Welding current at
10 min/25 °C (77 °F) 50% D.C.
2)
-
10 min/25 °C (77 °F) 60% D.C.
2)
-
10 min/25 °C (77 °F) 100% D.C.
2)
80 A
10 min/40 °C (104 °F) 40% D.C.
2)
-
10 min/40 °C (104 °F) 60% D.C.
2)
80 A
10 min/40 °C (104 °F) 100% D.C.
2)
70 A
Open circuit voltage
85 V
Working voltage
TIG
10.0 - 13.2 V
Electrode
10.4 - 23.2 V
Striking voltage (U
p
)
9.0 kV
The arc striking voltage is suitable for manual operation.
Degree of protection
IP 23
Type of cooling
AF
Insulation class
B
EMC device class
(in accordance with EN/IEC 60974-10)
A
Dimensions L/W/H (with handle)
485 / 180 / 344 m
m
19.1 / 7.1 / 13.5 in.
Weight (without handle)
14.2 kg
31.3 lb.
Weight (with handle)
-
-
Mark of conformity
S, CE
Idle state power consumption at 230 V
23.1 W
Power source efficiency at 80 A / 23.2 V
81%
TransTig 2200
Mains voltage
230 V
Mains voltage tolerance
-20% / +15%
Grid frequency
50/60 Hz
Mains fuse protection (slow-blow)
16 A
Mains connection
1)
No restrictions
Primary continuous power (100% D.C.
2)
)
3.0 kVA
Cos phi
0.99
Welding current range
TIG
3 - 220 A
Electrode
10 - 180 A
111
EN
Summary of Contents for TransTig 1700
Page 2: ......
Page 19: ...General information 19...
Page 20: ...20...
Page 25: ...Control elements and connections 25...
Page 26: ...26...
Page 45: ...Installation and commissioning 45...
Page 46: ...46...
Page 55: ...Welding 55...
Page 56: ...56...
Page 72: ...72...
Page 73: ...Setup settings 73...
Page 74: ...74...
Page 87: ...Troubleshooting and maintenance 87...
Page 88: ...88...
Page 96: ...96...
Page 97: ...Appendix 97...
Page 98: ...98...
Page 124: ......