TransTig 3000
MV
Mains voltage
3 x 200 - 240 V
3 x 400 - 460 V
1 x 200 - 240 V
Mains voltage tolerance
± 10%
Grid frequency
50/60 Hz
Mains fuse protection (slow-blow)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
16 A
32 A
32 A
Mains connection
1)
Z
max
on PCC
3)
= 97 mOhm
Primary continuous power (100% D.C.
2)
)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
5.9 kVA
5.0 kVA
4.3 kVA
Cos phi
0.99
Welding current range (3-phase)
TIG
3 - 300 A
Electrode
10 - 300 A
Welding current range (single phase)
TIG
3 - 220 A
Electrode
10 - 180 A
Welding current at 3 x 400 - 460 V
10 min/40 °C (104 °F) 45% D.C.
2)
300 A
10 min/40 °C (104 °F) 50% D.C.
2)
-
10 min/40 °C (104 °F) 100% D.C.
2)
240 A
Welding current at 3 x 200 - 240 V
10 min/40 °C (104 °F) 35% D.C.
2)
-
10 min/40 °C (104 °F) 40% D.C.
2)
300 A
10 min/40 °C (104 °F) 100% D.C.
2)
210 A
Welding current at 1 x 200 - 240 V
10 min/40 °C (104 °F) 50% D.C.
2)
-
10 min/40 °C (104 °F) 55% D.C.
2)
220 A
10 min/40 °C (104 °F) 100% D.C.
2)
190 A
Open circuit voltage
85 V
Working voltage
TIG
10.1 - 22.0 V
Electrode
20.4 - 32.0 V
Striking voltage (U
p
)
10 kV
The arc striking voltage is suitable for manual operation.
116
Summary of Contents for TransTig 1700
Page 2: ......
Page 19: ...General information 19...
Page 20: ...20...
Page 25: ...Control elements and connections 25...
Page 26: ...26...
Page 45: ...Installation and commissioning 45...
Page 46: ...46...
Page 55: ...Welding 55...
Page 56: ...56...
Page 72: ...72...
Page 73: ...Setup settings 73...
Page 74: ...74...
Page 87: ...Troubleshooting and maintenance 87...
Page 88: ...88...
Page 96: ...96...
Page 97: ...Appendix 97...
Page 98: ...98...
Page 124: ......