45 SERIES GAS FRYERS
CHAPTER 3: OPERATING INSTRUCTIONS
3-9
?
SOLID STATE
Trouble
Light
Temperature
Knob
Melt Cycle
Switch
C
F
Power
Switch
Power
On
Light
Melt
Cycle
Light
Heat
Mode
Light
Frymaster
ANALOG CONTROLLER
ANALOG CONTROLLER
In units equipped with analog controllers, the
frypot thermostat has been replaced with a
solid-state temperature probe and solid-state
electronics mounted on the control panel, re-
ducing the number of moving parts and elimi-
nating the need to calibrate the thermostat.
The temperature probe is connected to the
control circuitry via an interface board behind
the control panel.
The cooking temperature setpoint is set by ro-
tating the Temperature Knob to the desired
temperature.
When the Power switch is placed in the ON
position, electrical current is supplied to the
fryer’s components and the Power On Light
illuminates.
Placing the Melt Cycle switch in the ON
position causes the burner to cycle on for a
few seconds and off for a longer period until
the temperature in the frypot reaches 180ºF
(82ºC). At that time the unit automatically
enters the heat mode, causing the burner to
remain lit until the setpoint is reached. When
in the melt cycle, the Melt Cycle Light
will
alternately illuminate and go out as the burner
cycles on and off. When the unit enters the
heat mode, the Heat Mode Light
will
illuminate and remain on until the setpoint is
reached. The Trouble Light indicates probe
circuit or high limit circuit problems.