4. Open all access covers and secure the area around the access openings.
5. Water Level is at Low Water Level (LWL).
•
Check that tank has been filled to LWL mark for all three chambers.
6. High Water Float Switch Check.
•
Check that the high water float switch is operating freely. Lift the high water float switch
to check that the alarm is triggered.
(Note: Float should have 3.5” tether. Activation horizon is 1.5” above or below level
horizon).
47
1. Outside Environment Check.
FujiClean Treatment System is accessible and nothing inhibits access to maintenance.
•
Surface water is draining away from risers and access covers.
•
No signs of physical damage to the treatment system, piping, alarms or components.
•
No unusual smells around the system.
•
No unusually loud air pump noise, such as rattling.
2. Air Pump Box Check.
•
Open the air pump box, make sure that it is operating properly.
•
Inspect all fittings and vents to ensure they are clean and dry and that air pump is located so
that it is protected from dust and particles, will remain dry and not be submerged.
3. Air Pump Operation and Air Pump Alarm Check.
•
Make sure the air pump operates properly.
•
Turn off the air pump (unplug or turn off at alarm/control panel breaker switch) for a few
moments to check that the alarm is triggered.
Note: For panels with air pressure switches, it may take a minute or two before air dissipates
enough to trigger alarm.
Start-Up Procedures