9 List of commands
Command
Description
<id>AB<para5>
Measuring range analogue output of air pressure (Analogue Barometer).
<id>AD<para5>
Delay of runtime measurement (Acquisition Delay).
<id>AH<para5>
Measuring range analogue output of relative humidity (Analogue
Humidity).
<id>AL<para5>
Measuring range analogue output of brightness (Analogue Luminance).
<id>AM<para5>
Setting of averaging method (Averaging Mode).
<id>AO<para5>
Switch the analogue outputs on/off (Analogue On).
<id>AP<para5>
Measuring range analogue output of precipitation intensity (Analogue
Precipitation).
Command AQ
<id>AQ<para5>
Measuring range analogue output of daily sum of precipitation (Analogue
Qty).
<id>AR<para5>
Scale the analogue wind speed output (Analogue Range).
<id>AS<para5>
Set the analogue outputs to preselected values (Analogue Static).
<id>AT<para5>
Measuring range analogue output of temperature (Analogue
Temperature).
<id>AV<para5>
Averaging period (Average).
<id>BO<para5>
Selection calculation mode for total brightness (Brightness Option).
<id>BP<para5>
Select parity for the interfaces (Baud Parity).
<id>BR<para5>
Select baud rate for the interfaces (Baud Rate).
<id>BT<para5>
Activating termination of RS485
– bus (Bus Termination).
<id>CI<para5>
Select command interpreter (Command Interpreter).
<id>CS<para5>
Saving configuration (Configuration Save).
<id>DM<para5>
Duplex mode (Duplex Mode).
<id>DO<para5>
Selecting measured or calculated brightness direction as analogue value.
<id>DT<para5>
Date and time stamp (Date and Timestamp).
<id>EI<para5>
Analogue values in case of error (Error Inversion).
Command ET
<id>ET<para5>
Time until a measuring value error sets the generic error bit (Error
Timeout).
<id>GP<para5>
Query the GPS data and the position of the sun.
<id>HC<para5>
Defines the lower threshold for heating operation (Heating Condition).
<id>HH<para5>
Output Help (Help, identical to: <id>??<para5>).
<id>HP<para5>
Lowest heating level in % (Heating Power).
<id>HS<para5>
Selecting mode for setting the station height (Height Setting).
<id>HT<para5>
Heating control ON/OFF/automatic (Heating).
<id>ID<para5>
WEATHER STATION ID (IDentifier).
<id>KY<para5>
Access key (Key).
<id>MC<para5>
Magnetic compass correction optional.
<id>MD>>para5> Measuring interval for the wind measurement (Measurement Delay).
<id>NC<para5>
Correction to north (North Correction).
<id>OL<para5>
Linking analogue measuring values with the outputs (Output Link).
<id>OP<para5>
For extending the output telegrams by optional parameters.
<id>OR<para5>
Telegram output interval (Output Rate).
<id>OS<para5>
Scale wind speed output (Output Scale).
<id>PE<para5>
Precipitation events lower precipitation threshold (Precipitation Events).
<id>PH<para5>
Precipitation threshold single volume (Precipitation High).
<id>PN<para5>
Precipitation events upper precipitation threshold (Precipitation Number).