Adjusting the lifting device
Adjusting the
lifting device
To make it easier to adjust the lifting device, it is advisable to fit one of the fol-
lowing adjustment aids to the torch body:
-
Robacta Twin 500 adjustment aid, item no. 42,0001,5559
-
Robacta Twin 900 adjustment aid, item no. 42,0001,5560
An adjustment aid is not necessary when the gas nozzle is open, as the welding
torch is clamped above the gas nozzle. The gas nozzle can be removed before-
hand. The bracket must be back in the starting position. When the gas nozzle is
mounted, the bracket must be closed.
NOTE!
Ensure that the coolant lines on the gas nozzle cannot be damaged by the ex-
tending/retracting gas nozzle clamping device.
1
Ensure that the lifting device is in its lowest lift position
2
Move the welding torch to the
cleaning position
1
2
1
3