 15 8 to Ø 16 7 O D Operation range Cooling C 18 to 32 RH 80 or ...

Page 27: ... Stages Main1 2 10 Main2 2 7 Main1 2 10 Main2 2 7 Sub 1 4 Pipe type Copper tube Fin type Aluminum Enclosure Material Polystyrene Color White Pearl white painted Approximate color of Munsell N 9 25 Dimensions H W D Net mm 270 834 222 Gross 277 914 332 Weight Net kg 10 0 Gross 12 5 13 0 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø9 52 Ø3 8 Method Flare Drain hose Material PP HDPE Size mm Ø13 8...

Page 28: ...n1 2 10 Main2 2 7 Main1 2 10 Main2 2 7 Sub 1 4 Pipe type Copper tube Fin type Aluminum Enclosure Material Polystyrene Color White Pearl white painted Approximate color of Munsell N 9 25 Dimensions H W D Net mm 270 834 222 Gross 277 914 332 Weight Net kg 10 0 Gross 12 5 13 0 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø9 52 Ø3 8 Method Flare Drain hose Material PP HDPE Tip diameter mm Ø13 8 I ...

Page 29: ...n2 2 7 Main1 2 10 Main2 2 7 Sub 1 4 Pipe type Copper tube Fin type Aluminum Enclosure Material Polystyrene Color KETA White Pearl white painted Approximate color of Munsell N 9 25 KETA B Dark Gray Silver painted Approximate color of Munsell 0 5P 3 5 0 2 Dimensions H W D Net mm 295 950 230 Gross 284 1 027 357 Weight Net kg 11 0 11 5 Gross 14 5 15 0 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø...

Page 30: ...ight Net kg 24 24 Gross 33 33 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø12 70 Ø1 2 Method Flare Drain hose Material PVC Tip diameter mm Ø25 I D Ø32 O D Operation range Cooling C 18 to 32 RH 80 or less Heating C 16 to 30 Remote controller type Wired remote controller Wireless remote controller Mobile app 3 FGLair NOTES Specifications are based on the following conditions Cooling Indoor temp...

Page 31: ...m 600 740 200 Gross 700 820 310 Weight Net kg 14 Gross 18 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 Gas Ø9 52 Ø3 8 Method Flare Drain hose Material PP LLDPE Tip diameter mm Ø13 8 I D Ø15 8 to Ø16 7 O D Operation range Cooling C 18 to 32 RH 80 or less Heating C 30 or less Remote controller type Wireless Wired Simple mobile app option NOTES Specifications are based on the following conditions Coo...

Page 32: ...oor unit 370 540 Hanging bolt position a Ceiling openings 530 530 Hanging bolt position Drain hose A 215 19 30 123 30 262 183 Control Box 146 40 C 620 620 IR receiver Grid type grille View B View C 114 a Ceiling openings Cassette grille Option Grid type mm 580 to 610 24 3 1 Compact cassette type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 33: ...To set 3 direction optional Air outlet shutter plate UTR YDZB must be installed and the out let direction need to be switched to 3 way by remote controller When installing the indoor unit be careful about the maintenance space In 3 way outlet mode changing of ceiling height setting by function setting 20 is prohibited Ceiling height setting function setting 20 is allowed to be changed only in 4 wa...

Page 34: ... Drain port 575 174 752 650 43 33 665 700 650 49 49 92 78 169 56 66 85 P 100 6 600 A 295 198 168 150 78 57 10 30 150 182 193 450 30 153 72 52 Rear view Top view Front view Bottom view Side view View A 26 3 2 Mini duct type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 35: ... Top view Side view Front view Bottom view 775 174 153 72 52 295 30 49 85 952 850 P 100 8 800 49 92 78 169 56 66 10 30 150 182 193 450 850 43 33 864 900 198 168 150 78 57 27 3 2 Mini duct type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 36: ... or more 20 or more 300 or more Air When intaking air from bottom 100 or more Air Maintenance space requirement For future maintenance and service access provide sufficient maintenance space NOTE Do not place any wiring or illumination in the maintenance space as they will impede ser vice Unit mm Top view Service access Air Air Control box 400 or more 100 or more 300 or more Service space More tha...

Page 37: ... Rear view View A Top view Side view Front view Bottom view Drain port 51 574 174 71 152 100 x 6 600 82 48 650 734 30 377 167 119 89 78 55 47 10 620 371 264 144 69 650 664 700 43 20 198 168 151 78 55 29 3 3 Slim duct type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 38: ...de view Front view Bottom view Drain port 51 774 174 71 152 87 56 850 934 100 8 800 30 377 167 119 89 78 55 47 10 620 371 264 144 69 850 864 900 43 20 198 168 151 78 55 A 30 3 3 Slim duct type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 39: ... ceiling Floor 240 or more 20 or more 20 or more 300 or more Unit mm Maintenance space requirement For future maintenance and service access provide sufficient maintenance space NOTE Do not place any wiring or illumination in the maintenance space as they will impede ser vice Service access Unit mm Unit Control box Service space 400 or more 300 or more 100 or more 31 3 3 Slim duct type 3 Dimension...

Page 40: ...38 P125 3 375 Φ3 2 80 80 Φ205 75 82 80 80 264 Φ3 2 264 264 270 240 121 80 80 32 161 80 80 Φ200 40 700 173 477 73 107 1 135 1 015 120 1 177 Φ5 P125 3 375 Φ5 16 34 270 240 170 32 66 114 281 240 168 283 39 54 Air Installation space requirement Unit mm 300 or more 150 or more 20 or more 32 3 4 Medium static pressure duct type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 41: ...00 The service access necessary for fan units and filter maintenance Maintenance hole Intake panel 300 1 550 500 100 Control box When using a square duct P174 6 1 044 Φ3 2 46 23 18 219 109 Bottom air intake hole 108 1 015 16 240 33 3 4 Medium static pressure duct type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 42: ...KGTB and ASYG14KGTB Unit mm 834 834 Outline of indoor unit 327 273 273 54 215 3 0 270 270 43 43 9 5 220 for pipe inlet Ø65 for pipe inlet Ø65 182 182 356 346 48 84 63 63 34 3 5 Wall mounted type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 43: ...nit mm Wall hook bracket Outline of the indoor unit 50 or more 67 or more The flare connection part should be installed outdoors 40 or more 70 or more 107 or more 1 500 or more 1 800 or more 183 or more 35 3 5 Wall mounted type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 44: ...TB and ASYG24KMTB Unit mm 980 240 280 Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 37 37 400 90 413 77 73 417 61 429 115 72 36 3 5 Wall mounted type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 45: ...nit mm Wall hook bracket Outline of the indoor unit 50 or more 71 or more 40 or more 70 or more 117 or more 1 500 or more 1 800 or more 160 or more The flare connection part should be installed outdoors 37 3 5 Wall mounted type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 46: ...KMCC ASYG12KMCC and ASYG14KMCC Unit mm 834 Outline of indoor unit 327 273 273 54 270 43 43 9 5 220 for pipe inlet Ø65 for pipe inlet Ø65 182 182 356 346 48 84 63 63 834 270 222 3 0 38 3 5 Wall mounted type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 47: ...nit mm Wall hook bracket Outline of the indoor unit 50 or more 67 or more The flare connection part should be installed outdoors 40 or more 70 or more 107 or more 1 500 or more 1 800 or more 183 or more 39 3 5 Wall mounted type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 48: ...A B ASYG12KETA B and ASYG14KETA B 950 Outline of indoor unit 327 273 273 54 295 43 43 9 5 220 for pipe inlet Ø65 for pipe inlet Ø65 182 182 356 346 106 142 63 63 950 295 230 3 0 Unit mm 40 3 5 Wall mounted type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 49: ...nit mm Wall hook bracket Outline of the indoor unit 50 or more 67 or more The flare connection part should be installed outdoors 40 or more 40 or more 166 or more 1 500 or more 1 800 or more 211 or more 41 3 5 Wall mounted type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 50: ...Top view Indoor unit Dimensions Space required for installation The length of the bolt here is 30 mm 75 10 175 290 75 49 84 55 110 923 1 080 145 181 349 119 98 125 103 235 100 125 91 80 140 705 206 179 115 41 290 178 313 89 ø100 mm hole 89 110 42 3 6 Ceiling type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 51: ... or more 0 or more Obstruction Floor Indoor unit Required ceiling height varies according to the ceiling mode setting of function setting No 20 Ceiling height m Ceiling mode Standard High ceiling 18 22 models 2 7 3 5 43 3 6 Ceiling type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 52: ...G12KVCA and AGYG14KVCA 600 200 Side view Front view 740 Unit mm Installation space 100 or more 80 or more 80 or more 150 or below from the floor 50 or more 44 3 7 Floor type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 53: ...ger than X m2 Amount of refrigerant charge M kg Minimum room area X m2 M 1 22 1 22 M 1 23 12 99 1 23 M 1 50 19 31 1 50 M 1 75 26 28 1 75 M 2 0 34 33 2 0 M 2 5 53 63 2 5 M 3 0 77 23 3 0 M 3 5 105 12 3 5 M 4 0 137 29 IEC 60335 2 40 45 3 7 Floor type 3 Dimensions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 54: ...diagrams 4 1 Compact cassette type Models AUXG07KVLA AUXG09KVLA AUXG12KVLA AUXG14KVLA AUXG18KVLA and AUXG22KVLA 46 4 1 Compact cassette type 4 Wiring diagrams 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 55: ... ARXG09KSLAP ARXG12KSLAP ARXG14KSLAP ARXG18KSLAP ARXG07KLLAP ARXG09KLLAP ARXG12KLLAP ARXG14KLLAP and ARXG18KLLAP WLAN adapter Converter etc Option 47 4 2 Mini duct type and Slim duct type 4 Wiring diagrams 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 56: ...4 3 Medium static pressure duct type Model ARXG22KMLB 48 4 3 Medium static pressure duct type 4 Wiring diagrams 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 57: ...4 4 Wall mounted type Models ASYG07KGTB ASYG09KGTB ASYG12KGTB and ASYG14KGTB 49 4 4 Wall mounted type 4 Wiring diagrams 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 58: ... Models ASYG18KMTB ASYG22KMTB and ASYG24KMTB 50 4 4 Wall mounted type 4 Wiring diagrams 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 59: ... Models ASYG07KMTB ASYG09KMTB ASYG12KMTB and ASYG14KMTB 51 4 4 Wall mounted type 4 Wiring diagrams 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 60: ... Models ASYG07KMCC ASYG09KMCC ASYG12KMCC and ASYG14KMCC 52 4 4 Wall mounted type 4 Wiring diagrams 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 61: ... Models ASYG07KETA ASYG09KETA ASYG12KETA ASYG14KETA ASYG07KETA B ASYG09KETA B ASYG12KETA B and ASYG14KETA B 53 4 4 Wall mounted type 4 Wiring diagrams 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 62: ...4 5 Ceiling type Models ABYG18KRTA and ABYG22KRTA 54 4 5 Ceiling type 4 Wiring diagrams 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 63: ...4 6 Floor type Models AGYG09KVCA AGYG12KVCA and AGYG14KVCA 55 4 6 Floor type 4 Wiring diagrams 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 64: ... Vertical airflow direction louver up 2 0 2 0 2 0 2 0 1 0 1 0 1 0 1 0 0 5 0 5 0 5 0 5 0 25 0 25 0 25 0 25 Unit m s 4 3 2 1 0 1 2 3 4 4 3 2 1 0 1 2 3 4 m m Side view Vertical airflow direction louver up 2 0 1 0 0 5 0 5 0 25 0 25 4 3 2 1 0 1 2 3 4 m 0 1 2 2 7 m Unit m s 56 5 1 Compact cassette type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 65: ... 3 2 1 0 1 2 3 4 m 0 1 2 2 7 m 2 5 Unit m s Air temperature distribution Measuring conditions NOTE Reference data Fan speed Operation mode Outlet directions HIGH HEAT 4 way air outlet Side view Vertical airflow direction louver down 30 30 28 28 26 26 24 24 22 22 4 3 2 1 0 1 2 3 4 m 0 1 2 2 7 m 2 5 Unit C 57 5 1 Compact cassette type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT...

Page 66: ... 0 2 0 2 0 1 0 1 0 1 0 1 0 0 5 0 5 0 5 0 5 0 25 0 25 0 25 0 25 4 3 2 1 0 1 2 3 4 m Unit m s 4 3 2 1 0 1 2 3 4 m Side view Vertical airflow direction louver up 2 0 1 0 0 5 0 5 0 25 0 25 4 3 2 1 0 1 2 3 4 m 0 1 2 2 7 m Unit m s 58 5 1 Compact cassette type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 67: ... 2 7 m 2 5 4 3 2 1 0 1 2 3 4 m Unit m s Air temperature distribution Measuring conditions NOTE Reference data Fan speed Operation mode Outlet directions HIGH HEAT 4 way air outlet Side view Vertical airflow direction louver down 30 30 28 28 26 26 24 24 22 22 0 1 2 2 7 m 2 5 4 3 2 1 0 1 2 3 4 m Unit C 59 5 1 Compact cassette type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYP...

Page 68: ...up 1 0 5 0 5 1 2 0 25 0 25 1 0 25 2 0 25 0 5 2 0 5 1 2 4 3 2 1 0 1 2 3 4 m Unit m s 4 3 2 1 0 1 2 3 4 m Side view Vertical airflow direction louver up 0 25 0 25 0 5 0 5 1 1 2 2 4 3 2 1 0 1 2 3 4 m 0 1 2 2 7 m Unit m s 60 5 1 Compact cassette type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 69: ...2 2 7 m 2 5 4 3 2 1 0 1 2 3 4 m Unit m s Air temperature distribution Measuring conditions NOTE Reference data Fan speed Operation mode Outlet directions HIGH HEAT 4 way air outlet Side view Vertical airflow direction louver down 22 24 26 28 30 0 1 2 2 7 m 2 5 4 3 2 1 0 1 2 3 4 m Unit C 61 5 1 Compact cassette type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MUL...

Page 70: ... 0 25 0 25 1 1 0 25 0 25 0 5 0 5 1 1 2 2 2 2 Side view Vertical airflow direction louver Upward 3 2 1 0 Unit m s m m 4 3 2 1 0 1 2 3 4 0 25 0 25 0 5 0 5 1 1 2 Side view Vertical airflow direction louver Downward 3 2 1 0 Unit m s m m 4 3 2 1 0 1 2 3 4 0 25 0 5 0 5 1 1 0 25 2 2 62 5 1 Compact cassette type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TY...

Page 71: ...2 2 1 1 1 1 0 5 0 5 0 25 0 5 0 25 0 5 0 25 0 25 Side view Vertical airflow direction louver Upward 3 2 1 0 Unit m s m m 4 3 2 1 0 1 2 3 4 2 1 1 0 5 0 5 0 25 0 25 Side view Vertical airflow direction louver Downward 3 2 1 0 Unit m s m m 4 3 2 1 0 1 2 3 4 0 25 0 25 0 5 0 5 1 1 2 2 63 5 1 Compact cassette type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT...

Page 72: ...2 1 0 1 2 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 1 0 5 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 1 0 1 2 m m Unit m s 0 1 2 3 4 5 6 7 5 4 3 8 9 10 5 4 3 2 1 0 5 2 1 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 1 0 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 5 3 1 0 5 2 64 5 2 Mini duct type 5 Air veloc...

Page 73: ... 0 1 2 3 4 5 6 7 8 9 10 2 5 3 2 1 0 5 Air temperature distribution Measuring conditions Fan speed Operation mode HIGH HEAT Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 1 0 m Unit C m 0 1 2 3 4 5 6 7 8 9 2 5 3 10 30 28 26 24 22 65 5 2 Mini duct type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 74: ... m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 1 0 5 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 1 0 1 2 m m Unit m s 0 1 2 3 4 5 6 7 5 4 3 8 9 10 5 4 3 2 1 0 5 2 1 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 1 0 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 5 3 1 0 5 2 66 5 2 Mini duct type 5 Air velocity and t...

Page 75: ... 0 1 2 3 4 5 6 7 8 9 10 2 5 3 2 1 0 5 Air temperature distribution Measuring conditions Fan speed Operation mode HIGH HEAT Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 1 0 m Unit C m 0 1 2 3 4 5 6 7 8 9 2 5 3 10 30 28 26 24 22 67 5 2 Mini duct type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 76: ... m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 1 0 5 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 1 0 1 2 m m Unit m s 0 1 2 3 4 5 6 7 5 4 3 8 9 10 5 4 3 2 1 0 5 2 1 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 1 0 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 5 3 1 0 5 2 68 5 2 Mini duct type 5 Air velocity and t...

Page 77: ...4 5 6 7 8 9 10 2 5 3 2 1 0 5 Unit m s Air temperature distribution Measuring conditions Fan speed Operation mode HIGH HEAT Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 1 0 m Unit C m 0 1 2 3 4 5 6 7 8 9 2 5 3 10 30 28 26 24 22 69 5 2 Mini duct type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 78: ... m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 1 0 5 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 1 0 1 2 m m Unit m s 0 1 2 3 4 5 6 7 5 4 3 8 9 10 5 4 3 2 1 0 5 2 1 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 1 0 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 5 3 1 0 5 2 70 5 2 Mini duct type 5 Air velocity and t...

Page 79: ... 0 1 2 3 4 5 6 7 8 9 10 2 5 3 2 1 0 5 Air temperature distribution Measuring conditions Fan speed Operation mode HIGH HEAT Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 1 0 m Unit C m 0 1 2 3 4 5 6 7 8 9 2 5 3 10 30 28 26 24 22 71 5 2 Mini duct type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 80: ... m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 1 0 5 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 1 0 1 2 m m Unit m s 0 1 2 3 4 5 6 7 5 4 3 8 9 10 5 4 3 2 1 0 5 2 1 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 1 0 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 5 3 1 0 5 2 72 5 2 Mini duct type 5 Air velocity and t...

Page 81: ...4 5 6 7 8 9 10 2 5 3 Unit m s 2 1 0 5 Air temperature distribution Measuring conditions Fan speed Operation mode HIGH HEAT Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 1 0 m Unit C m 0 1 2 3 4 5 6 7 8 9 2 5 3 10 30 28 26 24 22 73 5 2 Mini duct type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 82: ...2 1 0 1 2 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 1 0 5 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 1 0 1 2 m m Unit m s 0 1 2 3 4 5 6 7 5 4 3 8 9 10 5 4 3 2 1 0 5 2 1 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 1 0 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 5 3 1 0 5 2 74 5 3 Slim duct type 5 Air veloc...

Page 83: ... 0 1 2 3 4 5 6 7 8 9 10 2 5 3 2 1 0 5 Air temperature distribution Measuring conditions Fan speed Operation mode HIGH HEAT Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 1 0 m Unit C m 0 1 2 3 4 5 6 7 8 9 2 5 3 10 30 28 26 24 22 75 5 3 Slim duct type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 84: ... m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 1 0 5 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 1 0 1 2 m m Unit m s 0 1 2 3 4 5 6 7 5 4 3 8 9 10 5 4 3 2 1 0 5 2 1 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 1 0 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 5 3 1 0 5 2 76 5 3 Slim duct type 5 Air velocity and t...

Page 85: ... 0 1 2 3 4 5 6 7 8 9 10 2 5 3 2 1 0 5 Air temperature distribution Measuring conditions Fan speed Operation mode HIGH HEAT Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 1 0 m Unit C m 0 1 2 3 4 5 6 7 8 9 2 5 3 10 30 28 26 24 22 77 5 3 Slim duct type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 86: ... m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 1 0 5 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 1 0 1 2 m m Unit m s 0 1 2 3 4 5 6 7 5 4 3 8 9 10 5 4 3 2 1 0 5 2 1 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 1 0 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 5 3 1 0 5 2 78 5 3 Slim duct type 5 Air velocity and t...

Page 87: ...4 5 6 7 8 9 10 2 5 3 2 1 0 5 Unit m s Air temperature distribution Measuring conditions Fan speed Operation mode HIGH HEAT Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 1 0 m Unit C m 0 1 2 3 4 5 6 7 8 9 2 5 3 10 30 28 26 24 22 79 5 3 Slim duct type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 88: ... m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 1 0 5 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 1 0 1 2 m m Unit m s 0 1 2 3 4 5 6 7 5 4 3 8 9 10 5 4 3 2 1 0 5 2 1 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 1 0 m Unit m s m 0 1 2 3 4 5 6 7 8 9 10 2 5 3 1 0 5 2 80 5 3 Slim duct type 5 Air velocity and t...

Page 89: ... 0 1 2 3 4 5 6 7 8 9 10 2 5 3 2 1 0 5 Air temperature distribution Measuring conditions Fan speed Operation mode HIGH HEAT Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 2 1 0 m Unit C m 0 1 2 3 4 5 6 7 8 9 2 5 3 10 30 28 26 24 22 81 5 3 Slim duct type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 90: ...9 8 7 6 5 4 3 2 1 0 m Unit m s 0 1 1 2 2 m Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 0 5 0 5 1 1 2 2 10 9 8 7 6 5 4 3 2 1 0 m Unit m s 0 1 1 2 2 3 3 4 4 5 m 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 0 5 1 2 10 9 8 7 6 5 4 3 2 1 0 m Unit m s 0 1 2 2 5 3 m 82 5 3 Slim duct type 5 Air velocity and tem...

Page 91: ...er Center 10 9 8 7 6 5 4 3 2 1 0 m Unit m s 0 1 2 2 5 3 m 0 5 1 2 Air temperature distribution Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 10 9 8 7 6 5 4 3 2 1 0 m Unit C 0 1 2 2 5 3 m 30 28 26 24 22 83 5 3 Slim duct type 5 Air velocity and temperature distributions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 92: ...8 9 10 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 0 2 0 1 0 1 0 0 5 0 5 Unit m s m m 3 2 1 0 1 2 3 0 1 2 3 4 5 6 7 8 9 10 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center m m 3 2 1 0 0 1 2 3 4 5 6 7 8 9 10 Unit m s 2 0 0 5 1 0 Side view Vertical airflow direction louver Down Horizontal airflow direction lo...

Page 93: ...rection louver Left Right 2 0 2 0 1 0 1 0 0 5 0 5 Unit m s m m 3 2 1 0 1 2 3 0 1 2 3 4 5 6 7 8 9 10 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center m m 3 2 1 0 0 1 2 3 4 5 6 7 8 9 10 Unit m s 2 0 0 5 1 0 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center m m 3 2 1 0 0 1 2 3 4 5 6 7 8 9 10 0 5 0 5 2 0 1 0 Unit m s 85...

Page 94: ...izontal airflow direction louver Left Right 1 0 1 0 0 5 0 5 2 0 2 0 Unit m s m m 3 2 1 0 1 2 3 0 1 2 3 4 5 6 7 8 9 10 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 0 0 5 1 0 m m 3 2 1 0 0 1 2 3 4 5 6 7 8 9 10 Unit m s Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 0 5 0 5 2 0 1 0 m m 3 2 1 0 0 1 2 3 4 5 6 7 ...

Page 95: ... louver Left Right 2 0 2 0 0 25 0 25 0 5 0 5 1 0 1 0 0 0 1 2 3 4 5 6 7 8 9 10 11 12 m m 1 1 2 2 3 3 4 4 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center m 0 1 2 3 4 5 6 7 8 9 10 11 12 m 0 1 2 2 7 2 0 1 0 0 5 0 25 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center m 0 1 2 3 4 5 6 7 8 9 10 11 12 m 0 1 2 2 7 2 0 1 0 0 5...

Page 96: ...Left Right 2 0 2 0 0 25 0 25 0 5 0 5 1 0 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 m m 1 1 2 2 3 3 4 4 0 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 0 1 2 3 4 5 6 7 8 9 10 11 12 m 0 1 2 2 0 0 25 0 5 1 0 m 2 7 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center m 0 1 2 3 4 5 6 7 8 9 10 11 12 m 0 1 2 2 7 0 5 0 25 2 0 1 0 88...

Page 97: ...cal airflow direction louver Up Horizontal airflow direction louver Left Right 1 0 0 5 1 0 0 5 Unit m s 2 1 0 1 2 m m 1 2 3 4 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 1 0 0 5 3 2 1 0 Unit m s m m 1 2 3 4 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 1 0 0 5 3 2 1 0 m m 1 2 3 4 Unit m s 89 5 6 Floor type ...

Page 98: ...3 upper limit SP mode 03 lower limit Normal SP upper limit Quiet Normal SP Hi Normal SP Hi SP mode 00 SP mode 00 upper limit 60 50 40 30 20 10 0 300 External static pressure Pa Airflow m3 h 400 500 600 700 1 Available airflow rate range when Auto louver grille option is installed Fan speed HIGH Vertical airflow direction louver Up Available airflow rate range High level 1 Hi SP mode 00 Hi Normal S...

Page 99: ...300 400 500 700 600 Airflow m3 h 0 20 40 60 80 100 140 120 Capacity Capacity Heating 0 20 40 60 80 100 120 140 300 400 500 700 600 Capacity Airflow m3 h Capacity 91 6 1 Mini duct type 6 Fan performance 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 100: ...mal SP Hi SP mode 00 SP mode 00 upper limit 1 Available airflow rate range when Auto louver grille option is installed Fan speed HIGH Vertical airflow direction louver Up 60 50 40 30 20 10 0 300 External static pressure Pa Airflow m3 h 400 500 600 700 Available airflow rate range High level 1 Hi SP mode 00 Hi Normal SP Hi SP mode 02 Hi SP mode 03 92 6 1 Mini duct type 6 Fan performance 4 5 UNIT MU...

Page 101: ...300 400 500 700 600 Airflow m3 h 0 20 40 60 80 100 140 120 Capacity Capacity Heating 0 20 40 60 80 100 120 140 300 400 500 700 600 Capacity Airflow m3 h Capacity 93 6 1 Mini duct type 6 Fan performance 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 102: ...ode 00 SP mode 00 upper limit Hi SP mode 00 60 50 40 30 20 10 0 300 400 500 600 800 External static pressure Pa Airflow m3 h Available airflow rate range High level 1 700 1 Available airflow rate range when Auto louver grille option is installed Fan speed HIGH Vertical airflow direction louver Up Hi SP mode 03 Hi Normal SP Hi SP mode 02 Hi SP mode 00 94 6 1 Mini duct type 6 Fan performance 4 5 UNI...

Page 103: ...city 800 500 400 700 600 Airflow m3 h 300 0 20 40 60 80 100 140 Capacity 120 Heating 300 500 600 800 700 Airflow m3 h 400 0 20 40 60 80 100 120 Capacity 140 Capacity 95 6 1 Mini duct type 6 Fan performance 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 104: ...e 00 Quiet SP mode 00 80 70 60 50 40 30 20 10 0 External static pressure Pa 300 400 500 600 700 Airflow m3 h 800 900 1 Available airflow rate range when Auto louver grille option is installed Fan speed HIGH Vertical airflow direction louver Up Hi SP mode 01 Hi SP mode 05 Hi SP mode 04 Hi SP mode 03 Hi Normal SP Hi SP mode 02 Hi SP mode 00 Available airflow rate range High level 1 96 6 1 Mini duct ...

Page 105: ...60 80 100 120 Capacity 140 500 600 700 900 800 Airflow m3 h 400 300 Capacity Heating 0 20 40 60 80 100 120 Capacity 140 500 600 700 900 800 Airflow m3 h 400 300 Capacity 97 6 1 Mini duct type 6 Fan performance 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 106: ...de 05 Quiet SP mode 00 1 Available airflow rate range when Auto louver grille option is installed Fan speed HIGH Vertical airflow direction louver Up 80 70 60 50 40 30 20 10 0 External static pressure Pa 700 Airflow m3 h 900 1 000 1 100 800 600 500 400 300 Available airflow rate range High level 1 Hi SP mode 05 Hi SP mode 04 Hi SP mode 03 Hi Normal SP Hi SP mode 02 Hi SP mode 01 Hi SP mode 00 98 6...

Page 107: ...0 Capacity 140 Airflow m3 h 700 900 1 000 1 100 800 300 400 500 600 Capacity Heating 0 20 40 60 80 100 120 Capacity 140 Airflow m3 h 700 900 1 000 1 100 800 300 400 500 600 Capacity 99 6 1 Mini duct type 6 Fan performance 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 108: ... lower limited 110 100 90 80 70 60 50 40 30 20 10 0 300 External static pressure Pa Airflow m3 h 400 500 600 700 1 Available airflow rate range when Auto louver grille option is installed Fan speed HIGH Vertical airflow direction louver Up Hi SP mode 09 Hi SP mode 08 Hi SP mode 07 Hi SP mode 06 Hi SP mode 05 Hi SP mode 04 Hi SP mode 03 Hi Normal SP Hi SP mode 02 Hi SP mode 01 Hi SP mode 00 Availab...

Page 109: ...ing 0 20 40 60 80 100 120 400 500 600 800 700 Capacity Capacity Airflow m3 h Heating 0 20 40 60 80 100 120 400 500 600 800 700 Capacity Capacity Airflow m3 h 101 6 2 Slim duct type 6 Fan performance 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 110: ...00 90 80 70 60 50 40 30 20 10 0 300 External static pressure Pa Airflow m3 h Hi SP mode 09 Hi SP mode 08 Hi SP mode 07 Hi SP mode 06 Hi SP mode 05 Hi SP mode 04 Hi SP mode 03 Hi Normal SP Hi SP mode 02 Hi SP mode 01 Hi SP mode 00 Available airflow rate range High level 1 400 500 600 800 700 1 Available airflow rate range when Auto louver grille option is installed Fan speed HIGH Vertical airflow d...

Page 111: ...ing 0 20 40 60 80 100 120 400 500 600 800 700 Capacity Capacity Airflow m3 h Heating 0 20 40 60 80 100 120 400 500 600 800 700 Capacity Capacity Airflow m3 h 103 6 2 Slim duct type 6 Fan performance 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 112: ...0 90 80 70 60 50 40 30 20 10 0 300 400 500 600 800 External static pressure Pa Airflow m3 h Hi SP mode 09 Hi SP mode 08 Hi SP mode 07 Hi SP mode 06 Hi SP mode 05 Hi SP mode 04 Hi SP mode 03 Hi Normal SP Hi SP mode 02 Hi SP mode 01 Hi SP mode 00 Available airflow rate range High level 1 700 1 Available airflow rate range when Auto louver grille option is installed Fan speed HIGH Vertical airflow di...

Page 113: ...ing 0 20 40 60 80 100 120 900 500 600 800 700 Capacity Capacity Airflow m3 h Heating 900 0 20 40 60 80 100 120 500 600 800 700 Capacity Capacity Airflow m3 h 105 6 2 Slim duct type 6 Fan performance 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 114: ... 90 80 70 60 50 40 30 20 10 0 300 400 500 600 700 External static pressure Pa Airflow m3 h 800 900 1 000 120 1 Available airflow rate range when Auto louver grille option is installed Fan speed HIGH Vertical airflow direction louver Up Hi SP mode 09 Hi SP mode 08 Hi SP mode 07 Hi SP mode 06 Hi SP mode 05 Hi SP mode 04 Hi SP mode 03 Hi Normal SP Hi SP mode 02 Hi SP mode 01 Hi SP mode 00 Available a...

Page 115: ...g 0 20 40 60 80 100 120 1 000 600 700 900 800 Capacity Capacity Airflow m3 h Heating 0 20 40 60 80 100 120 1 000 600 700 900 800 Capacity Capacity Airflow m3 h 107 6 2 Slim duct type 6 Fan performance 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 116: ...0 90 80 70 60 50 40 30 20 10 0 External static pressure Pa Airflow m3 h Hi SP mode 09 Hi SP mode 08 Hi SP mode 07 Hi SP mode 06 Hi SP mode 05 Hi SP mode 04 Hi SP mode 03 Hi Normal SP Hi SP mode 02 Hi SP mode 01 Hi SP mode 00 Available airflow rate range High level 1 700 900 1 000 1 100 1 200 800 600 1 Available airflow rate range when Auto louver grille option is installed Fan speed HIGH Vertical ...

Page 117: ... 20 40 60 80 100 120 Capacity Capacity Airflow m3 h 700 900 1 000 1 100 800 Heating 0 20 40 60 80 100 120 Capacitty Capacity Airflow m3 h 700 900 1 000 1 100 800 109 6 2 Slim duct type 6 Fan performance 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 118: ... s 175 161 146 CFM 371 341 309 Q h Characteristic curve STATIC PRESSURE Pa 50 40 30 20 10 0 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h COOLING Cooling capacity 104 0 102 0 100 0 98 0 96 0 94 0 92 0 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h Capacity HEATING Heating capacity 104 0 102 0 100 0 98 0 96 0 94 0 92 0 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h Ca...

Page 119: ...eristic curve STATIC PRESSURE Pa 70 60 50 40 30 20 10 0 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h COOLING Cooling capacity 104 0 102 0 100 0 98 0 96 0 94 0 92 0 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h Capacity HEATING Heating capacity 104 0 102 0 100 0 98 0 96 0 94 0 92 0 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h Capacity 111 6 3 Medium static pressur...

Page 120: ...stic curve STATIC PRESSURE Pa 110 100 90 80 70 60 50 40 30 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h COOLING Cooling capacity 104 0 102 0 100 0 98 0 96 0 94 0 92 0 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h Capacity HEATING Heating capacity 104 0 102 0 100 0 98 0 96 0 94 0 92 0 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h Capacity 112 6 3 Medium static pres...

Page 121: ...c curve STATIC PRESSURE Pa 150 140 130 120 110 100 90 80 70 60 50 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h COOLING Cooling capacity 104 0 102 0 100 0 98 0 96 0 94 0 92 0 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h Capacity HEATING Heating capacity 104 0 102 0 100 0 98 0 96 0 94 0 92 0 500 600 700 800 900 1 000 1 100 1 200 1 300 Airflow m3 h Capacity 113 6 3 Medium stat...

Page 122: ...h 610 169 359 Med 530 147 312 Low 470 131 277 Quiet 410 114 241 AUXG14KVLA Cooling High 680 189 400 Med 580 161 341 Low 490 136 288 Quiet 410 114 241 Heating High 790 219 465 Med 680 189 400 Low 580 161 341 Quiet 450 125 265 AUXG18KVLA Cooling High 680 189 400 Med 580 161 341 Low 490 136 288 Quiet 410 114 241 Heating High 790 219 465 Med 680 189 400 Low 580 161 341 Quiet 450 125 265 AUXG22KVLA Coo...

Page 123: ... 360 100 212 ARXG12KSLAP Cooling High 650 181 383 Med 490 136 288 Low 430 119 253 Quiet 360 100 212 Heating High 650 181 383 Med 490 136 288 Low 430 119 253 Quiet 360 100 212 ARXG14KSLAP Cooling High 800 222 471 Med 640 178 377 Low 530 147 312 Quiet 360 100 212 Heating High 800 222 471 Med 640 178 377 Low 530 147 312 Quiet 360 100 212 ARXG18KSLAP Cooling High 940 261 553 Med 750 208 441 Low 540 15...

Page 124: ... 450 125 265 ARXG12KLLAP Cooling High 650 181 383 Med 600 167 353 Low 550 153 324 Quiet 480 133 283 Heating High 650 181 383 Med 600 167 353 Low 550 153 324 Quiet 480 133 283 ARXG14KLLAP Cooling High 800 222 471 Med 700 194 412 Low 600 167 353 Quiet 480 133 283 Heating High 800 222 471 Med 700 194 412 Low 600 167 353 Quiet 480 133 283 ARXG18KLLAP Cooling High 940 261 553 Med 880 244 518 Low 820 22...

Page 125: ...3 h l s CFM ARXG22KMLB Cooling High 1 100 306 647 Med 910 253 536 Low 750 208 441 Quiet 580 161 341 Heating High 1 100 306 647 Med 910 253 536 Low 750 208 441 Quiet 580 161 341 117 7 4 Medium static pressure duct type 7 Airflow 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 126: ...iet 270 75 159 Heating High 770 214 453 Med 640 178 377 Low 520 144 306 Quiet 330 92 194 ASYG14KGTB Cooling High 770 214 453 Med 600 167 353 Low 450 125 265 Quiet 280 78 165 Heating High 800 222 471 Med 660 183 388 Low 520 144 306 Quiet 340 94 200 ASYG18KMTB Cooling High 980 272 577 Med 810 225 477 Low 640 178 377 Quiet 510 142 300 Heating High 1 020 283 600 Med 850 236 500 Low 640 178 377 Quiet 5...

Page 127: ... 270 75 159 Heating High 750 208 441 Med 610 169 359 Low 470 131 277 Quiet 330 92 194 ASYG12KMTB Cooling High 700 194 412 Med 560 156 330 Low 430 119 253 Quiet 270 75 159 Heating High 770 214 453 Med 640 178 377 Low 520 144 306 Quiet 330 92 194 ASYG14KMTB Cooling High 770 214 453 Med 600 167 353 Low 450 125 265 Quiet 280 78 165 Heating High 800 222 471 Med 660 183 388 Low 520 144 306 Quiet 340 94 ...

Page 128: ...gh 820 228 483 Med 660 183 388 Low 520 144 306 Quiet 340 94 200 ASYG07KETA ASYG07KETA B Cooling High 650 181 383 Med 540 150 318 Low 430 119 253 Quiet 270 75 159 Heating High 720 200 424 Med 580 161 341 Low 460 128 271 Quiet 330 92 194 ASYG09KETA ASYG09KETA B Cooling High 700 194 412 Med 560 156 330 Low 430 119 253 Quiet 270 75 159 Heating High 750 208 441 Med 610 169 359 Low 470 131 277 Quiet 330...

Page 129: ...G14KETA ASYG14KETA B Cooling High 770 214 453 Med 600 167 353 Low 450 125 265 Quiet 280 78 165 Heating High 800 222 471 Med 660 183 388 Low 520 144 306 Quiet 340 94 200 121 7 5 Wall mounted type 7 Airflow 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 130: ... Quiet 650 181 383 Heating High 840 233 494 Med 790 219 465 Low 710 197 418 Quiet 650 181 383 ABYG22KRTA Cooling High 900 250 530 Med 790 219 465 Low 710 197 418 Quiet 650 181 383 Heating High 900 250 530 Med 790 219 465 Low 710 197 418 Quiet 650 181 383 122 7 6 Ceiling type 7 Airflow 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 131: ...iet 270 75 159 AGYG12KVCA Cooling High 600 167 353 Med 490 136 288 Low 380 106 224 Quiet 270 75 159 Heating High 600 167 353 Med 510 142 300 Low 410 114 241 Quiet 270 75 159 AGYG14KVCA Cooling High 650 181 383 Med 520 144 306 Low 400 131 277 Quiet 270 75 159 Heating High 650 181 383 Med 540 150 318 Low 430 119 253 Quiet 270 75 159 123 7 7 Floor type 7 Airflow 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MUL...

Page 132: ...0 NC 40 NC 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 HIGH QUIET Model AUXG09KVLA Cooling Octave band sound pressure level dB 0 dB 0 00020 μbar Octave band center frequency Hz 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 NC 20 NC 40 NC 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 00020 μbar Octave band ...

Page 133: ... 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 HIGH QUIET Model AUXG14KVLA Cooling Octave band sound pressure level dB 0 dB 0 00020 μbar Octave band center frequency Hz 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 NC 20 NC 40 NC 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 00020 μbar Octave band center frequency Hz 0 ...

Page 134: ... 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Model AUXG22KVLA Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 QUIET NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 ...

Page 135: ... 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 HIGH QUIET Model ARXG09KSLAP Cooling 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Octave band sound pressure level dB 0 dB 0 00020 μbar Octave band center frequency Hz HIGH QUIET NC 20 NC 40 NC 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 Heating NC 20 NC 40 NC 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 HIGH QUIE...

Page 136: ...40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Model ARXG14KSLAP Cooling 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Octave band sound pressure level dB 0dB 0 00020 μbar Octave band center frequency Hz QUIET HIGH NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Heating 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Octave band sound pr...

Page 137: ...65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Heating 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Octave band sound pressure level dB 0dB 0 00020 μbar Octave band center frequency Hz QUIET HIGH NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 129 8 2 Mini duct type 8 Noise level curve 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 138: ...C 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 HIGH QUIET Model ARXG09KLLAP Cooling NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 QUIET HIGH Heating NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octave ba...

Page 139: ... 0 63 125 250 500 1 000 2 000 4 000 8 000 HIGH QUIET Model ARXG14KLLAP Cooling 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Octave band sound pressure level dB 0 dB 0 00020 μbar Octave band center frequency Hz NC 20 NC 40 NC 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 HIGH QUIET Heating 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Octave band sound pr...

Page 140: ...0 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 HIGH QUIET Heating NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 HIGH QUIET 132 8 3 Slim duct type 8 Noise level curve 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 141: ... NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET 133 8 4 Medium static pressure duct type 8 Noise level curve 4 5 UNIT MULTI SPLIT TYPE 4 5 UN...

Page 142: ... 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Model ASYG09KGTB Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequ...

Page 143: ...NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Model ASYG14KGTB Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80...

Page 144: ...NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Model ASYG22KMTB Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80...

Page 145: ... 30 NC 25 NC 20 NC 15 HIGH QUIET Models ASYG07KMTB ASYG07KMCC ASYG07KETA and ASYG07KETA B Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band ce...

Page 146: ...NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Models ASYG12KMTB ASYG12KMCC ASYG12KETA and ASYG12KETA B Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002...

Page 147: ...000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET 139 8 5 Wall mounted type 8 Noise level curve 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MUL...

Page 148: ... 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Model ABYG22KRTA Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequ...

Page 149: ...60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 QUIET Model AGYG12KVCA Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 HIGH NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequ...

Page 150: ...C 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 HIGH NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 QUIET 142 8 7 Floor type 8 Noise level curve 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 151: ...8 8 Sound level check point Compact cassette type Microphone Microphone 1 5 m 143 8 8 Sound level check point 8 Noise level curve 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 152: ...he static pressure as rating in this area Measuring duct Wall mounted type 0 8 m 1 m Microphone Microphone NOTE Detailed shape of the actual indoor unit might be slightly different from the one illustrated above Ceiling type Microphone Microphone 1 m 1 m 144 8 8 Sound level check point 8 Noise level curve 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 153: ... Floor type Microphone Microphone 1m 1m Airflow Airflow 145 8 8 Sound level check point 8 Noise level curve 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 154: ... ARXG18KLLAP 0 55 73 0 44 Medium static pressure duct ARXG22KMLB 1 00 94 0 60 1 5 26 Wall mounted ASYG07KGTB 0 25 23 0 20 1 5 26 ASYG09KGTB 0 30 27 0 24 ASYG12KGTB 0 30 27 0 24 ASYG14KGTB 0 37 33 0 29 ASYG18KMTB 0 44 38 0 35 ASYG22KMTB 0 49 47 0 39 ASYG24KMTB 0 55 62 0 44 ASYG07KMTB 0 25 23 0 20 ASYG09KMTB 0 30 27 0 24 ASYG12KMTB 0 30 27 0 24 ASYG14KMTB 0 38 33 0 30 ASYG07KMCC 0 25 23 0 20 ASYG09K...

Page 155: ...MCA Minimum Circuit Ampacity Maximum operating current Full load FLA Full Load Amperes Fan motor 147 9 Electrical characteristics 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 156: ...LA AUXG12KVLA AUXG14KVLA AUXG18KVLA AUXG22KVLA Mini duct ARXG07KSLAP Activate 135 15 C Fan motor stop Reset 105 15 C Fan motor restart ARXG09KSLAP ARXG12KSLAP ARXG14KSLAP ARXG18KSLAP Slim duct ARXG07KLLAP ARXG09KLLAP ARXG12KLLAP ARXG14KLLAP ARXG18KLLAP Activate 135 15 C Fan motor stop Reset 115 15 C Fan motor restart Medium static pressure duct ARXG22KMLB 148 10 Safety devices 4 5 UNIT MULTI SPLIT...

Page 157: ...10 C Fan motor stop Reset 100 10 C Fan motor restart ASYG07KMCC Activate 170 25 30 C Fan motor stop Reset 145 25 30 C Fan motor restart ASYG09KMCC ASYG12KMCC ASYG14KMCC ASYG07KETA ASYG07KETA B Activate 110 15 C Fan motor speed down Reset 110 15 C Fan motor speed recover 102 C Off ASYG09KETA ASYG09KETA B ASYG12KETA ASYG12KETA B ASYG14KETA ASYG14KETA B Activate 125 10 C Fan motor stop Reset 100 10 C...

Page 158: ...um static pressure duct types CN47 Ext out Terminal Ext in Indoor unit PCB External input and output Connector Input select Input signal External connect kit Optional parts External input Operation Stop Forced stop Terminal Dry contact Edge External output Operation status CN47 UTY XWZXZG Error status Indoor unit fan operation status External heater output 150 11 1 Compact cassette type Mini duct ...

Page 159: ...t cable with appropriate external dimension depending on the number of ca bles to be installed A twisted pair cable 22AWG should be used Maximum length of cable is 25 m Output voltage High DC 12 V 2 V Low 0 V Permissible current 50 mA For details refer to Combination of external input and output on page 152 When indicator etc are connected directly Example Function setting 60 is set to 00 1 2 CN47...

Page 160: ...n Stop Error status 10 60 10 Operation Stop Indoor unit fan operation status 11 60 11 Operation Stop External heater output NOTE Input of Operation Stop depends on the setting of function setting 46 00 Operation Stop mode 1 R C enabled 01 Setting prohibited 02 Forced stop 03 Operation Stop mode 2 R C disabled Input signal type Indoor unit Input signal type is only Edge Edge 152 11 1 Compact casset...

Page 161: ...setting External input Input signal Command 46 02 Terminal Off On Forced stop On Off Normal On Off Forced stop Normal Operation Stop Remote controller On On Indoor unit On Input NOTES When the forced stop is triggered indoor unit stops and Operation Stop operation by the re mote controller is restricted When forced stop function is used with forming a remote controller group connect the same equip...

Page 162: ...trol output function Function setting External output Output signal Command 60 00 CN47 Low High Operation High Low Stop The output is low when the unit is stopped Operation Stop High Low CN47 Indoor unit Error status Function setting External output Output signal Command 60 09 CN47 Low High Error High Low Normal The output is ON when an error is generated for the indoor unit Error Normal High Low ...

Page 163: ...ture Off On High Low Heater turns off as shown in diagram of heating temperature Other than Heating mode Error occurred On Off Forced thermo off Fan stop protection Specifications of the signal output performance are as shown as follows Example When set temperature Ts is set at 22 C And room temperature Tr increase above 12 C signal output is on And Tr increase above 21 C signal output is off And ...

Page 164: ...ut and output UTY XCSXZ2 Operation Stop CN313 CN314 Dry contact Apply voltage Edge Pulse Forced stop Forced thermostat off CN313 Edge Operation status CN310 Error status CN311 Indoor unit fan operation status CN312 NOTE KETA KETA B External input and output PCB cannot be used with Wireless LAN adapter simultaneously 156 11 2 Wall mounted type KGTB 18 24KMTB KETA and KETA B 11 External input and ou...

Page 165: ...es of connec tors cannot be used simultaneously Dry contact In case of internal power supply set the slide switch of SW301 to NON VOL side 1 2 3 Input 1 PCB Connected unit 1 2 3 Input 2 Connector CN313 Connector CN314 1 The switches can be used on the following condition DC 12 V to 24 V 1 mA to 15 mA Apply voltage In case of external power supply set the slide switch of SW301 to VOL side 1 2 3 Inp...

Page 166: ...setting 60 is set to 00 1 2 Connector CN310 LED 1 Operation status PCB Resistor Connected unit 1 2 Connector CN311 LED 2 Error status Resistor 1 2 Connector CN312 LED 3 Indoor unit fan operation status Resistor When connecting with a device equipped with a power supply Example Function setting 60 is set to 00 1 2 Connected device 1 Connector CN310 PCB Connected unit Relay Operation status 1 2 Conn...

Page 167: ...D Forced Thermostat OFF Not available Edge Mode Function setting External input and output PCB Rotary SW External output External input and output PCB CN310 CN311 CN312 0 1 60 00 1 Operation Stop Error status Indoor unit fan operation status 0 2 60 00 2 Error status Indoor unit fan operation status Not available 1 8 60 01 to 60 08 3 9 A Setting prohibited 9 60 09 B Operation Stop Indoor unit fan o...

Page 168: ... type edge or pulse can be switched by the DIP switch SW302 on the External input and out put PCB Pulse The width of pulse must be longer than 200 msec Edge 160 11 2 Wall mounted type KGTB 18 24KMTB KETA and KETA B 11 External input and output 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 169: ...On CN313 In the case of Pulse input Function setting Rotary SW on External input and output PCB External input Input signal Command 46 00 60 00 1 External input and output PCB CN313 Pulse Operation CN314 Pulse Stop On On Off Operation Stop Remote controller On Off Indoor unit CN313 CN314 NOTES The last command has priority The indoor units within the same remote controller group operates in the sa...

Page 170: ...External input Input signal Command 46 02 60 00 1 External input and output PCB CN313 Pulse Forced stop CN314 Pulse Normal On Off Operation Stop Remote controller On Off Forced stop Normal CN313 CN314 On On On Indoorunit NOTES When the forced stop is triggered indoor unit stops and Operation Stop operation by the re mote controller is restricted When forced stop function is used with forming a rem...

Page 171: ...ction setting Rotary SW on External input and output PCB External input Input signal Command 46 03 60 00 1 External input and output PCB CN313 Pulse Operation CN314 Pulse Stop R C disabled On On Off Operation Stop Remote controller On Off Indoor unit CN313 CN314 R C disabled Off On NOTE When Operation Stop mode 2 function is used with forming a remote controller group connect the same equipment to...

Page 172: ...ut signal Command 60 00 2 60 09 B 60 10 C External input and output PCB CN313 Off On Thermostat off On Off Normal operation On Off On Off Compressor Room temp Set temp Input 164 11 2 Wall mounted type KGTB 18 24KMTB KETA and KETA B 11 External input and output 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 173: ...mal The output is ON when an error is generated for the indoor unit Error Normal On Off CN311 312 Indoor unit Indoor unit fan operation status Function setting Rotary SW on External input and output PCB External output Output signal Command 60 00 1 External input and output PCB CN312 Off On Fan run On Off Fan stop Output signal Condition On The indoor unit fan is operating Low High Off The fan is ...

Page 174: ...should be separate from the power cable line Control input Operation Stop or Forced stop The air conditioner can be remotely operated by means of the following on site work Unit operation is started at the following contents by adding the contact input of a commercial on off switch to a connector on the external control PCB and turning it on Unit operation Initial setting after power is on Startin...

Page 175: ...unit When function setting is Forced stop mode Remote controller On On On Input signal Indoor unit Command Remote control operation invalidity On Off Operation Stop Forced stop Normal When function setting is Operation Stop mode 2 On Input Off Operation Indoor unit Stop R C disabled Remote controller On On Off NOTE When Operation Stop mode 2 function is used with forming a remote controller group ...

Page 176: ...put wire Communication kit UTY TWBXF2 For operating the external function the wall mounted type requires the communication kit in addi tion to the wire UTY XWZXZ5 168 11 3 Wall mounted type 07 14KMTB and KMCC 11 External input and output 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 177: ...ample Relay unit 1 2 Signal Relay power supply V Connector 10 m DC 24 V Make the distance from the PCB to the connected unit within 10 m Relay spec Max DC 24 V 10 mA to less than 500 mA On Off Operation Stop Indoor unit Output signal Optional part Part name Model name Exterior External connect kit UTY XWZXZ5 External output wire Communication kit UTY TWBXF2 For operating the external function the ...

Page 178: ...to the connected unit within 10 m Relay spec Max DC 24 V 10 mA to less than 500 mA On Off Error Normal Error status Output signal Optional part Part name Model name Exterior External connect kit UTY XWZXZ5 External output wire Communication kit UTY TWBXF2 For operating the external function the wall mounted type requires the communication kit in addi tion to the wire UTY XWZXZ5 170 11 3 Wall mount...

Page 179: ...nput 1 Edge Operation status Output 1 Output 2 Output 3 Error status Indoor unit status External heater output External input With using external input function some functions on this product can be controlled from an external device Operation Stop mode can be selected with function setting of indoor unit A twisted pair cable 22AWG should be used Maximum length of cable is 150 m The wire connectio...

Page 180: ...1 to NON VOL side 1 2 C Input 1 Input 2 PCB Connected unit 1 The switches can be used on the following condition DC 12 V to 24 V 1 mA to 15 mA Apply voltage In case of external power supply set the slide switch of SW1 to VOL side 1 2 C Input 1 Input 2 Power supply PCB Connected unit 1 The switches can be used on the following condition DC 12 V to 24 V 1 mA to 15 mA 2 Make the power supply DC 12 V ...

Page 181: ...d unit When connecting with a device equipped with a power supply Example Function setting 60 is set to 00 1 2 Connected device CN47 PCB Connected unit Relay Operation status External input and output PCB A twisted pair cable 22AWG should be used Permissible voltage and current DC 5 V to 30 V 3 A AC 30 V to 250 V 3 A For details refer to Chapter 11 4 3 Combination of external input and output on p...

Page 182: ... Thermostat OFF Not available Edge Mode Function setting External input and output PCB Rotary SW External output Indoor unit Output External input and output PCB CN47 Output 1 Output 2 Output 3 0 1 60 00 1 Operation Stop Operation Stop Error status Indoor unit fan operation status 0 2 60 00 2 Operation Stop Error status Indoor unit fan operation status External heater output 1 8 60 01 to 60 08 3 9...

Page 183: ...e input signal type can be selected Signal type edge or pulse can be switched by the DIP switch 2 SW2 on the External input and output PCB Edge Pulse The width of pulse must be longer than 200 msec 175 11 4 Ceiling type 11 External input and output 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 184: ...signal Command 46 00 60 00 1 External input and output PCB Input 1 Pulse Operation Input 2 Pulse Stop On On Off Operation Stop Remote controller On Off Indoor unit Input 1 Input 2 NOTES The last command has priority The indoor units within the same remote controller group operates in the same mode 176 11 4 Ceiling type 11 External input and output 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYP...

Page 185: ...ng Rotary SW of External input and output PCB External input Input signal Command 46 02 60 00 1 External input and output PCB Input 1 Pulse Forced stop Input 2 Pulse Normal On Off Operation Stop Remote controller On Off Forced stop Normal Input 1 Input 2 On On On Indoor unit NOTES When the forced stop is triggered indoor unit stops and Operation Stop operation by the re mote controller is restrict...

Page 186: ...controller On On Off In the case of Pulse input Function setting Rotary SW of External input and output PCB External input Input signal Command 46 03 60 00 1 External input and output PCB Input 1 Pulse Operation Input 2 Pulse Stop R C disabled On On Off Operation Stop Remote controller On Off Indoor unit Input 1 Input 2 R C disabled Off On NOTES When Operation Stop mode 2 function is used with for...

Page 187: ... Control output function Function setting Rotary SW of External input and output PCB External output Output signal Command 60 00 1 2 Output of indoor unit CN47 Low High Operation High Low Stop 60 00 1 External input and output PCB Output 1 Off On Operation 60 09 B 60 10 C On Off Stop 60 11 D The output is low when the unit is stopped Operation Stop High Low CN47 On Off Output 1 Indoor unit 179 11 ...

Page 188: ...unit fan operation status Function setting Rotary SW of External input and output PCB External output Output signal Command 60 10 C Output of indoor unit CN47 Low High Fan run High Low Fan stop 60 00 2 60 09 B 60 11 D External input and output PCB Output 2 Off On Fan run On Off Fan stop 60 00 1 Output 3 Off On Fan run On Off Fan stop Output signal Condition On The indoor unit fan is operating Low ...

Page 189: ...of heating temperature Other than Heating mode On Off Error occurred Forced thermo off Fan stop protection Specifications of the signal output performance are as shown as follows Example When set temperature Ts is set at 22 C And room temperature Tr increase above 12 C signal output is on And Tr increase above 21 C signal output is off And Tr decrease below 19 C signal output is on And Tr decrease...

Page 190: ...s product can be controlled from an external device Operation Stop mode can be selected with function setting of indoor unit A twisted pair cable 22AWG should be used Maximum length of cable is 150 m The wire connection should be separate from the power cable line Indoor unit Indoor unit functions such as Operation Stop can be done by using indoor unit connectors 1 2 3 Connector CN14 CN15 PCB Conn...

Page 191: ...1 5 3 Combination of external input and output on page 184 When indicator or other components are connected directly Example Function setting 60 is set to 00 1 2 Connector CN20 CN21 CN22 CN23 LED PCB Resistor Connected unit When connecting with a device equipped with a power supply Example Function setting 60 is set to 00 1 2 Connected device Connector CN20 CN21 CN22 CN23 PCB Connected unit Relay ...

Page 192: ...nit CN20 CN21 CN22 CN23 0 60 00 Operation Stop Error status Indoor unit fan operation status External heater output 9 60 09 Error status Operation Stop Indoor unit fan operation status External heater output 10 60 10 Indoor unit fan operation status Operation Stop Error status External heater output 11 60 11 External heater output Operation Stop Indoor unit fan operation status Error status NOTE I...

Page 193: ...peration Stop Remote controller On Off Indoor unit On CN15 When function setting is Forced stop mode In the case of Edge input Mode Function setting External input Input signal Command 0 46 02 Input of indoor unit CN14 Off On Forced stop On Off Normal 60 00 CN15 Off On Forced stop On Off Normal On Off Forced stop Normal Operation Stop Remote controller On On Indoor unit On CN15 185 11 5 Floor type...

Page 194: ...gnal Command 0 46 03 Input of indoor unit CN14 Off On Operation On Off Stop R C disabled 60 00 CN15 Off On Operation On Off Stop R C disabled On CN15 Off Operation Indoor unit Stop R C disabled Remote contoller On On Off 186 11 5 Floor type 11 External input and output 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 195: ...topped Operation Stop High Low CN15 On Off CN20 Indoor unit Error status Mode Function setting External output Output signal Command 9 60 09 Output of indoor unit CN15 Low High Error High Low Normal 0 60 00 CN21 Off On Error On Off Normal The output is ON when an error is generated for the indoor unit Error Normal High Low CN15 On Off CN21 Indoor unit 187 11 5 Floor type 11 External input and outp...

Page 196: ...ernal factor such as the outdoor temperature change signal is output to tell the attainment status of set point Mode Function setting External output Output signal Command 12 60 12 Outputof indoor unit CN15 On Off Normal Off On Set point attainment Output signal Condition Off Reached the set point Tr Tsα 0 5 C On Unreached the set point Tr Tsα 2 5 C However even if the set point unreached the sign...

Page 197: ...le of heating device Floor heating device On Off WARNING Design and install external heater appropriately with considering its protection Inappropriate designing and installation of external heater may cause a fire by emitted heat from the external heater Fujitsu General Ltd is not responsible for inappropriate designing or installation of external heating device 189 11 5 Floor type 11 External in...

Page 198: ...Ts 1 C Tr Ts Tr Ts Thon 3 C Tr Ts 10 C Tr Ts 12 C Tr Room temperature Ts Set temperature Thon Heater on temperature Tr Ts 1 C Tr Ts Tr Ts Thon 3 C Tr Ts 12 C Tr Room temperature Ts Set temperature Thon Heater on temperature Off Off On A Tr Ts 10 C When room temperature stays in this zone for a specific time auxiliary heater is turned on For details refer to function number 71 Example When set temp...

Page 199: ...g group control system some functions may no longer be available 1 Connect up to 16 indoor units in a system A B C D E I U I U I U I U Remote controller A B C D E Remote controller cable Wiring length limitation A B C D E 500 m Example of wiring method 1 2 R W Remote controller cable Bus wire Remote controller Indoor unit 1 Indoor unit 2 Indoor unit 3 Indoor unit 4 Example of wiring method 1 2 R W...

Page 200: ...efer to Remote con troller address setting in Contents of function setting on page 268 NOTES Do not use the same setting value Setting is reflected after the power is turned on again Also set the R C address for the remote controller For details refer to the remote controller installation manual NOTE In manual setting connect up to 15 indoor units in a system RC AD 01 RC AD 02 RC AD 03 RC AD 04 Re...

Page 201: ...n ON OFF button SLEEP button MODE button FAN button RESET button CLOCK ADJUST button TEST RUN button ECONOMY button NOTE Functions may differ by type of the indoor unit For details refer to the operation manual Display panel Mode indicator LOW NOISE mode indicator Clock and Timer indicator SEND indicator Temperature indicator Fan speed indicator Swing indicator Transmit indicator 193 13 1 Wireless...

Page 202: ...n FAN button RESET button CLOCK ADJUST button TEST RUN button ECONOMY button NOTE Functions may differ by type of the indoor unit For details refer to the operation manual Display panel Mode indicator LOW NOISE mode indicator Clock and Timer indicator SEND indicator Temperature indicator Fan speed indicator Swing indicator Transmit indicator To facilitate explanation the accompanying illustration ...

Page 203: ... unit For details refer to the operation manual Display panel Mode indicator Clock and Timer indicator LOW NOISE mode indicator Transmit indicator Temperature indicator Fan speed indicator Swing indicator To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the c...

Page 204: ...g 124 without batteries Holder Unit mm 48 5 5 5 26 2 69 3 6 5 Front View Side View Bottom View Ø 3 5 Hole 150 106 8 Hole 3 5 2 R Size H W D mm 150 69 3 26 2 Weight g 27 196 13 1 Wireless remote controller AR REW4E AR REM4E and AR REB1E 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 205: ...Functions may differ by type of the indoor unit For details refer to the operation manual Display panel Mode indicator LOW NOISE mode indicator Clock and Timer indicator SEND indicator Temperature indicator Fan speed indicator Swing indicator Transmit indicator To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actual operation however the dis...

Page 206: ... 17 Weight g 125 without batteries Holder Unit mm 48 5 5 5 26 2 69 3 6 5 Front View Side View Bottom View Ø 3 5 Hole 150 106 8 Hole 3 5 2 R Size H W D mm 150 69 3 26 2 Weight g 27 198 13 2 Wireless remote controller AR REW2E 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 207: ...Functions may differ by type of the indoor unit For details refer to the operation manual Display panel Mode indicator Clock and Timer indicator SEND indicator Temperature indicator Fan speed indicator Swing indicator Transmit indicator LOW NOISE mode indicator To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actual operation however the dis...

Page 208: ... 17 Weight g 124 without batteries Holder Unit mm 48 5 5 5 26 2 69 3 6 5 Front View Side View Bottom View Ø 3 5 Hole 150 106 8 Hole 3 5 2 R Size H W D mm 150 69 3 26 2 Weight g 27 200 13 3 Wireless remote controller AR REM7E 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 209: ...may differ by type of the indoor unit For details refer to the operation manual Display panel Mode indicator Clock and Timer indicator Fan speed indicator Swing indicator Temperature indicator Transmit indicator To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate t...

Page 210: ...ght g 124 without batteries Holder Unit mm 48 5 5 5 26 2 69 3 6 5 Front View Side View Bottom View Ø 3 5 Hole 150 106 8 Hole 3 5 2 R Size H W D mm 150 69 3 26 2 Weight g 27 202 13 4 Wireless remote controller UTY LNTY Optional part 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 211: ...may differ by type of the indoor unit For details refer to the operation manual Display panel Mode indicator Clock and Timer indicator Fan speed indicator Swing indicator Temperature indicator Transmit indicator To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate t...

Page 212: ...ithout batteries Holder Unit mm 48 5 5 5 26 2 69 3 6 5 Front View Side View Bottom View Ø 3 5 Hole 150 106 8 Hole 3 5 2 R Size H W D mm 150 69 3 26 2 Weight g 27 204 13 5 IR receiver kit with Wireless remote controller UTY LBTYM Optional part 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 213: ... 2 17 57 4 13 6 145 22 9 118 4 60 72 4 8 3 5 57 6 Side view Rear view Size H W D mm 145 90 30 Weight g 150 205 13 5 IR receiver kit with Wireless remote controller UTY LBTYM Optional part 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 214: ...ELETE button Deletes the weekly timer schedule k TIMER SET button Sets the date hour minute and on off time l Vertical airflow direction and swing button Push for 2 seconds to change the swing mode m Horizontal airflow direction and swing but ton Push for 2 seconds to change the swing mode n FILTER RESET button o Operation lamp Lights during operation and when the timer is on p Timer and clock ind...

Page 215: ...ing 1 remote controller Remote controller 1 Red 12 V 2 White Signal 3 Black COM Indoor unit Remote controller 1 2 3 1 2 3 G G 2 remote controllers Remote controllers 1 Red 12 V 2 White Signal 3 Black COM Primary Secondary Indoor unit 1 2 3 1 2 3 1 2 3 Remote controller G G G 207 13 6 Wired remote controller UTY RNNYM Optional part 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT...

Page 216: ...ries by the type of the connected indoor unit When connecting to terminal block for Compact cassette Slim duct and Mini duct types Connect the end of remote controller cable directly to the exclusive terminal block PCB M4 screw Terminal block Remote controller cable Remote controller terminal block Outdoor unit or Power supply terminal block or Remote controller terminal block NOTE It may be faile...

Page 217: ...in 20 mm Remote controller cable Connecting cable White Red White Red Black Insulated connection Black 2 Connect the remote controller cable Connect the cable made in step 1 to the terminal 1 of optional Communication kit Connect the cable from the terminal 2 of Communication kit to the indoor unit PCB Remote controller cable Connecting cable Terminal 1 Terminal 2 Communication kit Indoor unit PCB...

Page 218: ...ns Used to select setting items during the setting item selec tion screen is displayed g MENU button Used to display the setting item selection screen h MODE button Each time the button is pressed operation mode switches as follows Auto Cool Dry Fan Heat i On Off button Starts or stops the operation NOTE On Off button cannot be operated at screens other than the Monitor mode screen j Display panel...

Page 219: ...r Indoor unit Y1 Y1 Y2 Y2 Y3 2 remote controllers When there is a functional grounding Remote controller Remote controller Y1 Y1 Y2 Y2 Y1 Y2 Y3 Indoor unit Group control When there is a functional grounding Remote controller Indoor units Y2 Y2 Y2 Y2 Y2 Y3 Y3 Y3 Y3 Y1 Y1 Y1 Y1 Y1 NOTE Group connection with Polar 3 wired remote controller is not allowed 211 13 7 Wired remote controller UTY RLRY Opti...

Page 220: ...ted pair Use sheathed PVC cable Installation Connect the end of remote controller cable directly to the exclusive terminal block Terminal block Indoor unit PCB Functional earthing If necessary Remote controller cable Non polar Y1 Y2 TO REMOTE CONTROL UNIT Ex IN Y3 1 2 NOTES Layout of terminal block and PCB is varies depending on the type of indoor unit Operation may fail if it is connected to the ...

Page 221: ... with backlight b Screen switch button Left c Menu button d Cancel button e Cursor button f Screen switch button Right g Power indicator h On off button i Enter button 213 13 8 Wired remote controller UTY RVNYM Optional part 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 222: ...troller 1 2 3 1 2 3 2 remote controllers Remote controllers 1 Red 12 V 2 White Signal 3 Black COM Primary Secondary Indoor unit 1 2 3 1 2 3 1 2 3 Remote controller Controller combination As for the combined usage of the controller refer to following figures Good UTY RVNYM UTY RNNYM UTY RVNYM UTY RSNYM Indoor unit UTY RVNYM SET TEMP START STOP Indoor unit Indoor unit UTY RVNYM 214 13 8 Wired remote...

Page 223: ... 120 21 3 Weight g 220 Wiring specifications Use Cable size Wire type Remarks Remote controller cable 0 33 mm2 Polar 3 core Use sheathed PVC cable 215 13 8 Wired remote controller UTY RVNYM Optional part 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 224: ... the case can be inserted Installation procedures 1 Process the remote controller cable 8 8 8 30 45 55 Unit mm 1 12V Red 2 Signal White 3 COM Black 2 Insert the flat blade screwdriver and twist it slightly to separate the front case and rear case 216 13 8 Wired remote controller UTY RVNYM Optional part 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 225: ...emote controller cable b Put a remote controller cable through the back hole of the rear case of the main body c Fix the rear case by securing it with attached screws 2 places When routing the cable on wall a Cut off the cable guide of the front case with using a knife or a nipper b Deburr the edge of the cable guide c Fix the rear case by securing it with attached screws 2 places 217 13 8 Wired r...

Page 226: ...le sheath Hole for cable tie 2 mm Good Prohibited To avoid an excessive tension or pressure to the terminal block fix the remote controller cable with the cable tie properly CAUTION Be careful to avoid breaking the cable by over tightening the cable tie When connecting the remote controller cables do not over tighten the screws 218 13 8 Wired remote controller UTY RVNYM Optional part 13 Remote con...

Page 227: ...indoor unit When connecting to terminal block for Compact cassette Slim duct and Mini duct types Connect the end of remote controller cable directly to the exclusive terminal block PCB M4 screw Terminal block Remote controller cable Remote controller terminal block Outdoor unit or Power supply terminal block or Remote controller terminal block NOTE It may be failed if it is connected to the outdoo...

Page 228: ...in 20 mm Remote controller cable Connecting cable White Red White Red Black Insulated connection Black 2 Connect the remote controller cable Connect the cable made in step 1 to the terminal 1 of optional Communication kit Connect the cable from the terminal 2 of Communication kit to the indoor unit PCB Remote controller cable Connecting cable Terminal 1 Terminal 2 Communication kit Indoor unit PCB...

Page 229: ...r d Touch panel display e Set temperature Operating temperature can be set f Remote controller group name g Mode Operation mode can be set h Status icons i Clock j Fan Fan speed can be set k Room temperature l Menu Various settings can be set m Status Status of the indoor unit and error can be checked NOTE Functions may differ by type of the in door unit For details refer to the opera tion manual ...

Page 230: ...r Indoor unit Y1 Y1 Y2 Y2 Y3 2 remote controllers When there is a functional grounding Remote controller Remote controller Y1 Y1 Y2 Y2 Y1 Y2 Y3 Indoor unit Group control When there is a functional grounding Remote controller Indoor units Y2 Y2 Y2 Y2 Y2 Y3 Y3 Y3 Y3 Y1 Y1 Y1 Y1 Y1 NOTE Group connection with Polar 3 wired remote controller is not allowed 222 13 9 Wired remote controller UTY RNRYZ Opt...

Page 231: ...s Use Cable size Wire type Remarks Remote controller cable 0 33 to 1 25 mm2 Non polar 2 core Twisted pair Use sheathed PVC cable Installation Connect the end of remote controller cable directly to the exclusive terminal block Terminal block Indoor unit PCB Functional earthing If necessary Remote controller cable Non polar Y1 Y2 TO REMOTE CONTROL UNIT Ex IN Y3 1 2 NOTES Layout of terminal block and...

Page 232: ...s the main power is on i Central control indicator Indicates when function is locked j Fan speed indicator Deletes the weekly timer schedule k Set temperature Indicates error history number in error code history dis play mode Indicates indoor unit address in address display mode l Operating mode indicator m Indicator Upper Indicates the error code in error code history display mode and in self dia...

Page 233: ... wiring 1 remote controller Remote controller 1 Red 12 V 2 White Signal 3 Black COM Indoor unit Remote controller 1 2 3 1 2 3 2 remote controllers Remote controllers 1 Red 12 V 2 White Signal 3 Black COM Primary Secondary Indoor unit 1 2 3 1 2 3 1 2 3 Remote controller 225 13 10 Simple remote controller UTY RSNYM Optional part 13 Remote controller 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYP...

Page 234: ...f wired remote controller varies by the type of the connected indoor unit When connecting to terminal block for Compact cassette Slim duct and Mini duct types Connect the end of remote controller cable directly to the exclusive terminal block PCB M4 screw Terminal block Remote controller cable Remote controller terminal block Outdoor unit or Power supply terminal block or Remote controller termina...

Page 235: ...n 20 mm Remote controller cable Connecting cable White Red White Red Black Insulated connection Black 2 Connect the remote controller cable Connect the cable made in step 1 to the terminal 1 of optional Communication kit Connect the cable from the terminal 2 of Communication kit to the indoor unit PCB Remote controller cable Connecting cable Terminal 1 Terminal 2 Communication kit Indoor unit PCB ...

Page 236: ... indicator k Remote controller address indicator l Status icons Mode mismatch Filter sign 5 Defrost operation Oil recovery operation Under maintenance Error Special state Conducting electricity Emergency stop Operation controlled Forced stop Remote controller sensor is enabled 5 Central controlled Setting temperature range is enabled Operation prohibited m Set temperature Indicates indoor unit add...

Page 237: ... unit Y1 Y1 Y2 Y2 Y3 2 remote controllers When there is a functional grounding Remote controller Remote controller Y1 Y1 Y2 Y2 Y1 Y2 Y3 Indoor unit Group control When there is a functional grounding Remote controller Indoor units Y2 Y2 Y2 Y2 Y2 Y3 Y3 Y3 Y3 Y1 Y1 Y1 Y1 Y1 NOTE Group connection with Polar 3 wired remote controller is not allowed 229 13 11 Simple remote controller UTY RSRY and UTY RH...

Page 238: ...ore Twisted pair Use sheathed PVC cable Installation Connect the end of remote controller cable directly to the exclusive terminal block Terminal block Indoor unit PCB Functional earthing If necessary Remote controller cable Non polar Y1 Y2 TO REMOTE CONTROL UNIT Ex IN Y3 1 2 NOTES Layout of terminal block and PCB is varies depending on the type of indoor unit Operation may fail if it is connected...

Page 239: ... settings Related components on the PCB and the applicable settings Component Setting content DIP switch SW100 1 Remote controller address setting 2 3 4 SW101 1 Drainage function setting 2 Auto louver grille setting 3 Fan delay setting Component location Components on the indoor unit main PCB used for the function settings are located as shown in the following figure SW100 1 2 3 4 SW101 1 2 3 231 ...

Page 240: ...4 OFF ON ON ON 15 ON ON ON ON 00 01 02 Remote controller address Indoor unit Remote controller SW101 Switch 1 Drainage function setting Switch 1 Drainage function Factory setting ON Disabled OFF Enabled SW101 Switch 2 Auto louver grille setting When Auto louver grille kit optional parts is attached set to Enabled Switch 2 Auto louver grille setting Factory setting ON Enabled OFF Disabled SW101 Swi...

Page 241: ...settings may be selected between the following two Function number or Setting number Settings will not be changed if invalid numbers or setting numbers are selected Preparation Before connecting the power supply of the indoor unit reconfirm following items Piping air tight test and vacuuming have been performed firmly There is no wiring mistake Then connect the power supply of the indoor unit Brea...

Page 242: ...details Switches between the setting number bottom line and function number top line The displayed number Increases and decreases Changes the display digits Transmits function setting Transmits function mode POWERFUL button SET TEMP button START STOP button RESET button MODE button NOTE The number of buttons varies by the remote controller model Function setting procedure 1 Connect the power suppl...

Page 243: ...olding down the POWERFUL and TEMP button press the RESET button POWERFUL TEMP RESET Function setting mode display 235 14 2 Indoor unit setting by wireless remote controller 14 Function settings 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 244: ... To return to the function number selection press the POWERFUL button again 5 Select the function number by pressing the or the button Each time the 10 C HEAT but ton is pressed it switches between the right digit and the left digit Change digit 6 Press the MODE button once to transmit the function mode information 236 14 2 Indoor unit setting by wireless remote controller 14 Function settings 4 5...

Page 245: ... after pressing MODE button For the function details refer to Chapter 14 5 Function details on page 268 8 Exit the function setting mode by pressing the RESET button RESET Setting up each indoor unit Repeat step from 1 to 8 to set up each indoor unit If the custom code is other than steps from 1 to 2 and 8 need to be performed 237 14 2 Indoor unit setting by wireless remote controller 14 Function ...

Page 246: ... the power supply and then recon necting it Record the latest configuration of the indoor unit function setting on a label and put the label on the unit so it can be used for after sales service operations Once the RESET button is pressed on the remote controller the operation mode will be set to the AUTO MODE Adjust the operation mode to either cooling or heating before starting the operation of ...

Page 247: ...ton to change the custom code between 4 Press the MODE button again to return to the clock display The custom code will be changed If no buttons are pressed within 30 seconds after the custom code is displayed the system returns to the original clock display In this case start again from step 1 The air conditioner custom code is set to A prior to shipment If you do not know the air conditioner cus...

Page 248: ... number Increases and decreases Changes the displayed digits Fixes function setting Transmits function mode POWERFUL button TEMP button Start Stop button RESET button MODE button Function setting procedure 1 Connect the power supply of the outdoor unit 2 To enter the function setting mode while holding down the POWERFUL and SET TEMP buttons press the RESET button POWERFUL SET TEMP RESET Function s...

Page 249: ...urn to the function number selection press the POWERFUL button again 5 Select the function number by pressing the or the button Each time the 10 C HEAT but ton is pressed it switches between the right digit and the left digit Change digit 6 Press the MODE button once to transmit the function mode information 2 short beeps 241 14 2 Indoor unit setting by wireless remote controller 14 Function setti...

Page 250: ... after pressing MODE button For the function details refer to Chapter 14 5 Function details on page 268 8 Exit the function setting mode by pressing the RESET button RESET Setting up each indoor unit Repeat step from 1 to 8 to set up each indoor unit If the custom code is other than steps from 1 to 2 and 8 need to be performed 242 14 2 Indoor unit setting by wireless remote controller 14 Function ...

Page 251: ... the power supply and then recon necting it Record the latest configuration of the indoor unit function setting on a label and put the label on the unit so it can be used for after sales service operations Once the RESET button is pressed on the remote controller the operation mode will be set to the AUTO MODE Adjust the operation mode to either cooling or heating before starting the operation of ...

Page 252: ...utton to change the custom code between 4 Press the MODE button again to return to the clock display The custom code will be changed If no buttons are pressed within 30 seconds after the custom code is displayed the system returns to the original clock display In this case start again from step 1 The air conditioner custom code is set to A prior to shipment If you do not know the air conditioner c...

Page 253: ...er top line The displayed number Increases and decreases Changes the displayed digits Fixes function setting Transmits function mode ECONOMY button TEMP button Start Stop button RESET button MODE button Function setting procedure 1 Connect the power supply of the outdoor unit 2 To enter the function setting mode while holding down the ECONOMY and SET TEMP buttons press the RESET button ECONOMY SET...

Page 254: ... To return to the function number selection press the ECONOMY button again 5 Select the function number by pressing the or the button Each time the 10 C HEAT but ton is pressed it switches between the right digit and the left digit Change digit 6 Press the MODE button once to transmit the function mode information 246 14 2 Indoor unit setting by wireless remote controller 14 Function settings 4 5 ...

Page 255: ...e is set no beep sound will be emitted 1 short beep NOTE Press button within 30 seconds after pressing MODE button For the function details refer to Chapter 14 5 Function details on page 268 8 Exit the function setting mode by pressing the RESET button RESET 247 14 2 Indoor unit setting by wireless remote controller 14 Function settings 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 256: ...r unit is turned off However setting function is effective after disconnecting the power supply and then recon necting it Record the latest configuration of the indoor unit function setting on a label and put the label on the unit so it can be used for after sales service operations Once the RESET button is pressed on the remote controller the operation mode will be set to the AUTO MODE Adjust the...

Page 257: ...utton to change the custom code between 4 Press the MODE button again to return to the clock display The custom code will be changed If no buttons are pressed within 30 seconds after the custom code is displayed the system returns to the original clock display In this case start again from step 1 The air conditioner custom code is set to A prior to shipment If you do not know the air conditioner c...

Page 258: ...ted between the following two Function number or Setting number Settings will not be changed if invalid numbers or setting numbers are selected This function cannot be used on the secondary units Preparation Before connecting the power supply of the indoor unit reconfirm following items Piping air tight test and vacuuming have been performed firmly There is no wiring mistake Then connect the power...

Page 259: ...etting Function setting procedure 1 Connect the power supply of the outdoor unit 2 Switch to the function setting mode To enter the function setting mode hold down the 3 buttons of SET TEMP SET TEMP and FAN at the same time for 5 seconds or longer 3 Select the function number by pressing the SET TIME or the SET TIME button 4 Select the setting number by pressing the SET TEMP or the SET TEMP button...

Page 260: ...cording to the procedure in step 2 Setting up each indoor unit Repeat the procedures from step 1 to 6 and set up the indoor units requiring function setting Resetting the power after setting up function of all indoor units NOTES If the reset is not performed function cannot be read correctly After all the functions have been set the circuit breaker needs to be switched off for at least 2 minutes A...

Page 261: ...ing have been performed firmly There is no wiring mistake 1 Connect the power supply 2 To activate the address setting mode hold down the three buttons of MENU and EN TER at the same time for 2 seconds or longer Menu 2 setting screen is displayed 3 Select the 13 in Menu 2 settings Then press the ENTER button 4 Pressing the or button select a remote controller address select the indoor unit you wan...

Page 262: ...indoor units requiring function setting Resetting the power after setting up function of all indoor units NOTES If the reset is not performed function cannot be read correctly After all the functions have been set the circuit breaker needs to be switched off for at least 2 minutes After the 2 minutes has passed power can be restored The set function is stored in the PCB and will remain in memory e...

Page 263: ...witch button Right simultaneously for 5 seconds to switch to Service screen Back Setting Service Mo 10 00AM Function setting Error history I U address verification Version Test run Back Setting Date and time Submenu 1 2 Monitor Screen Filter sign R C sensor control Room temp display Off Off Mo 10 00AM Select Function setting with pressing the Cursor button Up Down and press the Enter but ton Back ...

Page 264: ...dress No No Version Error history 00 30 01 5 Pressing the Enter button confirm the setting The data will be transferred to the indoor unit Cancel OK Function setting Mo 10 00AM R C Function Setting address No No Version Error history 00 30 01 Cancel OK Function setting Mo 10 00AM R C Function Setting address No No Version Error history 00 30 Cancel OK Function setting Mo 10 00AM R C Function Setti...

Page 265: ...ep 1 to 6 and set up the indoor units requiring function setting Resetting the power after setting up function of all indoor units NOTES If the reset is not performed function cannot be read correctly After all the functions have been set the circuit breaker needs to be switched off for at least 2 minutes After the 2 minutes has passed power can be restored The set function is stored in the PCB an...

Page 266: ...nc tion Setting screen is displayed Previous Page Back Next Page Page 2 3 Maintenance Test Run R C Address Setting Function Setting I U Address Setting 002 01 00 00 Address Function No Setting No Function Setting Back Setting Address setting mode initial display 3 Touch the Address on the Function Setting screen 002 01 00 00 Address Function No Setting No Function Setting Back Setting 4 Address sc...

Page 267: ...n All is chosen by 5 and different set up Setting No from two or more indoor units is displayed on Setting No 8 Setting screen of Setting No is displayed Set the Function No with or 01 002 01 30 Function Setting Cancel OK Address Function No Setting No Example Function number 30 Setting Number 01 When the OK is touched the Function Setting verification screen is displayed 259 14 3 Indoor unit sett...

Page 268: ...e procedure from step 1 to 6 and set up the indoor units requiring function setting Resetting the power after setting up function of all indoor units NOTES If the reset is not performed function cannot be read correctly After all the functions have been set the circuit breaker needs to be switched off for at least 2 minutes After the 2 minutes has passed power can be restored The set function is s...

Page 269: ...ted between the following two Function number or Setting number Settings will not be changed if invalid numbers or setting numbers are selected This function cannot be used on the secondary units Preparation Before connecting the power supply of the indoor unit reconfirm following items Piping air tight test and vacuuming have been performed firmly There is no wiring mistake Then connect the power...

Page 270: ... TEMP p and q button Switches the various numbers Function setting procedure 1 Connect the power supply of the outdoor unit 2 Switch to the function setting mode To enter the function setting mode hold down the 3 buttons of SET TEMP SET TEMP and FAN at the same time for 5 seconds or longer Function setting mode initial display 3 Press the FAN button The Function number indicator flashes Then press...

Page 271: ...ge 268 6 Exit the function setting mode by pressing the 3 buttons of SET TEMP SET TEMP and FAN at the same time for 5 seconds or longer After exiting the function setting mode the display returns to the normal mode Normal mode display If no button is pressed within 60 seconds after buttons mentioned above are pressed it will au tomatically exit the function setting mode If you exit the function se...

Page 272: ...set function is stored in the PCB and will remain in memory even when the power of in door unit is turned off However setting function is effective after disconnecting the power supply and then recon necting it Record the latest configuration of the indoor unit function setting on a label and put the label on the unit so it can be used for after sales service operations 264 14 4 Indoor unit settin...

Page 273: ...g mistake NOTE Set only one Master remote controller 1 Connect the power supply 2 With Monitor mode screen displayed press and hold the SET TEMP button and FAN button simultaneously for at least 2 seconds 3 The Menu 1 screen is displayed Press and hold the SET TEMP button at least 2 seconds Setting mode selection screen is displayed 4 Press the SET TEMP or SET TEMP button to select F1 Menu 2 F1 se...

Page 274: ...T TEMP or SET TEMP button Then press the button Select the 2 wire remote controller address Ex Select the 002 03 9 Set the function number with the SET TEMP or SET TEMP button Then press the button Function number 10 Set the setting number with the SET TEMP or SET TEMP button Then press the button Setting number 266 14 4 Indoor unit setting by simple remote controller 14 Function settings 4 5 UNIT...

Page 275: ...annot be read correctly After all the functions have been set the circuit breaker needs to be switched off for at least 2 minutes After the 2 minutes has passed power can be restored The set function is stored in the PCB and will remain in memory even when the power of in door unit is turned off However setting function is effective after disconnecting the power supply and then recon necting it Re...

Page 276: ...ng height 4 21 Static pressure 5 22 Outlet directions 6 26 Static pressure 7 28 Horizontal louver direction switching for dew condensation prevention 8 30 31 Room temperature control for indoor unit sensor 9 35 36 Room temperature control for wired remote controller sensor 10 40 Auto restart 11 42 Room temperature sensor switching 12 44 Remote controller custom code 13 46 External input control 14...

Page 277: ...te controller address in the order of 0 1 2 and 15 When different type of indoor units such as wall mounted type and cassette type cassette type and duct type or other combinations are connected using group control system some func tions may no longer be available 2 Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust ...

Page 278: ...tu h models cannot be installed in high ceilings Do not change this setting 4 Static pressure for Medium static pressure duct type only Select the appropriate static pressure according to the installation conditions Function number Setting value Setting description Factory setting 21 00 Normal 01 High static pressure 1 02 High static pressure 2 03 High static pressure 3 5 Outlet directions for Com...

Page 279: ...cannot be set to 32 or more For slim duct type Function number Setting value Setting description Factory setting 26 00 0 Pa 01 10 Pa 02 20 Pa 03 30 Pa 04 40 Pa 05 50 Pa 06 60 Pa 07 70 Pa 08 80 Pa 09 90 Pa 31 Standard 25 Pa 7 Horizontal louver direction switching for dew condensation prevention for KE model in Wall mounted type only Automatically switches the position of the horizontal louver if th...

Page 280: ...is 26 C and the setting value is 03 1 0 C corrected temp will be 27 C 26 C 1 0 C The temperature correction values show the difference from the Standard setting 00 manufactur er s recommended value Function number Setting value Setting description Factory setting 30 For cooling 31 For heating 00 Standard setting 01 No correction 0 0 C 02 0 5 C More cooling Less heating 03 1 0 C 04 1 5 C 05 2 0 C 0...

Page 281: ...2 5 C 15 3 0 C 16 3 5 C 17 4 0 C 10 Auto restart Enables or disables automatic restart after a power interruption Function number Setting value Setting description Factory setting 40 00 Enable 01 Disable NOTE Auto restart is an emergency function such as for power outage etc Do not attempt to use this function in normal operation Be sure to operate the unit by remote controller or exter nal device...

Page 282: ... description Factory setting 48 00 Both 01 Wired remote controller 15 Indoor unit fan control for energy saving for cooling for other than Floor type Enables or disables the power saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation Function number Setting value Setting description Factory setting 49 00 Disable 01 Enable 02 Remote co...

Page 283: ... can be switched For details refer to External input and output Function number Setting value Setting description Factory setting 60 00 Operation status 01 08 Setting prohibited 09 Error status 10 Indoor unit fan operation status 11 External heater 275 14 5 Function details 14 Function settings 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 284: ...remote controller SW2 according to the following table Number of remote controller Primary unit Secondary unit Factory setting SW2 SW2 1 Normal OFF 2 Dual OFF ON 1 2 3 1 2 3 1 2 3 Indoor unit Remote controller cable Primary unit Secondary unit Remote controller SW4 Switching temperature unit F C Displayed temperature unit can be switched between Fahrenheit F and Celsius C SW4 Fahrenheit F Celsius ...

Page 285: ... When batteries are not used all of settings stored in memory will be deleted if there is a power failure SW6 Memory backup Factory setting OFF Disable ON Enable 277 14 6 Wired remote controller UTY RNNYM 14 Function settings 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 286: ...f there is a power failure SW1 Memory backup Factory setting OFF Disable ON Enable SW2 Dual remote controller setting Set the remote controller SW2 according to the following table Number of remote controller Primary unit Secondary unit Factory setting SW2 SW2 1 Normal OFF 2 Dual OFF ON 1 2 3 1 2 3 1 2 3 Indoor unit Remote controller cable Primary unit Secondary unit Remote controller 278 14 7 Wir...

Page 287: ...kup Factory setting OFF Disable ON Enable 14 9 Wired remote controller UTY RNRYZ DIP switch Memory backup setting Switch location Front case back side Set the DIP switch to ON OFF ON ON Dip switch setting SW1 Memory backup setting Set to ON to use batteries for the memory backup When batteries are not used all of settings stored in memory will be deleted if there is a power failure SW1 Memory back...

Page 288: ...e following table Number of remote controller Primary unit Secondary unit Factory setting SW2 SW2 1 Normal OFF 2 Dual OFF ON 1 2 3 1 2 3 1 2 3 Indoor unit Remote controller cable Primary unit Secondary unit Remote controller SW3 Switching temperature unit F C Displayed temperature unit can be switched between Fahrenheit F and Celsius C SW3 Fahrenheit F Celsius C Factory setting OFF C ON F 280 14 1...

Page 289: ... manual 1 Drain hose insulation 1 Operating manual CD ROM 1 Hose band 1 Installation manual 1 Coupler heat insulation large 1 Template Carton top 1 Coupler heat insulation small 1 M10 nut A with flange 4 Cable tie 2 M10 nut B with spring lock washer 4 Wire cramper 1 Drain hose 1 281 15 1 Compact cassette type 15 Accessories 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 290: ...ting manual CD ROM 1 Hose band 1 Installation manual 1 Drain hose insulation B 1 Installation template Carton top 1 Washer 8 Cable tie large 4 Coupler heat insulation large 1 Cable tie medium 3 Coupler heat insulation small 1 Filter small 2 Insulation For electrical wiring 2 282 15 2 Mini duct type 15 Accessories 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 291: ... 1 Installation manual 1 Drain hose insulation B 1 Installation template Carton top 1 Washer 8 Cable tie large 4 Coupler heat insulation large 1 Cable tie medium 3 Coupler heat insulation small 1 Filter large 2 Insulation For electrical wiring 2 283 15 2 Mini duct type 15 Accessories 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 292: ...n manual 1 Cable tie Small 3 Installation template 1 Drain hose 1 Washer 8 Hose band 1 Coupler heat insulation Large 1 Drain hose insulation B 1 Coupler heat insulation Small 1 Remote controller 1 Filter Small For 9 12 models 2 Remote controller cable 1 Filter Large For 18 models 2 Tapping screw 2 284 15 3 Slim duct type 15 Accessories 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 293: ...rating manual CD ROM 1 Cable tie small 1 Installation manual 1 Coupler heat insulation large 1 Hanger 4 Coupler heat insulation small 1 Drain hose insulation 1 M10 nut A with flange 4 Cable tie large 1 M10 nut B with spring lock washer 4 285 15 4 Medium static pressure duct type 15 Accessories 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 294: ...ating manual 1 Cloth tape 1 Operating manual CD ROM 1 Tapping screw large 5 Installation manual 1 Tapping screw small 2 Remote controller 1 Wall hook bracket 1 Battery 2 Filter holder 2 Remote controller holder 1 Air cleaning filters 1 286 15 5 Wall mounted type 15 Accessories 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 295: ...ing manual 1 Tapping screw large 5 Installation manual 1 Tapping screw small 2 Remote controller 1 Battery 2 Remote controller holder 1 Filter holder 2 Cloth tape 1 Air cleaning filters 1 Wall hook bracket 1 287 15 5 Wall mounted type 15 Accessories 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 296: ...ting manual 1 Cloth tape 1 Operating manual CD ROM 1 Tapping screw large 5 Installation manual 1 Tapping screw small 2 Remote controller 1 Wall hook bracket 1 Battery 2 Filter holder 2 Remote controller holder 1 Air cleaning filters 1 Template for pipe cover cutting 1 288 15 5 Wall mounted type 15 Accessories 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 297: ...stallation manual 1 Hose band 1 Template 1 Cable tie large 4 M10 nut A with flange 4 Cable tie small 1 M10 nut B with spring lock washer 4 Remote controller cable hole cap 1 Washer 8 Tapping screw White 6 Coupler heat insulation large 1 Tapping screw 3 Coupler heat insulation small 1 289 15 6 Ceiling type 15 Accessories 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 298: ...perating manual 1 Operating manual CD ROM 1 Installation manual 1 Cloth tape 1 Wall hook bracket 1 Tapping screws large 9 Remote controller 1 Tapping screws small 2 Battery 2 Air cleaning filters 1 Remote controller holder 1 290 15 7 Floor type 15 Accessories 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 299: ...e duct Wall mounted KG KMTB 18 24 model 07 14 model KMCC KE Ceiling Floor Indoor unit type Type Wired remote controller UTY RNNYM UTY RVNYM UTY RLRY UTY RNRYZ Compact cassette Mini duct Slim duct Medium static pressure duct Wall mounted KG 2 2 KMTB 18 24 model 2 2 07 14 model 1 1 KMCC 1 1 KE 2 2 Ceiling Floor 3 3 291 16 1 Controllers 16 Optional parts 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT...

Page 300: ... KG 2 2 KMTB 18 24 model 2 2 07 14 model 1 KMCC 1 KE 2 2 Ceiling Floor 3 3 Accessory Optional Not applicable 1 Optional Communication kit UTY TWBXF2 is necessary for the installation 2 Optional Communication kit UTY TWRXZ2 is necessary for the installation 3 Optional Communication kit UTY TWRXZ3 is necessary for the installation 292 16 1 Controllers 16 Optional parts 4 5 UNIT MULTI SPLIT TYPE 4 5 ...

Page 301: ...er AR REW2E AR REM7E Wired remote controller UTY RNNYM UTY RVNYM UTY RLRY UTY RNRYZ IR receiver kit with Wireless remote controller Simple remote controller UTY LBTYM UTY LBTYH UTY RSNYM UTY RSRY UTY RHRY 293 16 1 Controllers 16 Optional parts 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 302: ... 2 Cassette grille Lineup Indoor unit type Model Compact cassette UTG UFYF W Part Cassette grille UTG UFYF W 294 16 2 Cassette grille 16 Optional parts 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 303: ...tatic pressure duct Wall mounted KG KMTB 18 24 model 07 14 model KMCC KE Ceiling Floor Indoor unit type Type External switch controller Auto louver grille kit External connect kit UTY TERX UTD GXTA W UTD GXTB W UTY XWZX UTY XWZXZ5 UTY XWZXZG Compact cassette Mini duct Slim duct Medium static pressure duct Wall mounted KG 2 KMTB 18 24 model 2 07 14 model 1 KMCC 1 KE 2 Ceiling Floor 3 295 16 3 Other...

Page 304: ...del KMCC KE Ceiling Floor Indoor unit type Type Square flange Round flange Long life filter Drain pump unit UTD SF045T UTD RF204 UTD LF25NA UTZ PX1NBA Compact cassette Mini duct Slim duct Medium static pressure duct Wall mounted KG KMTB 18 24 model 07 14 model KMCC KE Ceiling Floor Accessory Optional Not applicable 1 Optional Communication kit UTY TWBXF2 is necessary for the installation 2 Optiona...

Page 305: ...AA External connect kit Model UTY XWZXZG External connect kit Model UTY XWZX External connect kit Model UTY XWZXZ5 x 1 x 1 x 1 x 2 External input and output PCB Model UTY XCSXZ2 Communication kit Model UTY TWRXZ2 Communication kit Model UTY TWBXF2 MODBUS converter Model UTY VMSX KNX converter Model UTY VKSX External switch controller Models UTY TERX 297 16 3 Others 16 Optional parts 4 5 UNIT MULTI...

Page 306: ...adapter Models UTY TFSXW1 Wireless LAN adapter Models UTY TFSXF2 Half concealed kit Models UTR STA Square flange Models UTD SF045T Round flange Models UTD RF204 Long life filter Models UTD LF25NA Drain pump unit Models UTZ PX1NBA 507 mm 239 mm 298 16 3 Others 16 Optional parts 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 307: ...installed where the installation height given in the installation manual is exceeded the temperature difference between the floor and ceiling of the room will be large and the heating effect will be poor Moreover even if the indoor unit is installed within the installation height a similar phenomena will occur when installed in a room in which the doors are opened and closed frequently and hot air...

Page 308: ...ntroller where it will not be directly exposed to sunlight or strong lighting When installation environment is quiet When the wall mounted type was installed in a bedroom living room or other quiet place the sound of the refrigerant flow may be sensed as noise and must be taken into account 1 Plan installation of a model with external expansion valve 2 Plan installation of a branch box farther fro...

Page 309: ...ing material locally purchased Small exposed part of copper pipe is desirable Fit tightly purpose is to cover the sealant Binding material Flare connection To indoor unit Heat insulation reinforcement material locally purchased Figure 17 2 Work method when reinforcing the heat insulation of on site piping 301 17 2 Points to remember when installing 17 Indoor unit installation precautions 4 5 UNIT ...

Page 310: ... 302 17 2 Points to remember when installing 17 Indoor unit installation precautions 4 5 UNIT MULTI SPLIT TYPE 4 5 UNIT MULTI SPLIT TYPE ...

Page 311: ...Part 2 OUTDOOR UNIT 4 UNITS TYPE MULTI SPLIT TYPE AOYG30KBTA4 ...

Page 312: ...eight Net kg 55 Gross 64 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 4 Gas Ø9 52 Ø3 8 2 Ø12 7 Ø1 2 2 Method Flare Pre charge length Total m 40 Maximum length Total 70 Maximum length Each 25 Minimum length Total 15 Minimum length Each 2 5 Maximum height difference between outdoor unit and each in door units 15 Maximum height difference between indoor units 10 Drain hose Material PP Tip diameter mm...

Page 313: ... Average A Pdesign Cooling kW 8 0 35 C Heating Average 6 5 10 C SEER Cooling kWh kWh 8 50 SCOP Heating Average 4 60 Annual energy consumption QCE kWh a 329 QHE Average 1 978 Sound power level Cooling HIGH dB A 63 Heating 66 305 1 Specifications OUTDOOR UNIT AOYG30KBTA4 OUTDOOR UNIT AOYG30KBTA4 ...

Page 314: ... 99 884 20 20 18 16 315 410 37 Drain port Ø42 Side view Side view Front view Top view Pitch of bolts for installation Bottom view Pitch of bolts for installation Airflow Unit mm 17 71 168 46 92 92 3 276 306 2 1 Model AOYG30KBTA4 2 Dimensions OUTDOOR UNIT AOYG30KBTA4 OUTDOOR UNIT AOYG30KBTA4 ...

Page 315: ...nstallation When the upper space is open Unit mm Obstacles at rear only Obstacles at rear and sides 100 or more 250 or more 100 or more 100 or more Obstacles at front Obstacles at front and rear 600 or more 600 or more 100 or more When an obstruction in the upper space Unit mm Obstacles at rear and above Obstacles at rear sides and above 100 or more Max 200 600 or more 250 or more 100 or more Max ...

Page 316: ...ace as shown in the following ex ample When an obstruction in the upper space When the upper space is open Unit mm Obstacles at rear only Obstacles at front only 200 or more 250 or more 1 000 or more 250 or more Obstacles at front and rear 200 or more 1 000 or more 250 or more When an obstruction in the upper space Unit mm Obstacles at rear and above 1 500 or more 200 or more 250 or more 250 or mo...

Page 317: ... unit in two stage where the drain water could freeze Otherwise the drainage from the upper unit may form ice and cause a malfunction of the lower unit When the outdoor temperature is 0 C or less do not use the accessory drain pipe and drain cap If the drain pipe and drain cap are used the drain water in the pipe may freeze in extremely cold climate For reverse cycle model only In area with heavy ...

Page 318: ...4 Refrigerant circuit 4 1 Model AOYG30KBTA4 C C Pressure switch CONDENSER 310 4 1 Model AOYG30KBTA4 4 Refrigerant circuit OUTDOOR UNIT AOYG30KBTA4 OUTDOOR UNIT AOYG30KBTA4 ...

Page 319: ...5 Wiring diagram 5 1 Model AOYG30KBTA4 311 5 1 Model AOYG30KBTA4 5 Wiring diagram OUTDOOR UNIT AOYG30KBTA4 OUTDOOR UNIT AOYG30KBTA4 ...

Page 320: ... 0 A 7 14 24 45 1 24 2 49 4 27 2 4 8 00 10 1 0 45 2 32 3 25 3 45 8 0 8 0 A 7 18 18 43 1 30 3 35 3 35 2 4 8 00 10 1 0 45 2 32 3 25 3 45 8 0 8 0 A 7 18 22 47 1 19 3 06 3 75 2 4 8 00 10 1 0 45 2 32 3 25 3 45 8 0 8 0 A 7 18 24 49 1 14 2 94 3 92 2 4 8 00 10 1 0 45 2 32 3 25 3 45 8 0 8 0 A 9 9 9 27 2 50 2 50 2 50 2 4 7 50 9 6 0 45 2 10 3 01 3 57 7 5 8 1 A 9 9 12 30 2 40 2 40 3 20 2 4 8 00 10 1 0 45 2 32...

Page 321: ...0 8 0 8 5 A 7 12 12 18 49 1 14 1 96 1 96 2 94 2 4 8 00 10 1 0 45 2 05 3 25 3 90 8 0 8 5 A 7 12 14 14 47 1 19 2 05 2 38 2 38 2 4 8 00 10 1 0 45 2 05 3 25 3 90 8 0 8 5 A 9 9 9 9 36 2 00 2 00 2 00 2 00 2 4 8 00 10 1 0 45 2 05 3 25 3 90 8 0 8 5 A 9 9 9 12 39 1 85 1 85 1 85 2 45 2 4 8 00 10 1 0 45 2 05 3 25 3 90 8 0 8 5 A 9 9 9 14 41 1 76 1 76 1 76 2 72 2 4 8 00 10 1 0 45 2 05 3 25 3 90 8 0 8 5 A 9 9 9...

Page 322: ...60 11 2 0 30 2 27 2 95 4 22 6 5 4 3 A 9 9 22 40 2 16 2 16 5 28 3 0 9 60 11 2 0 30 2 27 2 95 4 22 6 5 4 3 A 9 9 24 42 2 06 2 06 5 48 3 0 9 60 11 2 0 30 2 27 2 95 4 22 6 5 4 3 A 9 12 12 33 2 62 3 49 3 49 3 0 9 60 11 2 0 30 2 27 2 95 4 22 6 5 4 3 A 9 12 14 35 2 47 3 29 3 84 3 0 9 60 11 2 0 30 2 27 2 95 4 22 6 5 4 3 A 9 12 18 39 2 22 2 95 4 43 3 0 9 60 11 2 0 30 2 27 2 95 4 22 6 5 4 3 A 9 12 22 43 2 0...

Page 323: ...74 2 74 3 0 9 60 11 2 0 30 2 11 2 95 4 55 6 5 4 6 A 9 9 12 14 44 1 96 1 96 2 62 3 06 3 0 9 60 11 2 0 30 2 11 2 95 4 55 6 5 4 6 A 9 9 12 18 48 1 80 1 80 2 40 3 60 3 0 9 60 11 2 0 30 2 11 2 95 4 55 6 5 4 6 A 9 9 14 14 46 1 88 1 88 2 92 2 92 3 0 9 60 11 2 0 30 2 11 2 95 4 55 6 5 4 6 A 9 12 12 12 45 1 92 2 56 2 56 2 56 3 0 9 60 11 2 0 30 2 11 2 95 4 55 6 5 4 6 A 9 12 12 14 47 1 84 2 45 2 45 2 86 3 0 9...

Page 324: ... 2 11 11 1 2 13 5 0 7 9 1 98 8 9 2 02 9 4 2 03 10 1 2 05 10 8 2 08 11 1 2 09 10 0 7 9 2 11 8 9 2 14 9 4 2 16 10 1 2 19 10 8 2 21 11 1 2 22 15 0 7 9 2 00 8 9 2 04 9 4 2 05 10 1 2 08 10 8 2 10 11 1 2 11 20 0 7 9 1 89 8 9 1 93 9 4 1 94 10 1 1 97 10 8 1 99 11 1 2 00 25 0 7 9 2 29 8 9 2 33 9 4 2 35 10 1 2 38 10 8 2 40 11 1 2 42 30 0 7 9 2 74 8 9 2 79 9 4 2 82 10 1 2 85 10 8 2 88 11 1 2 90 35 0 7 9 3 18...

Page 325: ...18 8 9 3 24 9 4 3 26 10 1 3 30 10 8 3 34 11 1 3 35 40 0 6 6 2 69 7 4 2 74 7 8 2 76 8 4 2 79 8 9 2 82 9 2 2 84 46 0 5 2 2 20 5 9 2 24 6 2 2 25 6 6 2 28 7 1 2 31 7 3 2 32 38 10 0 7 9 1 94 8 9 1 97 9 4 1 99 10 1 2 01 10 8 2 03 11 1 2 05 0 0 7 9 2 02 8 9 2 05 9 4 2 07 10 1 2 09 10 8 2 11 11 1 2 13 5 0 7 9 1 98 8 9 2 02 9 4 2 03 10 1 2 05 10 8 2 08 11 1 2 09 10 0 7 9 2 11 8 9 2 14 9 4 2 16 10 1 2 19 10...

Page 326: ...9 3 18 8 9 3 24 9 4 3 26 10 1 3 30 10 8 3 34 11 1 3 35 40 0 6 6 2 69 7 4 2 74 7 8 2 76 8 4 2 79 8 9 2 82 9 2 2 84 46 0 5 2 2 20 5 9 2 24 6 2 2 25 6 6 2 28 7 1 2 31 7 3 2 32 30 10 0 7 9 1 94 8 9 1 97 9 4 1 99 10 1 2 01 10 8 2 03 11 1 2 05 0 0 7 9 2 02 8 9 2 05 9 4 2 07 10 1 2 09 10 8 2 11 11 1 2 13 5 0 7 9 1 98 8 9 2 02 9 4 2 03 10 1 2 05 10 8 2 08 11 1 2 09 10 0 7 9 2 11 8 9 2 14 9 4 2 16 10 1 2 1...

Page 327: ...1 70 9 5 1 72 9 8 1 73 0 0 7 0 1 70 7 9 1 73 8 3 1 75 8 9 1 77 9 5 1 79 9 8 1 80 5 0 7 0 1 67 7 9 1 70 8 3 1 72 8 9 1 74 9 5 1 76 9 8 1 77 10 0 7 0 1 78 7 9 1 81 8 3 1 83 8 9 1 85 9 5 1 87 9 8 1 88 15 0 7 0 1 69 7 9 1 72 8 3 1 74 8 9 1 76 9 5 1 78 9 8 1 79 20 0 7 0 1 60 7 9 1 63 8 3 1 64 8 9 1 66 9 5 1 68 9 8 1 69 25 0 7 0 1 94 7 9 1 97 8 3 1 99 8 9 2 01 9 5 2 03 9 8 2 04 30 0 7 0 2 32 7 9 2 36 8 ...

Page 328: ...1 46 0 1 64 0 72 1 86 0 82 1 96 0 94 2 10 1 06 2 24 1 16 2 31 1 33 Model AUXG12KVLA Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 2 22 3 81 2 53 4 02 2 91 4 30 3 27 4 60 3 57 4 74 4 10 5 0 3 37 2 22 3 81 2 53 4 02 2 91 4 30 3 27 4 60 3 57 4 74 4 10 0 0 3 37 2 22 3 81 2 53 4 02 2 91 ...

Page 329: ...door temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 6 01 3 65 6 79 4 16 7 15 4 80 7 66 5 39 8 19 5 89 8 44 6 75 5 0 6 01 3 65 6 79 4 16 7 15 4 80 7 66 5 39 8 19 5 89 8 44 6 75 0 0 6 01 3 65 6 79 4 16 7 15 4 80 7 66 5 39 8 19 5 89 8 44 6 75 5 0 6 01 3 65 6 79 4 16 7 15 4 80 7 66 5 39 8 19 5 89 8 44 6 75 10 0 6 01 3 ...

Page 330: ... 0 1 64 0 69 1 86 0 79 1 96 0 91 2 10 1 02 2 24 1 11 2 31 1 27 Model ARXG12KSLAP Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 5 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 0 0 3 37 2 16 3 81 2 46 4 02 2 83 4 3...

Page 331: ...3 37 5 66 3 88 6 06 4 36 6 48 4 77 6 68 5 47 20 0 4 75 2 96 5 37 3 37 5 66 3 88 6 06 4 36 6 48 4 77 6 68 5 47 25 0 4 75 2 96 5 37 3 37 5 66 3 88 6 06 4 36 6 48 4 77 6 68 5 47 30 0 4 75 2 96 5 37 3 37 5 66 3 88 6 06 4 36 6 48 4 77 6 68 5 47 35 0 4 75 2 96 5 37 3 37 5 66 3 88 6 06 4 36 6 48 4 77 6 68 5 47 40 0 3 93 2 03 4 44 2 31 4 68 2 66 5 02 2 99 5 36 3 27 5 53 3 75 46 0 3 11 1 27 3 52 1 45 3 71 ...

Page 332: ... 0 1 64 0 72 1 86 0 82 1 96 0 94 2 10 1 06 2 24 1 16 2 31 1 33 Model ARXG12KLLAP Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 2 27 3 81 2 59 4 02 2 99 4 30 3 35 4 60 3 67 4 74 4 20 5 0 3 37 2 27 3 81 2 59 4 02 2 99 4 30 3 35 4 60 3 67 4 74 4 20 0 0 3 37 2 27 3 81 2 59 4 02 2 99 4 3...

Page 333: ...ifference 0 m Outdoor unit Indoor unit Medium static pressure duct type Model ARXG22KMLB Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 6 01 3 96 6 79 4 51 7 15 5 19 7 66 5 83 8 19 6 38 8 44 7 31 5 0 6 01 3 96 6 79 4 51 7 15 5 19 7 66 5 83 8 19 6 38 8 44 7 31 0 0 6 01 3 96 6 79 4 51 7 15 ...

Page 334: ...46 0 1 64 0 61 1 86 0 69 1 96 0 79 2 10 0 89 2 24 0 98 2 31 1 12 Model ASYG12KGTB Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 5 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 0 0 3 37 1 90 3 81 2 16 4 02 2 49 4 ...

Page 335: ... 44 7 13 10 0 6 01 3 86 6 79 4 40 7 15 5 07 7 66 5 69 8 19 6 23 8 44 7 13 15 0 6 01 3 86 6 79 4 40 7 15 5 07 7 66 5 69 8 19 6 23 8 44 7 13 20 0 6 01 3 86 6 79 4 40 7 15 5 07 7 66 5 69 8 19 6 23 8 44 7 13 25 0 6 01 3 86 6 79 4 40 7 15 5 07 7 66 5 69 8 19 6 23 8 44 7 13 30 0 6 01 3 86 6 79 4 40 7 15 5 07 7 66 5 69 8 19 6 23 8 44 7 13 35 0 6 01 3 86 6 79 4 40 7 15 5 07 7 66 5 69 8 19 6 23 8 44 7 13 4...

Page 336: ...0 61 1 86 0 69 1 96 0 79 2 10 0 89 2 24 0 98 2 31 1 12 Model ASYG12KMTB Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 5 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 0 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 ...

Page 337: ...0 61 1 86 0 69 1 96 0 79 2 10 0 89 2 24 0 98 2 31 1 12 Model ASYG12KMCC Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 5 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 0 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 ...

Page 338: ...emperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 5 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 0 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 5 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50...

Page 339: ...ture Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 6 01 3 73 6 79 4 25 7 15 4 90 7 66 5 50 8 19 6 02 8 44 6 90 5 0 6 01 3 73 6 79 4 25 7 15 4 90 7 66 5 50 8 19 6 02 8 44 6 90 0 0 6 01 3 73 6 79 4 25 7 15 4 90 7 66 5 50 8 19 6 02 8 44 6 90 5 0 6 01 3 73 6 79 4 25 7 15 4 90 7 66 5 50 8 19 6 02 8 44 6 90 10 0 ...

Page 340: ... 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 20 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 25 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 30 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 35 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 40 0 2 79 1 48 3 15 1 69 3 32 1 94 3 56 2 18 3 80 2 38 3 92 2 73 46 0 2 21 0 93 2 50 1 06...

Page 341: ...2 98 10 6 3 04 15 0 10 0 11 8 2 44 11 5 2 50 11 2 2 55 10 9 2 60 10 6 2 65 20 0 15 0 11 8 2 06 11 5 2 10 11 2 2 14 10 9 2 19 10 6 2 23 24 0 18 0 11 8 1 87 11 5 1 91 11 2 1 94 10 9 1 98 10 6 2 02 45 15 0 16 0 6 1 2 96 6 0 3 02 5 9 3 08 5 7 3 14 5 6 3 20 10 0 11 0 7 6 3 24 7 5 3 31 7 3 3 38 7 1 3 45 6 9 3 51 5 0 7 0 9 1 3 13 8 9 3 20 8 7 3 26 8 4 3 33 8 2 3 39 0 0 2 0 10 7 3 35 10 4 3 42 10 2 3 49 9...

Page 342: ... 33 8 2 3 39 0 0 2 0 10 7 3 35 10 4 3 42 10 2 3 49 9 9 3 56 9 7 3 63 5 0 3 0 11 8 3 21 11 5 3 27 11 2 3 34 10 9 3 41 10 6 3 47 7 0 6 0 11 8 2 91 11 5 2 97 11 2 3 03 10 9 3 09 10 6 3 15 10 0 8 0 11 8 2 80 11 5 2 86 11 2 2 92 10 9 2 98 10 6 3 04 15 0 10 0 11 8 2 44 11 5 2 50 11 2 2 55 10 9 2 60 10 6 2 65 20 0 15 0 11 8 2 06 11 5 2 10 11 2 2 14 10 9 2 19 10 6 2 23 24 0 18 0 11 8 1 87 11 5 1 91 11 2 1...

Page 343: ... 2 2 55 10 9 2 60 10 6 2 65 20 0 15 0 11 8 2 06 11 5 2 10 11 2 2 14 10 9 2 19 10 6 2 23 24 0 18 0 11 8 1 87 11 5 1 91 11 2 1 94 10 9 1 98 10 6 2 02 28 15 0 16 0 6 1 2 96 6 0 3 02 5 9 3 08 5 7 3 14 5 6 3 20 10 0 11 0 7 6 3 24 7 5 3 31 7 3 3 38 7 1 3 45 6 9 3 51 5 0 7 0 9 1 3 13 8 9 3 20 8 7 3 26 8 4 3 33 8 2 3 39 0 0 2 0 10 7 3 35 10 4 3 42 10 2 3 49 9 9 3 56 9 7 3 63 5 0 3 0 11 8 3 21 11 5 3 27 11...

Page 344: ...gth 5 m Height difference 0 m Outdoor unit Indoor unit 2 or more indoor units should be connected The total ability of connected a indoor unit is from 25 000 Btu h up to 49 000 Btu h Input in the table are calculated based on the maximum indoor unit input combinations 336 6 3 Heating capacity 6 Capacity table OUTDOOR UNIT AOYG30KBTA4 OUTDOOR UNIT AOYG30KBTA4 ...

Page 345: ...3 20 3 12 3 04 2 97 5 0 7 0 3 90 3 81 3 71 3 62 3 53 0 0 2 0 4 59 4 48 4 37 4 26 4 15 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 68 4 56 15 0 10 0 5 04 4 92 4 80 4 68 4 56 20 0 15 0 5 04 4 92 4 80 4 68 4 56 24 0 18 0 5 04 4 92 4 80 4 68 4 56 Model AUXG14KVLA Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 1...

Page 346: ...3 0 8 93 8 71 8 50 8 29 8 08 7 0 6 0 8 93 8 71 8 50 8 29 8 08 10 0 8 0 8 93 8 71 8 50 8 29 8 08 15 0 10 0 8 93 8 71 8 50 8 29 8 08 20 0 15 0 8 93 8 71 8 50 8 29 8 08 24 0 18 0 8 93 8 71 8 50 8 29 8 08 NOTES TC Total Capacity kW Values mentioned in the table are based on the following conditions Pipe length 5 m Height difference 0 m Outdoor unit Indoor unit 338 6 3 Heating capacity 6 Capacity table...

Page 347: ... 0 3 78 3 69 3 60 3 51 3 42 24 0 18 0 3 78 3 69 3 60 3 51 3 42 Model ARXG12KSLAP Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 2 63 2 57 2 51 2 44 2 38 10 0 11 0 3 28 3 20 3 12 3 04 2 97 5 0 7 0 3 90 3 81 3 71 3 62 3 53 0 0 2 0 4 59 4 48 4 37 4 26 4 15 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 ...

Page 348: ...3 0 7 06 6 89 6 72 6 55 6 38 7 0 6 0 7 06 6 89 6 72 6 55 6 38 10 0 8 0 7 06 6 89 6 72 6 55 6 38 15 0 10 0 7 06 6 89 6 72 6 55 6 38 20 0 15 0 7 06 6 89 6 72 6 55 6 38 24 0 18 0 7 06 6 89 6 72 6 55 6 38 NOTES TC Total Capacity kW Values mentioned in the table are based on the following conditions Pipe length 5 m Height difference 0 m Outdoor unit Indoor unit 340 6 3 Heating capacity 6 Capacity table...

Page 349: ... 0 3 78 3 69 3 60 3 51 3 42 24 0 18 0 3 78 3 69 3 60 3 51 3 42 Model ARXG12KLLAP Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 2 63 2 57 2 51 2 44 2 38 10 0 11 0 3 28 3 20 3 12 3 04 2 97 5 0 7 0 3 90 3 81 3 71 3 62 3 53 0 0 2 0 4 59 4 48 4 37 4 26 4 15 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 ...

Page 350: ...ifference 0 m Outdoor unit Indoor unit Medium static pressure duct type Model ARXG22KMLB Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 4 66 4 55 4 44 4 33 4 22 10 0 11 0 5 80 5 67 5 53 5 39 5 25 5 0 7 0 6 91 6 74 6 58 6 41 6 25 0 0 2 0 8 12 7 93 7 73 7 54 7 35 5 0 3 0 8 93 8 71 8 50 8 29 8 08 7 0 6 0 8 93 8 71 8 50 8 29 8 08 10 0 8 0 8 93 8 71...

Page 351: ...15 0 3 78 3 69 3 60 3 51 3 42 24 0 18 0 3 78 3 69 3 60 3 51 3 42 Model ASYG12KGTB Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 2 63 2 57 2 51 2 44 2 38 10 0 11 0 3 28 3 20 3 12 3 04 2 97 5 0 7 0 3 90 3 81 3 71 3 62 3 53 0 0 2 0 4 59 4 48 4 37 4 26 4 15 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4...

Page 352: ... 39 5 25 5 0 7 0 6 91 6 74 6 58 6 41 6 25 0 0 2 0 8 12 7 93 7 73 7 54 7 35 5 0 3 0 8 93 8 71 8 50 8 29 8 08 7 0 6 0 8 93 8 71 8 50 8 29 8 08 10 0 8 0 8 93 8 71 8 50 8 29 8 08 15 0 10 0 8 93 8 71 8 50 8 29 8 08 20 0 15 0 8 93 8 71 8 50 8 29 8 08 24 0 18 0 8 93 8 71 8 50 8 29 8 08 Model ASYG24KMTB Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 4 ...

Page 353: ...3 69 3 60 3 51 3 42 24 0 18 0 3 78 3 69 3 60 3 51 3 42 Model ASYG12KMTB Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 2 63 2 57 2 51 2 44 2 38 10 0 11 0 3 28 3 20 3 12 3 04 2 97 5 0 7 0 3 90 3 81 3 71 3 62 3 53 0 0 2 0 4 59 4 48 4 37 4 26 4 15 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 68 4 56 1...

Page 354: ...3 69 3 60 3 51 3 42 24 0 18 0 3 78 3 69 3 60 3 51 3 42 Model ASYG12KMCC Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 2 63 2 57 2 51 2 44 2 38 10 0 11 0 3 28 3 20 3 12 3 04 2 97 5 0 7 0 3 90 3 81 3 71 3 62 3 53 0 0 2 0 4 59 4 48 4 37 4 26 4 15 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 68 4 56 1...

Page 355: ...ETA B Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 2 63 2 57 2 51 2 44 2 38 10 0 11 0 3 28 3 20 3 12 3 04 2 97 5 0 7 0 3 90 3 81 3 71 3 62 3 53 0 0 2 0 4 59 4 48 4 37 4 26 4 15 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 68 4 56 15 0 10 0 5 04 4 92 4 80 4 68 4 56 20 0 15 0 5 04 4 92 4 80 4 68 4 ...

Page 356: ...Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 4 66 4 55 4 44 4 33 4 22 10 0 11 0 5 80 5 67 5 53 5 39 5 25 5 0 7 0 6 91 6 74 6 58 6 41 6 25 0 0 2 0 8 12 7 93 7 73 7 54 7 35 5 0 3 0 8 93 8 71 8 50 8 29 8 08 7 0 6 0 8 93 8 71 8 50 8 29 8 08 10 0 8 0 8 93 8 71 8 50 8 29 8 08 15 0 10 0 8 93 8 71 8 50 8 29 8 08 20 0 15 0 8 93 8 71 8 50 8 29 8 08 24 ...

Page 357: ...5 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 68 4 56 15 0 10 0 5 04 4 92 4 80 4 68 4 56 20 0 15 0 5 04 4 92 4 80 4 68 4 56 24 0 18 0 5 04 4 92 4 80 4 68 4 56 Model AGYG14KVCA Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 3 07 3 00 2 93 2 85 2 78 10 0 11 0 3 82 3 73 3 64 3 55 3 46 5 0 7 0 4 55 4 ...

Page 358: ...988 0 974 0 960 0 946 0 1 003 1 000 0 992 0 978 0 964 0 950 Indoor unit is lower than outdoor unit 2 2 5 1 003 1 000 0 992 0 978 0 964 0 950 5 1 000 0 992 0 978 0 964 0 950 10 0 992 0 978 0 964 0 950 15 0 978 0 964 0 950 Heating Pipe length m 2 5 5 10 15 20 25 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 976 0 957 0 938 10 0 991 0 976 0 957 0 938 5 1 000 0 991 0 976 0 957 0...

Page 359: ...49 0 930 15 0 962 0 944 0 925 Indoor unit 12 000 Btu h Cooling Pipe length m 2 5 5 10 15 20 25 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 937 0 912 0 888 10 0 970 0 944 0 919 0 896 5 0 992 0 978 0 952 0 927 0 903 2 5 1 010 0 996 0 982 0 956 0 930 0 907 0 1 014 1 000 0 986 0 960 0 934 0 910 Indoor unit is lower than outdoor unit 2 2 5 1 014 1 000 0 986 0 960 0 934 0 910 5 ...

Page 360: ...35 0 910 15 0 957 0 930 0 905 Indoor unit 18 000 Btu h Cooling Pipe length m 2 5 5 10 15 20 25 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 968 0 961 0 954 10 0 982 0 976 0 969 0 962 5 0 992 0 990 0 984 0 977 0 970 2 5 0 998 0 996 0 994 0 988 0 981 0 974 0 1 002 1 000 0 998 0 992 0 985 0 978 Indoor unit is lower than outdoor unit 2 2 5 1 002 1 000 0 998 0 992 0 985 0 978 5 ...

Page 361: ...29 0 904 15 0 949 0 925 0 899 Indoor unit 24 000 Btu h Cooling Pipe length m 2 5 5 10 15 20 25 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 978 0 969 0 953 10 0 986 0 986 0 977 0 961 5 0 992 0 994 0 994 0 984 0 968 2 5 0 993 0 996 0 998 0 998 0 988 0 972 0 0 997 1 000 1 002 1 002 0 992 0 976 Indoor unit is lower than outdoor unit 2 2 5 0 997 1 000 1 002 1 002 0 992 0 976 5 ...

Page 362: ...gerant type R32 Refrigerant amount g 2 200 Refrigerant charge Total pipe length m 40 or less 50 60 70 Max 20 g m Additional charge amount g 0 200 400 600 354 8 1 Model AOYG30KBTA4 8 Additional charge calculation OUTDOOR UNIT AOYG30KBTA4 OUTDOOR UNIT AOYG30KBTA4 ...

Page 363: ...9 Airflow 9 1 Model AOYG30KBTA4 Cooling m3 h 2 400 l s 667 CFM 1 413 Heating m3 h 2 950 l s 820 CFM 1 736 355 9 1 Model AOYG30KBTA4 9 Airflow OUTDOOR UNIT AOYG30KBTA4 OUTDOOR UNIT AOYG30KBTA4 ...

Page 364: ... band sound pressure level dB 0 dB 0 0002 µbar 80 70 60 50 40 30 20 10 0 Octave band center frequency Hz 63 125 250 500 1 000 8 000 2 000 4 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 10 2 Sound level check point 1 m Microphone Microphone Rear Airflow Rear view Side view NOTE Detailed shape of the actual outdoor unit might be slightly different from the one illustrated ab...

Page 365: ...is the total current of the indoor unit and the outdoor unit 2 Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005 As the regulations of wire size and circuit breaker differ in each country or region select appropriate de vices complied to the regional standard 3 This is the wiring length in case voltage descent is less than 2 When the wiring length be comes longer ...

Page 366: ...essor protection Temperature thermistor Discharge temp Activate 110 C Compressor stop Reset After 7 minutes Compressor restart Temperature thermistor Compressor bottom temp Activate 108 C Compressor stop Reset After 3 minutes and 80 C or less Compressor restart Thermal protection program Outdoor temp Only in COOL or DRY mode Activate 20 C Compressor stop Reset 15 C Compressor restart 358 12 Safety...

Page 367: ... to performing the local settings Otherwise the compressor may fail Discharge any static electricity from your body before touching the push switches Never touch any terminal or pattern of any parts on the control board The positions of the switches on the outdoor unit control board are shown in the figure below MONITOR POWER ERROR MODE E F GRN RED A B C D CHECK SET 1 TEST RUN PUMP DOWN SET 2 ON O...

Page 368: ...R MODE A GRN RED B C D E F CHECK SET 1 TEST RUN PUMP DOWN SET 2 ON ON 1 2 3 DIP switch part LED display part SW1 SW2 1 Be sure to disconnect the power supply or turn off the breaker 2 Change the DIP switch setting according to the required setting 360 13 1 Setting methods 13 Function settings OUTDOOR UNIT AOYG30KBTA4 OUTDOOR UNIT AOYG30KBTA4 ...

Page 369: ...ory setting SW1 Push For the test run start and stop For the pump down start and stop SW2 Push For when check run function is activated For displaying the check run For resetting the Automatic wiring correction memory SET1 1 DIP For selecting cooling or heating during test operation OFF SET1 2 DIP For switching SW1 operation OFF SET1 3 DIP Prohibited OFF Do not change SET1 4 DIP For outdoor unit l...

Page 370: ... from the Central remote controller SET1 4 Setting Factory setting ON Continuous operation OFF Follow the Central remote controller settings SET2 1 Setting Factory setting ON Lower OFF Low 13 3 Changing the current limit function Change the outdoor unit current limit function by using this setting CAUTION When the current limited function is working cooling and heating capacity will decrease When ...

Page 371: ... unit open Gas pipe and liquid pipe 8 Is the power supply connected for more than 12 hours Restrictions applicable when performing the check run When the check run starts all indoor units connected to the outdoor unit will start to run automati cally During the check run you cannot check the operation of the indoor units separately After the check run check the operation of the indoor units separa...

Page 372: ...ff the power and check whether the indoor and outdoor communication lines are properly connected If there is no operation for 1 minute the LED will return to the original display POWER MODE LED ON Example When 4 indoor units A to D are connected MONITOR POWER ERROR MODE GRN RED A B C D E F 2 blink 3 Press the CHECK switch for 3 seconds or more again Check run is initiated When check run is initiat...

Page 373: ... C of the 4 units are reversed After the number of connected units are displayed B and C will light up in reverse MONITOR POWER ERROR MODE GRN RED A B C D E F 7 s 7 s 7 s 7 s 2 blink NOTES Automatic wiring correction will not be completed if the power supply is disconnected while dis playing the results To confirm the automatic wiring correction be sure to carry out step 5 If frost is formed on th...

Page 374: ...WER ERROR MODE GRN RED A B C D E F 2 blink 7 s 7 s 7 s 7 s Example of result table a Write a where the LEDs light up in the order that they light up A B C D E F 1 2 3 4 5 6 7 b Based on the results of step a record as follows Trace the dotted circle with a pen if multiple places light up A B C D E F Write the order from A to D in which the LEDs lit up inside the circle A B C D E F A B C D 366 14 1...

Page 375: ...y press the CHECK switch for 3 seconds or more After LEDs A to F have lit in turn all LEDs will light up indicating that the automatic wiring cor rection is completed 2 blink MONITOR POWER ERROR MODE GRN RED A B C D E F 6 Disconnect the power supply or turn off the breaker and wait 10 minutes then turn the power back on and perform test run NOTE If you do not disconnect the power supply or turn of...

Page 376: ...d You can compare the result that is recorded in step 4 of Chapter 14 1 3 Operating procedure for check run on page 364 If the automatic wiring correction is not completed the POWER MODE LED blinks twice and the MONITOR LED turns off Memory resetting of automatic wiring correction CAUTION When relocating the unit reset the memory beforehand or the unit may not function normally 1 Push the CHECK sw...

Page 377: ...the breaker before changing the DIP switch settings 1 Check the 3 way valves both at the liquid side and gas side are opened Confirm that the DIP switch SET1 2 is switched off 2 Set the operation mode to COOL or HEAT When switching the DIP switch SET1 1 between HEAT and COOL disconnect the power supply or turn off the circuit breaker beforehand SET 1 ON HEAT COOL SET1 1 In the first test run be su...

Page 378: ...ror occurs the error LED blinks at high speed MONITOR POWER ERROR MODE GRN RED A B C D E F blink High speed Error location LEDs A to F of MONITOR light and indicate the location of the error In the case of an overall error LEDs A to F of MONITOR do not light Example Coil error on indoor unit B MONITOR POWER ERROR MODE GRN RED A B C D E F blink High speed 370 14 2 Test run 14 Check and test OUTDOOR...

Page 379: ... MONITOR ERROR POWER MODE GRN RED A E D C B F Blink High speed 9 blink F 1 2 3 4 5 6 7 8 9 A C F J P U E D C For MONITOR A and B Display mode LED on Blink 0 5s Light on Number of blinking A 10 blink C 11 blink F 12 blink J 13 blink P 14 blink U 15 blink 371 14 3 Error code 14 Check and test OUTDOOR UNIT AOYG30KBTA4 OUTDOOR UNIT AOYG30KBTA4 ...

Page 380: ...ddle temp sensor error 73 3 Heat exchanger liquid temp sensor error 74 1 Outdoor temp sensor error 75 1 Suction gas temp sensor error 76 1 Valve sensor error 76 2 77 1 Heat sink temp sensor error 84 1 Current sensor 1 error stoppage permanently 86 1 Discharge pressure sensor error 86 4 High pressure switch 1 error 94 1 Trip detection 95 1 Compressor motor control error stoppage permanently 97 3 Fa...

Page 381: ...eaker is turned off when changing the DIP switch SET1 2 DIP switch SET 1 ON 3 To start operation push the PUMP DOWN switch SW1 for 3 seconds or push the switch after the power has been on for 3 minutes TEST RUN PUMP DOWN Push switch SW1 During pump down the LED POWER MODE blinks 3 times consecutively 3 blink MONITOR POWER ERROR MODE GRN RED A B C D E F NOTE If the PUMP DOWN switch SW1 is pushed wh...

Page 382: ...till continues open the liquid pipe valve Then per form the procedure again starting from step 3 To cancel the pump down operation push the PUMP DOWN switch SW1 again The indi cation of the LED returns to the original state which is before starting the pump down opera tion POWER MODE LED On The pump down may stop before completion due to an error To complete the pump down operation correct the err...

Page 383: ... AOYG30KBTA4 Part name Exterior Q ty Part name Exterior Q ty Installation manual 1 Adapter K mm in 12 70 1 2 to 9 52 3 8 2 Drain pipe 1 375 15 1 Model AOYG30KBTA4 15 Accessories OUTDOOR UNIT AOYG30KBTA4 OUTDOOR UNIT AOYG30KBTA4 ...

Page 384: ...measures Reference When installed near adjacent houses Perform installation work so that operating sound does not disturb the neighbors 1 Install a soundproof barrier 2 Change the installation site When there is the possibility of strong wind If the outdoor unit is exposed to strong wind capacity may drop frost may form during heating and operation may be stopped by high pressure rise In addition ...

Page 385: ...Part 3 OUTDOOR UNIT 5 UNITS TYPE MULTI SPLIT TYPE AOYG36KBTA5 ...

Page 386: ... 1 058 1 027 445 Weight Net kg 59 Gross 69 Connection pipe Size Liquid mm in Ø6 35 Ø1 4 5 Gas Ø9 52 Ø3 8 3 Ø12 7 Ø1 2 2 Method Flare Pre charge length Total m 40 Maximum length Total 75 Maximum length Each 25 Minimum length Total 15 Minimum length Each 2 5 Maximum height difference between outdoor unit and each in door units 15 Maximum height difference between indoor units 10 Drain hose Material ...

Page 387: ... Average A Pdesign Cooling kW 9 5 35 C Heating Average 7 0 10 C SEER Cooling kWh kWh 8 50 SCOP Heating Average 4 60 Annual energy consumption QCE kWh a 391 QHE Average 2 130 Sound power level Cooling HIGH dB A 65 Heating 68 379 1 Specifications OUTDOOR UNIT AOYG36KBTA5 OUTDOOR UNIT AOYG36KBTA5 ...

Page 388: ...15 410 37 Drain port Ø42 Side view Side view Front view Top view Pitch of bolts for installation Bottom view Pitch of bolts for installation Airflow Unit mm Side view Valve part 17 71 168 46 92 92 4 368 380 2 1 Model AOYG36KBTA5 2 Dimensions OUTDOOR UNIT AOYG36KBTA5 OUTDOOR UNIT AOYG36KBTA5 ...

Page 389: ...nstallation When the upper space is open Unit mm Obstacles at rear only Obstacles at rear and sides 100 or more 250 or more 100 or more 100 or more Obstacles at front Obstacles at front and rear 600 or more 600 or more 100 or more When an obstruction in the upper space Unit mm Obstacles at rear and above Obstacles at rear sides and above 100 or more Max 200 600 or more 250 or more 100 or more Max ...

Page 390: ...ace as shown in the following ex ample When an obstruction in the upper space When the upper space is open Unit mm Obstacles at rear only Obstacles at front only 200 or more 250 or more 1 000 or more 250 or more Obstacles at front and rear 200 or more 1 000 or more 250 or more When an obstruction in the upper space Unit mm Obstacles at rear and above 1 500 or more 200 or more 250 or more 250 or mo...

Page 391: ... unit in two stage where the drain water could freeze Otherwise the drainage from the upper unit may form ice and cause a malfunction of the lower unit When the outdoor temperature is 0 C or less do not use the accessory drain pipe and drain cap If the drain pipe and drain cap are used the drain water in the pipe may freeze in extremely cold climate For reverse cycle model only In area with heavy ...

Page 392: ...4 Refrigerant circuit 4 1 Model AOYG36KBTA5 C C Pressure switch CONDENSER 384 4 1 Model AOYG36KBTA5 4 Refrigerant circuit OUTDOOR UNIT AOYG36KBTA5 OUTDOOR UNIT AOYG36KBTA5 ...

Page 393: ...5 Wiring diagram 5 1 Model AOYG36KBTA5 385 5 1 Model AOYG36KBTA5 5 Wiring diagram OUTDOOR UNIT AOYG36KBTA5 OUTDOOR UNIT AOYG36KBTA5 ...

Page 394: ...6 0 30 2 07 2 70 3 63 7 5 8 2 A 9 9 12 30 2 50 2 50 3 50 3 0 8 50 10 7 0 30 2 46 3 27 3 45 8 5 8 1 A 9 9 14 32 2 50 2 50 4 00 3 0 9 00 11 0 0 30 2 68 3 45 3 36 9 0 8 1 A 9 9 18 36 2 38 2 38 4 74 3 0 9 50 11 0 0 30 2 91 3 45 3 27 9 5 8 0 A 9 9 22 40 2 14 2 14 5 22 3 0 9 50 11 0 0 30 2 91 3 45 3 27 9 5 8 0 A 9 9 24 42 2 04 2 04 5 42 3 0 9 50 11 0 0 30 2 91 3 45 3 27 9 5 8 0 A 9 12 12 33 2 50 3 50 3 ...

Page 395: ... 2 38 2 38 2 38 3 0 9 50 11 0 0 30 2 69 3 45 3 53 9 5 8 3 A 9 9 9 12 39 2 19 2 19 2 19 2 93 3 0 9 50 11 0 0 30 2 69 3 45 3 53 9 5 8 3 A 9 9 9 14 41 2 09 2 09 2 09 3 23 3 0 9 50 11 0 0 30 2 69 3 45 3 53 9 5 8 3 A 9 9 9 18 45 1 90 1 90 1 90 3 80 3 0 9 50 11 0 0 30 2 69 3 45 3 53 9 5 8 3 A 9 9 9 22 49 1 74 1 74 1 74 4 28 3 0 9 50 11 0 0 30 2 69 3 45 3 53 9 5 8 3 A 9 9 9 24 51 1 68 1 68 1 68 4 46 3 0 ...

Page 396: ...0 30 2 50 3 45 3 80 9 5 8 5 A 7 9 9 12 14 51 1 29 1 68 1 68 2 24 2 61 3 0 9 50 11 0 0 30 2 50 3 45 3 80 9 5 8 5 A 7 9 9 14 14 53 1 26 1 61 1 61 2 51 2 51 3 0 9 50 11 0 0 30 2 50 3 45 3 80 9 5 8 5 A 7 9 12 12 12 52 1 28 1 65 2 19 2 19 2 19 3 0 9 50 11 0 0 30 2 50 3 45 3 80 9 5 8 5 A 7 9 12 12 14 54 1 23 1 58 2 11 2 11 2 47 3 0 9 50 11 0 0 30 2 50 3 45 3 80 9 5 8 5 A 9 9 9 9 9 45 1 90 1 90 1 90 1 90...

Page 397: ...18 39 2 45 3 26 4 89 3 5 10 60 12 0 0 25 2 54 3 25 4 18 7 0 4 4 A 9 12 22 43 2 22 2 96 5 42 3 5 10 60 12 0 0 25 2 54 3 25 4 18 7 0 4 4 A 9 12 24 45 2 12 2 83 5 65 3 5 10 60 12 0 0 25 2 54 3 25 4 18 7 0 4 4 A 9 14 14 37 2 58 4 01 4 01 3 5 10 60 12 0 0 25 2 54 3 25 4 18 7 0 4 4 A 9 14 18 41 2 33 3 62 4 65 3 5 10 60 12 0 0 25 2 54 3 25 4 18 7 0 4 4 A 9 14 22 45 2 12 3 30 5 18 3 5 10 60 12 0 0 25 2 54...

Page 398: ...5 4 34 7 0 4 5 A 9 12 12 12 45 2 11 2 83 2 83 2 83 3 5 10 60 12 0 0 25 2 44 3 25 4 34 7 0 4 5 A 9 12 12 14 47 2 02 2 71 2 71 3 16 3 5 10 60 12 0 0 25 2 44 3 25 4 34 7 0 4 5 A 9 12 12 18 51 1 87 2 49 2 49 3 75 3 5 10 60 12 0 0 25 2 44 3 25 4 34 7 0 4 5 A 9 12 14 14 49 1 94 2 60 3 03 3 03 3 5 10 60 12 0 0 25 2 44 3 25 4 34 7 0 4 5 A 9 12 14 18 53 1 80 2 40 2 80 3 60 3 5 10 60 12 0 0 25 2 44 3 25 4 3...

Page 399: ...4 50 1 91 1 91 1 91 1 91 2 96 3 5 10 60 12 0 0 25 2 36 3 25 4 50 7 0 4 6 A 9 9 9 9 18 54 1 77 1 77 1 77 1 77 3 52 3 5 10 60 12 0 0 25 2 36 3 25 4 50 7 0 4 6 A 9 9 9 12 12 51 1 88 1 88 1 88 2 48 2 48 3 5 10 60 12 0 0 25 2 36 3 25 4 50 7 0 4 6 A 9 9 9 12 14 53 1 80 1 80 1 80 2 40 2 80 3 5 10 60 12 0 0 25 2 36 3 25 4 50 7 0 4 6 A 9 9 12 12 12 54 1 76 1 76 2 36 2 36 2 36 3 5 10 60 12 0 0 25 2 36 3 25 ...

Page 400: ...18 12 1 2 19 5 0 8 6 1 94 9 7 1 97 10 3 1 99 11 0 2 01 11 8 2 04 12 1 2 05 10 0 8 6 1 88 9 7 1 91 10 3 1 93 11 0 1 95 11 8 1 97 12 1 1 98 15 0 8 6 1 98 9 7 2 01 10 3 2 03 11 0 2 05 11 8 2 08 12 1 2 09 20 0 8 6 1 97 9 7 2 00 10 3 2 02 11 0 2 04 11 8 2 07 12 1 2 08 25 0 8 6 2 23 9 7 2 27 10 3 2 29 11 0 2 31 11 8 2 34 12 1 2 35 30 0 8 6 2 68 9 7 2 72 10 3 2 75 11 0 2 78 11 8 2 81 12 1 2 82 35 0 8 6 3...

Page 401: ...3 9 7 3 29 10 3 3 31 11 0 3 35 11 8 3 39 12 1 3 41 40 0 6 4 2 40 7 2 2 45 7 6 2 47 8 2 2 49 8 7 2 52 9 0 2 54 46 0 4 2 1 58 4 7 1 61 5 0 1 62 5 3 1 64 5 7 1 66 5 9 1 67 43 10 0 8 6 2 31 9 7 2 36 10 3 2 37 11 0 2 40 11 8 2 43 12 1 2 44 0 0 8 6 2 08 9 7 2 12 10 3 2 13 11 0 2 16 11 8 2 18 12 1 2 19 5 0 8 6 1 94 9 7 1 97 10 3 1 99 11 0 2 01 11 8 2 04 12 1 2 05 10 0 8 6 1 88 9 7 1 91 10 3 1 93 11 0 1 9...

Page 402: ...3 9 7 3 29 10 3 3 31 11 0 3 35 11 8 3 39 12 1 3 41 40 0 6 4 2 40 7 2 2 45 7 6 2 47 8 2 2 49 8 7 2 52 9 0 2 54 46 0 4 2 1 58 4 7 1 61 5 0 1 62 5 3 1 64 5 7 1 66 5 9 1 67 35 10 0 8 6 2 31 9 7 2 36 10 3 2 37 11 0 2 40 11 8 2 43 12 1 2 44 0 0 8 6 2 08 9 7 2 12 10 3 2 13 11 0 2 16 11 8 2 18 12 1 2 19 5 0 8 6 1 94 9 7 1 97 10 3 1 99 11 0 2 01 11 8 2 04 12 1 2 05 10 0 8 6 1 88 9 7 1 91 10 3 1 93 11 0 1 9...

Page 403: ...2 11 10 0 2 14 10 7 2 16 11 0 2 17 0 0 7 8 1 85 8 9 1 88 9 3 1 90 10 0 1 92 10 7 1 94 11 0 1 95 5 0 7 8 1 73 8 9 1 76 9 3 1 77 10 0 1 79 10 7 1 81 11 0 1 82 10 0 7 8 1 67 8 9 1 70 9 3 1 72 10 0 1 74 10 7 1 76 11 0 1 77 15 0 7 8 1 76 8 9 1 79 9 3 1 81 10 0 1 83 10 7 1 85 11 0 1 86 20 0 7 8 1 75 8 9 1 78 9 3 1 80 10 0 1 82 10 7 1 84 11 0 1 85 25 0 7 8 1 98 8 9 2 02 9 3 2 04 10 0 2 06 10 7 2 08 11 0 ...

Page 404: ...9 46 0 1 20 0 38 1 36 0 44 1 43 0 51 1 54 0 57 1 64 0 62 1 69 0 71 Model AUXG12KVLA Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 2 22 3 81 2 53 4 02 2 91 4 30 3 27 4 60 3 57 4 74 4 10 5 0 3 37 2 22 3 81 2 53 4 02 2 91 4 30 3 27 4 60 3 57 4 74 4 10 0 0 3 37 2 22 3 81 2 53 4 02 2 91 ...

Page 405: ...door temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 6 12 3 70 6 91 4 22 7 29 4 86 7 80 5 46 8 34 5 97 8 60 6 84 5 0 6 12 3 70 6 91 4 22 7 29 4 86 7 80 5 46 8 34 5 97 8 60 6 84 0 0 6 12 3 70 6 91 4 22 7 29 4 86 7 80 5 46 8 34 5 97 8 60 6 84 5 0 6 12 3 70 6 91 4 22 7 29 4 86 7 80 5 46 8 34 5 97 8 60 6 84 10 0 6 12 3 ...

Page 406: ... 0 1 20 0 37 1 36 0 42 1 43 0 49 1 54 0 55 1 64 0 60 1 69 0 68 Model ARXG12KSLAP Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 5 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 0 0 3 37 2 16 3 81 2 46 4 02 2 83 4 3...

Page 407: ...3 45 5 78 3 97 6 19 4 46 6 62 4 87 6 82 5 58 20 0 4 85 3 02 5 48 3 45 5 78 3 97 6 19 4 46 6 62 4 87 6 82 5 58 25 0 4 85 3 02 5 48 3 45 5 78 3 97 6 19 4 46 6 62 4 87 6 82 5 58 30 0 4 85 3 02 5 48 3 45 5 78 3 97 6 19 4 46 6 62 4 87 6 82 5 58 35 0 4 85 3 02 5 48 3 45 5 78 3 97 6 19 4 46 6 62 4 87 6 82 5 58 40 0 3 59 1 66 4 06 1 89 4 28 2 17 4 58 2 44 4 90 2 67 5 05 3 06 46 0 2 33 0 70 2 63 0 79 2 78 ...

Page 408: ... 0 1 20 0 38 1 36 0 44 1 43 0 51 1 54 0 57 1 64 0 62 1 69 0 71 Model ARXG12KLLAP Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 2 27 3 81 2 59 4 02 2 99 4 30 3 35 4 60 3 67 4 74 4 20 5 0 3 37 2 27 3 81 2 59 4 02 2 99 4 30 3 35 4 60 3 67 4 74 4 20 0 0 3 37 2 27 3 81 2 59 4 02 2 99 4 3...

Page 409: ...ifference 0 m Outdoor unit Indoor unit Medium static pressure duct type Model ARXG22KMLB Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 6 12 4 03 6 91 4 59 7 29 5 29 7 80 5 94 8 34 6 50 8 60 7 44 5 0 6 12 4 03 6 91 4 59 7 29 5 29 7 80 5 94 8 34 6 50 8 60 7 44 0 0 6 12 4 03 6 91 4 59 7 29 ...

Page 410: ...46 0 1 20 0 32 1 36 0 37 1 43 0 43 1 54 0 48 1 64 0 52 1 69 0 60 Model ASYG12KGTB Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 5 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 0 0 3 37 1 90 3 81 2 16 4 02 2 49 4 ...

Page 411: ... 60 7 27 10 0 6 12 3 93 6 91 4 48 7 29 5 16 7 80 5 80 8 34 6 34 8 60 7 27 15 0 6 12 3 93 6 91 4 48 7 29 5 16 7 80 5 80 8 34 6 34 8 60 7 27 20 0 6 12 3 93 6 91 4 48 7 29 5 16 7 80 5 80 8 34 6 34 8 60 7 27 25 0 6 12 3 93 6 91 4 48 7 29 5 16 7 80 5 80 8 34 6 34 8 60 7 27 30 0 6 12 3 93 6 91 4 48 7 29 5 16 7 80 5 80 8 34 6 34 8 60 7 27 35 0 6 12 3 93 6 91 4 48 7 29 5 16 7 80 5 80 8 34 6 34 8 60 7 27 4...

Page 412: ...0 32 1 36 0 37 1 43 0 43 1 54 0 48 1 64 0 52 1 69 0 60 Model ASYG12KMTB Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 5 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 0 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 ...

Page 413: ...0 32 1 36 0 37 1 43 0 43 1 54 0 48 1 64 0 52 1 69 0 60 Model ASYG12KMCC Outdoor temperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 5 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 0 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 ...

Page 414: ...emperature Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 5 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 0 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50 5 0 3 37 1 90 3 81 2 16 4 02 2 49 4 30 2 80 4 60 3 06 4 74 3 50...

Page 415: ...ture Indoor temperature CDB CWB 18 0 12 0 21 0 15 0 23 0 16 0 27 0 19 0 29 0 21 0 32 0 23 0 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10 0 6 12 3 80 6 91 4 33 7 29 4 99 7 80 5 60 8 34 6 13 8 60 7 02 5 0 6 12 3 80 6 91 4 33 7 29 4 99 7 80 5 60 8 34 6 13 8 60 7 02 0 0 6 12 3 80 6 91 4 33 7 29 4 99 7 80 5 60 8 34 6 13 8 60 7 02 5 0 6 12 3 80 6 91 4 33 7 29 4 99 7 80 5 60 8 34 6 13 8 60 7 02 10 0 ...

Page 416: ... 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 20 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 25 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 30 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 35 0 3 37 2 16 3 81 2 46 4 02 2 83 4 30 3 18 4 60 3 48 4 74 3 99 40 0 2 49 1 18 2 82 1 35 2 97 1 55 3 18 1 74 3 40 1 91 3 51 2 18 46 0 1 62 0 50 1 83 0 57...

Page 417: ...3 08 11 4 3 14 15 0 10 0 12 6 2 72 12 3 2 78 12 0 2 84 11 7 2 89 11 4 2 95 20 0 15 0 12 6 2 36 12 3 2 41 12 0 2 46 11 7 2 51 11 4 2 56 24 0 18 0 12 6 2 00 12 3 2 04 12 0 2 08 11 7 2 12 11 4 2 16 50 15 0 16 0 7 8 2 88 7 6 2 94 7 4 3 00 7 2 3 06 7 0 3 12 10 0 11 0 9 1 3 25 8 9 3 32 8 7 3 39 8 5 3 46 8 2 3 53 5 0 7 0 9 5 2 93 9 3 2 99 9 1 3 05 8 8 3 11 8 6 3 17 0 0 2 0 10 9 3 13 10 7 3 19 10 4 3 26 1...

Page 418: ... 11 8 6 3 17 0 0 2 0 10 9 3 13 10 7 3 19 10 4 3 26 10 2 3 32 9 9 3 39 5 0 3 0 12 6 3 29 12 3 3 36 12 0 3 42 11 7 3 49 11 4 3 56 7 0 6 0 12 6 3 13 12 3 3 20 12 0 3 26 11 7 3 33 11 4 3 39 10 0 8 0 12 6 2 90 12 3 2 96 12 0 3 02 11 7 3 08 11 4 3 14 15 0 10 0 12 6 2 72 12 3 2 78 12 0 2 84 11 7 2 89 11 4 2 95 20 0 15 0 12 6 2 36 12 3 2 41 12 0 2 46 11 7 2 51 11 4 2 56 24 0 18 0 12 6 2 00 12 3 2 04 12 0 ...

Page 419: ...3 05 8 6 3 11 0 0 2 0 10 9 3 07 10 7 3 13 10 4 3 19 10 2 3 26 9 9 3 32 5 0 3 0 12 6 3 22 12 3 3 29 12 0 3 36 11 7 3 43 11 4 3 49 7 0 6 0 12 6 3 07 12 3 3 14 12 0 3 20 11 7 3 26 11 4 3 33 10 0 8 0 12 6 2 85 12 3 2 91 12 0 2 97 11 7 3 02 11 4 3 08 15 0 10 0 12 6 2 67 12 3 2 73 12 0 2 78 11 7 2 84 11 4 2 89 20 0 15 0 12 6 2 32 12 3 2 36 12 0 2 41 11 7 2 46 11 4 2 51 24 0 18 0 12 6 1 96 12 3 2 00 12 0...

Page 420: ...0 8 2 63 10 5 2 68 10 3 2 73 15 0 10 0 11 3 2 37 11 1 2 42 10 8 2 47 10 5 2 52 10 3 2 57 20 0 15 0 11 3 2 05 11 1 2 10 10 8 2 14 10 5 2 18 10 3 2 22 24 0 18 0 11 3 1 73 11 1 1 77 10 8 1 81 10 5 1 84 10 3 1 88 NOTES TC Total Capacity kW IP Input Power kW Values mentioned in the table are based on the following conditions Power source of specifications 230 V Pipe length 5 m Height difference 0 m Out...

Page 421: ...3 54 3 46 3 37 3 28 5 0 7 0 3 83 3 74 3 65 3 56 3 47 0 0 2 0 4 38 4 28 4 18 4 07 3 97 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 68 4 56 15 0 10 0 5 04 4 92 4 80 4 68 4 56 20 0 15 0 5 04 4 92 4 80 4 68 4 56 24 0 18 0 5 04 4 92 4 80 4 68 4 56 Model AUXG14KVLA Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 1...

Page 422: ...3 0 8 95 8 73 8 52 8 31 8 09 7 0 6 0 8 95 8 73 8 52 8 31 8 09 10 0 8 0 8 95 8 73 8 52 8 31 8 09 15 0 10 0 8 95 8 73 8 52 8 31 8 09 20 0 15 0 8 95 8 73 8 52 8 31 8 09 24 0 18 0 8 95 8 73 8 52 8 31 8 09 NOTES TC Total Capacity kW Values mentioned in the table are based on the following conditions Pipe length 5 m Height difference 0 m Outdoor unit Indoor unit 414 6 3 Heating capacity 6 Capacity table...

Page 423: ... 0 3 78 3 69 3 60 3 51 3 42 24 0 18 0 3 78 3 69 3 60 3 51 3 42 Model ARXG12KSLAP Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 3 12 3 05 2 98 2 90 2 83 10 0 11 0 3 63 3 54 3 46 3 37 3 28 5 0 7 0 3 83 3 74 3 65 3 56 3 47 0 0 2 0 4 38 4 28 4 18 4 07 3 97 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 ...

Page 424: ...3 0 7 09 6 92 6 75 6 58 6 41 7 0 6 0 7 09 6 92 6 75 6 58 6 41 10 0 8 0 7 09 6 92 6 75 6 58 6 41 15 0 10 0 7 09 6 92 6 75 6 58 6 41 20 0 15 0 7 09 6 92 6 75 6 58 6 41 24 0 18 0 7 09 6 92 6 75 6 58 6 41 NOTES TC Total Capacity kW Values mentioned in the table are based on the following conditions Pipe length 5 m Height difference 0 m Outdoor unit Indoor unit 416 6 3 Heating capacity 6 Capacity table...

Page 425: ... 0 3 78 3 69 3 60 3 51 3 42 24 0 18 0 3 78 3 69 3 60 3 51 3 42 Model ARXG12KLLAP Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 3 12 3 05 2 98 2 90 2 83 10 0 11 0 3 63 3 54 3 46 3 37 3 28 5 0 7 0 3 83 3 74 3 65 3 56 3 47 0 0 2 0 4 38 4 28 4 18 4 07 3 97 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 ...

Page 426: ...ifference 0 m Outdoor unit Indoor unit Medium static pressure duct type Model ARXG22KMLB Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 5 55 5 41 5 28 5 15 5 02 10 0 11 0 6 44 6 29 6 13 5 98 5 83 5 0 7 0 6 80 6 64 6 48 6 31 6 15 0 0 2 0 7 78 7 60 7 41 7 23 7 04 5 0 3 0 8 95 8 73 8 52 8 31 8 09 7 0 6 0 8 95 8 73 8 52 8 31 8 09 10 0 8 0 8 95 8 73...

Page 427: ...15 0 3 78 3 69 3 60 3 51 3 42 24 0 18 0 3 78 3 69 3 60 3 51 3 42 Model ASYG12KGTB Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 3 12 3 05 2 98 2 90 2 83 10 0 11 0 3 63 3 54 3 46 3 37 3 28 5 0 7 0 3 83 3 74 3 65 3 56 3 47 0 0 2 0 4 38 4 28 4 18 4 07 3 97 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4...

Page 428: ... 98 5 83 5 0 7 0 6 80 6 64 6 48 6 31 6 15 0 0 2 0 7 78 7 60 7 41 7 23 7 04 5 0 3 0 8 95 8 73 8 52 8 31 8 09 7 0 6 0 8 95 8 73 8 52 8 31 8 09 10 0 8 0 8 95 8 73 8 52 8 31 8 09 15 0 10 0 8 95 8 73 8 52 8 31 8 09 20 0 15 0 8 95 8 73 8 52 8 31 8 09 24 0 18 0 8 95 8 73 8 52 8 31 8 09 Model ASYG24KMTB Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 6 ...

Page 429: ...3 69 3 60 3 51 3 42 24 0 18 0 3 78 3 69 3 60 3 51 3 42 Model ASYG12KMTB Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 3 12 3 05 2 98 2 90 2 83 10 0 11 0 3 63 3 54 3 46 3 37 3 28 5 0 7 0 3 83 3 74 3 65 3 56 3 47 0 0 2 0 4 38 4 28 4 18 4 07 3 97 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 68 4 56 1...

Page 430: ...3 69 3 60 3 51 3 42 24 0 18 0 3 78 3 69 3 60 3 51 3 42 Model ASYG12KMCC Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 3 12 3 05 2 98 2 90 2 83 10 0 11 0 3 63 3 54 3 46 3 37 3 28 5 0 7 0 3 83 3 74 3 65 3 56 3 47 0 0 2 0 4 38 4 28 4 18 4 07 3 97 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 68 4 56 1...

Page 431: ...ETA B Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 3 12 3 05 2 98 2 90 2 83 10 0 11 0 3 63 3 54 3 46 3 37 3 28 5 0 7 0 3 83 3 74 3 65 3 56 3 47 0 0 2 0 4 38 4 28 4 18 4 07 3 97 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 68 4 56 15 0 10 0 5 04 4 92 4 80 4 68 4 56 20 0 15 0 5 04 4 92 4 80 4 68 4 ...

Page 432: ...Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 5 55 5 41 5 28 5 15 5 02 10 0 11 0 6 44 6 29 6 13 5 98 5 83 5 0 7 0 6 80 6 64 6 48 6 31 6 15 0 0 2 0 7 78 7 60 7 41 7 23 7 04 5 0 3 0 8 95 8 73 8 52 8 31 8 09 7 0 6 0 8 95 8 73 8 52 8 31 8 09 10 0 8 0 8 95 8 73 8 52 8 31 8 09 15 0 10 0 8 95 8 73 8 52 8 31 8 09 20 0 15 0 8 95 8 73 8 52 8 31 8 09 24 ...

Page 433: ...7 5 0 3 0 5 04 4 92 4 80 4 68 4 56 7 0 6 0 5 04 4 92 4 80 4 68 4 56 10 0 8 0 5 04 4 92 4 80 4 68 4 56 15 0 10 0 5 04 4 92 4 80 4 68 4 56 20 0 15 0 5 04 4 92 4 80 4 68 4 56 24 0 18 0 5 04 4 92 4 80 4 68 4 56 Model AGYG14KVCA Outdoor temperature Indoor temperature CDB 16 0 18 0 20 0 22 0 24 0 CDB CWB TC TC TC TC TC 15 0 16 0 3 65 3 56 3 47 3 39 3 30 10 0 11 0 4 23 4 13 4 03 3 93 3 83 5 0 7 0 4 47 4 ...

Page 434: ...988 0 974 0 960 0 946 0 1 000 1 000 0 992 0 978 0 964 0 950 Indoor unit is lower than outdoor unit 2 2 5 1 000 1 000 0 992 0 978 0 964 0 950 5 1 000 0 992 0 978 0 964 0 950 10 0 992 0 978 0 964 0 950 15 0 978 0 964 0 950 Heating Pipe length m 2 5 5 10 15 20 25 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 976 0 957 0 938 10 0 991 0 976 0 957 0 938 5 1 000 0 991 0 976 0 957 0...

Page 435: ...49 0 930 15 0 962 0 944 0 925 Indoor unit 12 000 Btu h Cooling Pipe length m 2 5 5 10 15 20 25 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 937 0 912 0 888 10 0 970 0 944 0 919 0 896 5 0 992 0 978 0 952 0 927 0 903 2 5 0 996 0 996 0 982 0 956 0 930 0 907 0 1 000 1 000 0 986 0 960 0 934 0 910 Indoor unit is lower than outdoor unit 2 2 5 1 000 1 000 0 986 0 960 0 934 0 910 5 ...

Page 436: ...35 0 910 15 0 957 0 930 0 905 Indoor unit 18 000 Btu h Cooling Pipe length m 2 5 5 10 15 20 25 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 968 0 961 0 954 10 0 982 0 976 0 969 0 962 5 0 992 0 990 0 984 0 977 0 970 2 5 0 996 0 996 0 994 0 988 0 981 0 974 0 1 000 1 000 0 998 0 992 0 985 0 978 Indoor unit is lower than outdoor unit 2 2 5 1 000 1 000 0 998 0 992 0 985 0 978 5 ...

Page 437: ...29 0 904 15 0 949 0 925 0 899 Indoor unit 24 000 Btu h Cooling Pipe length m 2 5 5 10 15 20 25 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 978 0 969 0 953 10 0 986 0 986 0 977 0 961 5 0 992 0 994 0 994 0 984 0 968 2 5 0 996 0 996 0 998 0 998 0 988 0 972 0 1 000 1 000 1 002 1 002 0 992 0 976 Indoor unit is lower than outdoor unit 2 2 5 1 000 1 000 1 002 1 002 0 992 0 976 5 ...

Page 438: ...nt type R32 Refrigerant amount g 2 500 Refrigerant charge Total pipe length m 40 or less 50 60 70 75 Max 20 g m Additional charge amount g 0 200 400 600 700 430 8 1 Model AOYG36KBTA5 8 Additional charge calculation OUTDOOR UNIT AOYG36KBTA5 OUTDOOR UNIT AOYG36KBTA5 ...

Page 439: ...9 Airflow 9 1 Model AOYG36KBTA5 Cooling m3 h 2 450 l s 708 CFM 1 501 Heating m3 h 2 900 l s 833 CFM 1 766 431 9 1 Model AOYG36KBTA5 9 Airflow OUTDOOR UNIT AOYG36KBTA5 OUTDOOR UNIT AOYG36KBTA5 ...

Page 440: ... band sound pressure level dB 0 dB 0 0002 µbar 80 70 60 50 40 30 20 10 0 Octave band center frequency Hz 63 125 250 500 1 000 8 000 2 000 4 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 10 2 Sound level check point 1 m Microphone Microphone Rear Airflow Rear view Side view NOTE Detailed shape of the actual outdoor unit might be slightly different from the one illustrated ab...

Page 441: ... is the total current of the indoor unit and the outdoor unit 2 Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005 As the regulations of wire size and circuit breaker differ in each country or region select appropriate de vices complied to the regional standard 3 This is the wiring length in case voltage descent is less than 2 When the wiring length be comes longer...

Page 442: ...essor protection Temperature thermistor Discharge temp Activate 110 C Compressor stop Reset After 7 minutes Compressor restart Temperature thermistor Compressor bottom temp Activate 108 C Compressor stop Reset After 3 minutes and 80 C or less Compressor restart Thermal protection program Outdoor temp Only in COOL or DRY mode Activate 20 C Compressor stop Reset 15 C Compressor restart 434 12 Safety...

Page 443: ... to performing the local settings Otherwise the compressor may fail Discharge any static electricity from your body before touching the push switches Never touch any terminal or pattern of any parts on the control board The positions of the switches on the outdoor unit control board are shown in the figure below MONITOR POWER ERROR MODE E F GRN RED A B C D CHECK SET 1 TEST RUN PUMP DOWN SET 2 ON O...

Page 444: ...R MODE A GRN RED B C D E F CHECK SET 1 TEST RUN PUMP DOWN SET 2 ON ON 1 2 3 DIP switch part LED display part SW1 SW2 1 Be sure to disconnect the power supply or turn off the breaker 2 Change the DIP switch setting according to the required setting 436 13 1 Setting methods 13 Function settings OUTDOOR UNIT AOYG36KBTA5 OUTDOOR UNIT AOYG36KBTA5 ...

Page 445: ...W1 Push For the test run start and stop For the pump down start and stop SW2 Push For when check run function is activated For displaying the check run For resetting the Automatic wiring correction memory SET1 1 DIP For selecting cooling or heating during test operation OFF SET1 2 DIP For switching SW1 operation OFF SET1 3 DIP Prohibited OFF Do not change SET1 4 DIP For outdoor unit low noise oper...

Page 446: ... from the Central remote controller SET1 4 Setting Factory setting ON Continuous operation OFF Follow the Central remote controller settings SET2 1 Setting Factory setting ON Lower OFF Low 13 3 Changing the current limit function Change the outdoor unit current limit function by using this setting CAUTION When the current limited function is working cooling and heating capacity will decrease When ...

Page 447: ... unit open Gas pipe and liquid pipe 8 Is the power supply connected for more than 12 hours Restrictions applicable when performing the check run When the check run starts all indoor units connected to the outdoor unit will start to run automati cally During the check run you cannot check the operation of the indoor units separately After the check run check the operation of the indoor units separa...

Page 448: ...ff the power and check whether the indoor and outdoor communication lines are properly connected If there is no operation for 1 minute the LED will return to the original display POWER MODE LED ON Example When 4 indoor units A to D are connected MONITOR POWER ERROR MODE GRN RED A B C D E F 2 blink 3 Press the CHECK switch for 3 seconds or more again Check run is initiated When check run is initiat...

Page 449: ... C of the 4 units are reversed After the number of connected units are displayed B and C will light up in reverse MONITOR POWER ERROR MODE GRN RED A B C D E F 7 s 7 s 7 s 7 s 2 blink NOTES Automatic wiring correction will not be completed if the power supply is disconnected while dis playing the results To confirm the automatic wiring correction be sure to carry out step 5 If frost is formed on th...

Page 450: ...WER ERROR MODE GRN RED A B C D E F 2 blink 7 s 7 s 7 s 7 s Example of result table a Write a where the LEDs light up in the order that they light up A B C D E F 1 2 3 4 5 6 7 b Based on the results of step a record as follows Trace the dotted circle with a pen if multiple places light up A B C D E F Write the order from A to D in which the LEDs lit up inside the circle A B C D E F A B C D 442 14 1...

Page 451: ...y press the CHECK switch for 3 seconds or more After LEDs A to F have lit in turn all LEDs will light up indicating that the automatic wiring cor rection is completed 2 blink MONITOR POWER ERROR MODE GRN RED A B C D E F 6 Disconnect the power supply or turn off the breaker and wait 10 minutes then turn the power back on and perform test run NOTE If you do not disconnect the power supply or turn of...

Page 452: ...d You can compare the result that is recorded in step 4 of Chapter 14 1 3 Operating procedure for check run on page 364 If the automatic wiring correction is not completed the POWER MODE LED blinks twice and the MONITOR LED turns off Memory resetting of automatic wiring correction CAUTION When relocating the unit reset the memory beforehand or the unit may not function normally 1 Push the CHECK sw...

Page 453: ...the breaker before changing the DIP switch settings 1 Check the 3 way valves both at the liquid side and gas side are opened Confirm that the DIP switch SET1 2 is switched off 2 Set the operation mode to COOL or HEAT When switching the DIP switch SET1 1 between HEAT and COOL disconnect the power supply or turn off the circuit breaker beforehand SET 1 ON HEAT COOL SET1 1 In the first test run be su...

Page 454: ...ror occurs the error LED blinks at high speed MONITOR POWER ERROR MODE GRN RED A B C D E F blink High speed Error location LEDs A to F of MONITOR light and indicate the location of the error In the case of an overall error LEDs A to F of MONITOR do not light Example Coil error on indoor unit B MONITOR POWER ERROR MODE GRN RED A B C D E F blink High speed 446 14 2 Test run 14 Check and test OUTDOOR...

Page 455: ... MONITOR ERROR POWER MODE GRN RED A E D C B F Blink High speed 9 blink F 1 2 3 4 5 6 7 8 9 A C F J P U E D C For MONITOR A and B Display mode LED on Blink 0 5s Light on Number of blinking A 10 blink C 11 blink F 12 blink J 13 blink P 14 blink U 15 blink 447 14 3 Error code 14 Check and test OUTDOOR UNIT AOYG36KBTA5 OUTDOOR UNIT AOYG36KBTA5 ...

Page 456: ...ddle temp sensor error 73 3 Heat exchanger liquid temp sensor error 74 1 Outdoor temp sensor error 75 1 Suction gas temp sensor error 76 1 Valve sensor error 76 2 77 1 Heat sink temp sensor error 84 1 Current sensor 1 error stoppage permanently 86 1 Discharge pressure sensor error 86 4 High pressure switch 1 error 94 1 Trip detection 95 1 Compressor motor control error stoppage permanently 97 3 Fa...

Page 457: ...eaker is turned off when changing the DIP switch SET1 2 DIP switch SET 1 ON 3 To start operation push the PUMP DOWN switch SW1 for 3 seconds or push the switch after the power has been on for 3 minutes TEST RUN PUMP DOWN Push switch SW1 During pump down the LED POWER MODE blinks 3 times consecutively 3 blink MONITOR POWER ERROR MODE GRN RED A B C D E F NOTE If the PUMP DOWN switch SW1 is pushed wh...

Page 458: ...till continues open the liquid pipe valve Then per form the procedure again starting from step 3 To cancel the pump down operation push the PUMP DOWN switch SW1 again The indi cation of the LED returns to the original state which is before starting the pump down opera tion POWER MODE LED On The pump down may stop before completion due to an error To complete the pump down operation correct the err...

Page 459: ...or Q ty Part name Exterior Q ty Installation manual 1 Adapter K mm in 12 70 1 2 to 9 52 3 8 2 Drain pipe 1 Adapter H mm in 9 52 3 8 to 12 70 1 2 1 Cable tie small 1 451 15 1 Model AOYG36KBTA5 15 Accessories OUTDOOR UNIT AOYG36KBTA5 OUTDOOR UNIT AOYG36KBTA5 ...

Page 460: ...er cable supplied with this controller is for indoor use If the cable for outdoor use is required purchase an appropriate cable locally Material is not specified However it should be selected considering the installing environment temperature humidity and regional regulations RoHS Directive etc The cable from the central remote controller should be connected to connector P400 of the outdoor unit 4...

Page 461: ...measures Reference When installed near adjacent houses Perform installation work so that operating sound does not disturb the neighbors 1 Install a soundproof barrier 2 Change the installation site When there is the possibility of strong wind If the outdoor unit is exposed to strong wind capacity may drop frost may form during heating and operation may be stopped by high pressure rise In addition ...