Button
-
The function of the "OK/STOP" button can be simulated by means of an ex-
ternal button.
Normal
-
Start ON
Charging starts when an external switch is closed and a battery is detected
or when the charging plug is plugged in by closing the auxiliary contacts and
a battery is detected.
-
Start OFF
Charging starts when a battery is connected.
-
Stop ON
Charging is interrupted when an external switch is opened
or when the charging plug is disconnected by opening the auxiliary contacts.
-
Stop OFF
The opening of an external switch or the auxiliary contacts is ignored.
Contact detection
-
ON
If Start Normal is ON, a battery is connected and the external start/stop
contact is not closed, error 16 is set.
If Stop Normal is ON, charging has been started, the external start/stop con-
tact is opened and the battery is not fully charged, error 16 is set.
-
OFF
Contact detection is not executed.
Refill indicator
The refill indicator is activated as soon as it is necessary to add distilled water to
the battery. The time of the refill request can be defined as follows:
Every x-th week and weekday
-
e.g. refill water every 2nd week on Friday
When "OFF" is set, the refill request does not have to be confirmed.
Option Section
Option Section 1
-
Setting options:
CAN1 (option box)
Cool Bat Guide Easy (Fronius variant only)
Option Section 2 (3 kW only)
-
Setting options:
CAN2 (option box)
Air-Puls (EUW)
Status outputs (3 kW only)
-
External lamp setting (normal or RGB)
48