60
-
Press the “Mode” button (1) to select either 2-step mode (2) or 4-step mode (3)
(1)
(2)
(3)
-
While pressing and holding the Store button (13), press the “Mode” button (1)
-
The first set-up parameter is displayed (e.g. “SPt”)
Important!
The first parameter to be displayed is always the one that was the last to be
selected the last time the set-up menu was accessed.
-
Select the set-up parameter “2nd” with the parameter selection buttons (8) and (9).
Level 2: TIG set-up parameters
Select
“Parameter 2nd”
Once the set-up parameter “2nd” has been selected:
-
While pressing and holding the Store button (13), press the “Mode” button (1)
-
The first set-up parameter of Level 2 is displayed (e.g. “SFS”)
Important!
The first parameter to be displayed is always the one that was the last to be
selected the last time the set-up menu was accessed.
Accessing
Selecting and
altering the set-
up parameter
-
Select the desired set-up parameter with the parameter selection buttons (8) and
(9).
-
Alter the value of the set-up parameter with the adjusting dial (7)
Exiting and
saving
-
Press the Store button (13) twice
Available set-up
parameters
SFS
....
S
pecial
f
our-
s
tep ... OFF / 1 (Variant 1)
Factory setting: OFF
Variant 1 of the special 4-step operating is described in the section headed: “TIG
operating modes”.
C-C
.....
C
ooling unit
c
ontrol ... (optional) ... AUT / ON / OFF
Factory setting: AUT
In the “AUT” position, the coolant return-flow temperature is checked after a 2-minute
weld off-time. If the return-flow temperature is less than 50 °C, the cooling unit is
switched off automatically.
“AUT” position ...... Cooling unit is switched off 2 minutes after the end of welding
“ON” position ........ Cooling unit is ON all the time
“OFF” position ...... Cooling unit is OFF all the time
Summary of Contents for MagicWave 1700
Page 2: ......
Page 4: ......
Page 16: ...XII ud_fr_st_sv_00466 022002...
Page 96: ......
Page 108: ...XII ud_fr_st_sv_00467 052002...
Page 188: ......
Page 200: ...XII ud_fr_st_sv_00468 042002...
Page 283: ...TransTIG 2200...
Page 284: ...MagicWave 1700...
Page 285: ...MagicWave 2200...
Page 286: ...FK 2200...