49
10. Add Disinfectant Tablets to Chlorinator (if applicable).
•
Open the disinfectant package and place tablets in the cylinder prior to system start-up.
11. Check Alarm/Control Panel and Air Pump.
•
Check to be sure that Alarm/Control Panel is located in a secure, accessible location.
•
Check fittings and wire connections; they should be tight and secure. This includes connection
between air hose and pressure switch.
•
Important: Check to be sure that all panel penetrations are airtight and watertight. Be sure no
gas from treatment system can leak into Alarm/Controller.
•
Be sure electrical cord between air pump and outlet is free and clear, and no object is on cord.
(Not applicable to hardwired panels).
•
Check to be sure that panel is closed, secure and toggle switch is set to “Normal” setting.
•
If the air pump does not operate, check the air pump auto-stop switch, power cable
connection and air pump diaphragm.
12. Final Site Preparation.
•
Close and secure all tank access covers.
•
Close and secure air pump protection.
13. Owner Communication
•
Be sure that business owner has a copy of the FujiClean USA Warranty information.
•
Be sure that service provider contact information is affixed to Alarm/Control Panel.
Warranty Activation.
Fill out Warranty Activation Card (received with this Installation Manual) and return
to FujiClean USA to activate system Warranty. Warranty activation is also available via
www.fujicleanusa.com
. Please call FujiClean USA for assistance if necessary: 207-406-2927.