3
Guide the data cables first through the
strain-relief device cap nut and then
through the housing opening.
4
Insert the sealing ring between the cap nut
and the housing opening. Press the data
cables into the seal's cable guide. Then
press in the seal until it reaches the under-
side of the strain-relief device.
5
Fasten the cap nut of the strain-relief
device with a torque of min. 2.5 - max.
4 Nm.
74