The value set for G-H only applies if the maximum welding current actually has
been set. The actual value is derived from the present welding current. For a
medium welding current, for example, the actual value will be half of the value
set for G-H.
IMPORTANT!
The values set for the G-L and G-H set-up parameters are added
together. For example, if both welding parameters are set to the maximum (40
s), the gas post-flow will last:
-
40 s at minimum welding current
-
80 s at maximum welding current
-
60 s if the welding current is exactly half the maximum, etc.
If Aut is set, the gas post-flow time G-H is calculated automatically.
I
min
I
max
I
t
G-H
G-L
(1)
(2)
Legend:
(1).... Gas post-flow time at any given
moment
(2).... Welding current at any given
moment
Gas post-flow time as a function of the welding current
GPU
Gas purger - protective gas shield purging
Unit
min
Setting range
OFF / 0.1 - 10.0
Factory setting
OFF
Purging of the protective gas shield begins as soon as GPU is allocated a value.
For safety reasons, purging of the protective gas shield cannot be restarted un-
til a new GPU value is entered.
IMPORTANT!
Purging of the protective gas shield is necessary if condensation
forms when the device is left unused in a cold environment for a prolonged
period. Long hosepacks are most affected.
77
EN
Summary of Contents for TransTig 1700
Page 2: ......
Page 19: ...General information 19...
Page 20: ...20...
Page 25: ...Control elements and connections 25...
Page 26: ...26...
Page 45: ...Installation and commissioning 45...
Page 46: ...46...
Page 55: ...Welding 55...
Page 56: ...56...
Page 72: ...72...
Page 73: ...Setup settings 73...
Page 74: ...74...
Page 87: ...Troubleshooting and maintenance 87...
Page 88: ...88...
Page 96: ...96...
Page 97: ...Appendix 97...
Page 98: ...98...
Page 124: ......