The digital power sources are equipped with an intelligent safety system. This means
that apart from the fuse for the coolant-pump, it has been possible to dispense with
melting-type fuses entirely. After a possible malfunction or error has been remedied, the
power source can be put back into normal operation again without any melting-type
fuses having to be changed.
Warning!
An electric shock can be fatal. Before opening up the power source,
switch it off, unplug it from the mains and put up a clearly legible and easy-to-
understand warning sign to stop anybody inadvertently switching the machine
back on again. If necessary, discharge the electrolytic capacitors.
Troubleshooting
If any error message that is not described here appears on the displays, then the fault is
one that can only be put right by a service technician. Make a note of the error message
shown in the display, and of the serial number and configuration of the power source,
and get in touch with our after-sales service, giving them a detailed description of the
error.
no | Prg
Cause:
No pre-programmed program has been selected
Remedy:
Select a pre-programmed program
tP1 | xxx, tP2 | xxx, tP3 | xxx, tP4 | xxx, tP5 | xxx, tP6 | xxx
Cause:
Over-temperature in the primary circuit of the power source
Remedy:
Allow the power source to cool down
tS1 | xxx, tS2 | xxx, tS3 | xxx
Cause:
Over-temperature in the secondary circuit of the power source
Remedy:
Allow the power source to cool down
tSt | xxx
Cause:
Over-temperature in the control circuit
Remedy:
Allow the power source to cool down
Err | 051
Cause:
Mains undervoltage: The mains voltage has dropped below the tolerance
range (-30% / +15%)
Remedy:
Check the mains voltage
Err | 052
Cause:
Mains overvoltage: The mains voltage has risen above the tolerance range
(-30% / +15%)
Remedy:
Check the mains voltage
no | IGn
Cause:
“Ignition time-out” function is active: No current started flowing before the
end of the time specified in the set-up menu. The safety cut-out of the
power source has been triggered.
Remedy:
Press the torch trigger repeatedly; clean the surface of the workpiece; if
necessary, increase the time-period specified in “Set-up menu: Level 2”
before the safety cut-out is triggered.
General remarks
Displayed
service codes
Summary of Contents for MagicWave 1700
Page 2: ......
Page 4: ......
Page 16: ...XII ud_fr_st_sv_00466 022002...
Page 96: ......
Page 108: ...XII ud_fr_st_sv_00467 052002...
Page 188: ......
Page 200: ...XII ud_fr_st_sv_00468 042002...
Page 283: ...TransTIG 2200...
Page 284: ...MagicWave 1700...
Page 285: ...MagicWave 2200...
Page 286: ...FK 2200...