67
General remarks
Indicating the welding circuit inductivity L
The way that the hosepack is arranged has a very significant effect on the welding
properties. Particularly with pulsed-arc welding and AC welding, a high welding circuit
inductivity may occur, depending on the length of the hosepack and on the way that it is
arranged. The result is that the current-rise is restricted.
Measuring the
welding circuit
inductivity L
-
Measure the welding circuit resistance “r” (see the section headed: “Indicating the
welding circuit resistance “r”)
-
Select set-up parameter “L”
-
See: “The set-up menu: Level 2”, either sub-section “TIG set-up parameters” or
sub-section “Rod electrode set-up parameters”, depending on which process is
being used
-
The right-hand display now shows the welding circuit inductivity L (e.g. 5
microhenrys)
You can attempt to optimise the welding
result by changing the arrangement of the
hosepack. The hosepack must be laid out
as shown in the illustration.
Fig.29
Correct arrangement of the hosepack