If necessary, provide adequate earthing for the workpiece.
Switch off unused devices.
Wear a safety harness if working at height.
Before working on the device, switch it off and pull out the mains plug.
Attach a clearly legible and easy-to-understand warning sign to the device to
prevent anyone from plugging the mains plug back in and switching it on again.
After opening the device:
-
Discharge all live components
-
Ensure that all components in the device are de-energised.
If work on live parts is required, appoint a second person to switch off the main
switch at the right moment.
Meandering
welding currents
If the following instructions are ignored, meandering welding currents can devel-
op with the following consequences:
-
Fire hazard
-
Overheating of parts connected to the workpiece
-
Damage to ground conductors
-
Damage to device and other electrical equipment
Ensure that the workpiece is held securely by the workpiece clamp.
Attach the workpiece clamp as close as possible to the area that is to be welded.
Position the device with sufficient insulation against electrically conductive envir-
onments, such as insulation against conductive floor or insulation to conductive
racks.
If power distribution boards, twin-head mounts, etc., are being used, note the fol-
lowing: The electrode of the welding torch / electrode holder that is not used is
also live. Make sure that the welding torch / electrode holder that is not used is
kept sufficiently insulated.
In the case of automated MIG/MAG applications, ensure that only an insulated
wire electrode is routed from the welding wire drum, large wirefeeder spool or
wirespool to the wirefeeder.
EMC Device
Classifications
Devices in emission class A:
-
Are only designed for use in industrial settings
-
Can cause line-bound and radiated interference in other areas
Devices in emission class B:
-
Satisfy the emissions criteria for residential and industrial areas. This is also
true for residential areas in which the energy is supplied from the public low-
voltage mains.
EMC device classification as per the rating plate or technical data.
EMC measures
In certain cases, even though a device complies with the standard limit values for
emissions, it may affect the application area for which it was designed (e.g. when
there is sensitive equipment at the same location, or if the site where the device
is installed is close to either radio or television receivers).
12
Summary of Contents for TransTig 1700
Page 2: ......
Page 19: ...General information 19...
Page 20: ...20...
Page 25: ...Control elements and connections 25...
Page 26: ...26...
Page 45: ...Installation and commissioning 45...
Page 46: ...46...
Page 55: ...Welding 55...
Page 56: ...56...
Page 72: ...72...
Page 73: ...Setup settings 73...
Page 74: ...74...
Page 87: ...Troubleshooting and maintenance 87...
Page 88: ...88...
Page 96: ...96...
Page 97: ...Appendix 97...
Page 98: ...98...
Page 124: ......