Troubleshooting
Errors in pro-
gram sequence
The parting agent does not spray
Parting agent container is full
Not enough spray
Adjust spray time
Parting agent hose suction filter in the parting agent container is
soiled
Clean the suction filter of the parting agent hose with compressed air
(for more detailed information, see section
from page
No signal from robot
Check robot program
Parting-agent injection nozzle blocked
Clean parting-agent injection nozzle
Contact After-Sales Service (arrange for parting-agent injection
nozzle to be replaced)
Vacuum pump faulty
Contact After-Sales Service (arrange for vacuum pump to be re-
placed)
Mechanical fault on solenoid valve
Contact After-Sales Service (arrange for solenoid valve to be re-
placed)
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Welding torch is poorly cleaned or damaged
Lifting device not adjusted properly
Adjust the lifting device
Cleaning cutter not suited to welding torch shape
Fit the correct cleaning cutter
Cleaning cutter is worn
Replace cleaning cutter
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
81
EN
Summary of Contents for Robacta Reamer V Twin
Page 2: ......
Page 12: ...12...
Page 13: ...General 13...
Page 14: ...14...
Page 18: ...Wear eye protection Notice warning of automatic start up of the device 18...
Page 20: ...20...
Page 21: ...Controls connections and mechan ical components 21...
Page 22: ...22...
Page 27: ...Installation and commissioning 27...
Page 28: ...28...
Page 67: ...Care maintenance and disposal 67...
Page 68: ...68...
Page 72: ...Disposal Dispose of in accordance with the applicable national and local regulations 72...
Page 76: ...76...
Page 77: ...Troubleshooting 77...
Page 78: ...78...
Page 83: ...Technical data 83...
Page 84: ...84...
Page 86: ...86...
Page 87: ...Appendix 87...
Page 88: ...88...
Page 92: ......