Every 6 months
CAUTION!
Danger due to the effect of compressed air.
This can result in damage to property.
▶
Do not bring the air nozzle too close to electronic components.
1
Dismantle device side panels and clean inside of device with dry, reduced
compressed air
2
If a lot of dust has accumulated, clean the cooling air ducts
WARNING!
An electric shock can be fatal!
Risk of electric shock from improperly connected ground cables and equipment
grounds.
▶
When reassembling the side panels, make sure that grounding cables and
equipment grounds are properly connected.
Disposal
Dispose of in accordance with the applicable national and local regulations.