27
Step 7: Connect 3/4” or 1” air line
conduit. Please refer to table
below for sizing. Please refer page
17 for air pump location detail.
Step 7 continued: Set and secure risers to tank.
Step 8: Locate and Install Air Pump/Control Panel. Please refer the details page 17-18.
Step 9: Install float switch electrical cord. Connect through a male adaptor (caulked watertight to
prevent septic gas leakage) or watertight fitting. An interior connection to direct burial cable is
also an acceptable option. See details on page 19.
3/4” PVC conduit
Air Line Conduit Diameter Table. (For conduit runs with fewer than 5 elbows)
FujiClean Model/
Air Pump Size
Air Pump to Tank
Distance
CE14
/
FujiMAC 150RII
CE21, CEN14
/
FujiMAC 200RII
CE30, CEN21
/
FujiMAC 150RII (2)
<33 feet
3/4”
3/4”
1”
<100 feet
1”
1”
1”