29
Spot welding
For information on setting the “Spot-welding time” set-up parameter (SPt), see the
section headed “The Set-up menu: Level 1”.
If a value has been set for the “SPt” set-up parameter, the operating mode “2-step
mode” (2) will have the function of the spot-welding mode.
Spot-welding status indicator: Remains lit up as long as a value has been
specified for the spot-welding time.
-
Select 2-step mode (2)
-
In the “Set-up menu: Level 1”, set the “SPt” set-up parameter to the desired spot-
welding time.
-
Welding: Briefly pull back the torch trigger
To abort this procedure, pull back the torch trigger once again.
I
Fig.12 Spot welding
t
I
1
GPr
t
up
t
down
SPt
G-L
G-H