![Fronius TransTig 1700 Operating Instructions Manual Download Page 63](http://html1.mh-extra.com/html/fronius/transtig-1700/transtig-1700_operating-instructions-manual_2339442063.webp)
2
Only with MagicWave: Press the Mode button to select the required TIG
mode:
AC welding process
AC welding process with automatic cap-shaping function
DC welding process
3
Use the left or right parameter selection button to select the relevant weld-
ing parameters in the welding parameters overview
4
Use the adjusting dial to set the selected welding parameter to the required
value
All welding parameter set values that have been set using the adjusting dial
remain stored until the next time they are changed. This applies even if the
power source is switched off and on again in the meantime.
5
Open the gas cylinder valve
6
Set the shielding gas flow rate:
Press the Gas test button
The test gas flow lasts for a maximum of 30 seconds. Press the button again
to stop the gas flow prematurely.
-
Turn the adjusting screw on the underside of the pressure regulator until
the pressure gauge shows the required gas flow rate
7
For long hosepacks and if condensation forms when the device is left unused
in a cold environment:
purge protective gas shield and set the GPU set-up parameter to a time value
8
Start welding (ignite the arc)
63
EN
Summary of Contents for TransTig 1700
Page 2: ......
Page 19: ...General information 19...
Page 20: ...20...
Page 25: ...Control elements and connections 25...
Page 26: ...26...
Page 45: ...Installation and commissioning 45...
Page 46: ...46...
Page 55: ...Welding 55...
Page 56: ...56...
Page 72: ...72...
Page 73: ...Setup settings 73...
Page 74: ...74...
Page 87: ...Troubleshooting and maintenance 87...
Page 88: ...88...
Page 96: ...96...
Page 97: ...Appendix 97...
Page 98: ...98...
Page 124: ......