72
No shielding gas
All other functions are OK
Cause:
The gas cylinder is empty
Remedy:
Change the gas cylinder
Cause:
The gas pressure regulator is faulty
Remedy:
Change the gas pressure regulator
Cause:
The gas hose is not mounted, or is damaged
Remedy:
Mount / change the gas hose
Cause:
The welding torch is defective
Remedy:
Change the welding torch
Cause:
The gas solenoid valve is defective
Remedy:
Change the gas solenoid valve
Poor welding properties
Cause:
Incorrect welding parameters
Remedy:
Check the settings
Cause:
Incorrect earth (ground) connection
Remedy:
Check the earth (ground) connection and the clamp for correct polarity
The welding torch becomes very hot
Cause:
The design dimensions of the torch are not sufficient for this task
Remedy:
Respect the duty cycle and loading limits
Cause:
Only on water-cooled machines: Water through-flow is insufficient
Remedy:
Check the coolant level, through-flow rate, cleanliness of coolant etc. If
the coolant pump is blocked: Use a screwdriver - placed on the bushing -
to turn the shaft of the coolant pump.
TT2200 /
MW1700/2200
power source
(continued)