8 Mode Settings and Functions
8-36
8
897N120152H FDC NX10N Instruction Manual 04.2022
M16 Edit ID
ID OLD=1111111111111
ID NEW=
■
M16 Edit ID
ID OLD=
1111111111111
ID NEW=1234567890123
Accept
Accept=>Print
Accept=>Transmit
Cancel
Password?
■
MODE
RERUN
START
START
START
(Example) ID=1111111111111
ID=1234567890123
Select
Returns to data selection screen
Selecting [Accept]
saves the edited result.
Selecting [Accept
⇒
Transmit]
saves the edited result and
transmits it to the host computer.
Selecting [Accept
⇒
Print]
saves the edited result and
prints it by the external printer.
Selecting [Cancel]
cancels the edit.
(Inputting the administrator password
is not needed for [Cancel].)
Input the administrator password.
(3) Input new numbers for the sample ID.
Input a new sample ID and press the
ENTER
key.
NOTE:
If the
C (clear)
key is pressed when a cursor
is located in the
[NEW]
line having no data in-
put, the analyzer returns to the data selection
screen.
(4) The edited result (the new sample ID) will be dis-
played.
Make sure that the IDs (before editing
[OLD=xxxx]
and after editing
[NEW=xxxx]
) are
correct.
(5) Accept the edited result.
After confirming the edited result, select any of
the following options using the
keys and
press the
ENTER
key.
- To accept: =>
[Accept]
- To accept and print: =>
[Accept => Print]
- To accept and transmit: =>
[Accept => Transmit]
- To cancel: =>
[Cancel]
Next, on the password input screen, input the
administrator password and press the
ENTER
key.
NOTE:
In the event of the password being lost, turn the
power switch off.
NOTE:
If the connection with an external printer or a
host computer is not confirmed,
[Accept =>
Print]
or
[Accept => Transmit]
is not displayed
respectively.
:
After a beep sounds and the message is dis-
played about two seconds, the analyzer returns
to the test result dialog.
If the printer is not connected.
9
0QRTKPVGTEQPPGEVGF
6WTPRQYGT591((
%JGEMVJGEQPPGEVKQP
If the host computer is not connected.
9
0QJQUVEQOEQPPGEVGF
6WTPRQYGT591((
%JGEMVJGEQPPGEVKQP
:
When the test data is edited, the edited data
is recorded as the latest data, and the original
data remains unchanged.
(6) The display returns to the data selection dialog.
Press the
C (Clear)
key to quit the mode.
Summary of Contents for DRI-CHEM NX10N
Page 2: ......
Page 4: ......
Page 8: ...897N120152H FDC NX10N Instruction Manual 04 2022 iv Contents...
Page 18: ...1 Safe Usage and Handling Precautions 1 10 1 897N120152H FDC NX10N Instruction Manual 04 2022...
Page 24: ...3 Principles of Operation 3 2 3 897N120152H FDC NX10N Instruction Manual 04 2022...
Page 46: ...6 Quality Control 6 2 6 897N120152H FDC NX10N Instruction Manual 04 2022...
Page 54: ...7 Troubleshooting 7 8 7 897N120152H FDC NX10N Instruction Manual 04 2022...
Page 92: ...8 Mode Settings and Functions 8 38 8 897N120152H FDC NX10N Instruction Manual 04 2022...
Page 94: ...9 Other Functions 9 2 9 897N120152H FDC NX10N Instruction Manual 04 2022...
Page 98: ...10 Specifications Consumables 10 4 10 897N120152H FDC NX10N Instruction Manual 04 2022...
Page 100: ...11 Glossary 11 2 11 897N120152H FDC NX10N Instruction Manual 04 2022...
Page 101: ......