Shielding gas setup menu
General
The Protective gas shield set-up menu provides easy access to the protective gas
shield settings.
Opening the Pro-
tective gas
shield set-up
menu
1
Press and hold the "Mode" button
2
Press the Gas test button
The power source is now in the Protective gas shield set-up menu.
The last welding parameter selected is displayed.
Changing weld-
ing parameters
1
Use the left or right parameter selection button to select the
welding parameter that you want to change
2
Use the adjusting dial to change the welding parameter value
Exiting the set-
up menu
1
Press the Mode button
Welding para-
meters in the
Protective gas
shield set-up
menu
GPr
Gas pre-flow time
Unit
s
Setting range
0,0 - 9,9
Factory setting
0,4
G-L
Gas-Low - gas post-flow time at minimum welding current
(minimum gas post-flow time)
Unit
s
Setting range
0,0 - 25,0
Factory setting
5
G-H
Gas-High - Increase in the gas post-flow time at maximum welding current
Unit
s
Setting range
0.0 - 40.0/Aut
Factory setting
Aut
76
Summary of Contents for TransTig 1700
Page 2: ......
Page 19: ...General information 19...
Page 20: ...20...
Page 25: ...Control elements and connections 25...
Page 26: ...26...
Page 45: ...Installation and commissioning 45...
Page 46: ...46...
Page 55: ...Welding 55...
Page 56: ...56...
Page 72: ...72...
Page 73: ...Setup settings 73...
Page 74: ...74...
Page 87: ...Troubleshooting and maintenance 87...
Page 88: ...88...
Page 96: ...96...
Page 97: ...Appendix 97...
Page 98: ...98...
Page 124: ......