Press the Move to reference point key
(1)
Reference point LED (2) lights up and
indicates that the spot welding gun is
ready
Sheet thickness
correction
Rotate the sheet thickness corrector to adjust the position of the gun arm so that when
closed the drive is located within the operating range (1). The closed position depends on
the thickness of the sheets being welded.
Detail showing welding gun drive in the X-gun opera-
ting range
(1)
Operating range: 10 - 15° from top
dead centre
(2)
0 - 10° = top dead centre
(3)
Sheet thickness correction
Adjusting sheet
thickness correc-
tion
Start the "Sheet thickness compensation" function in Fronius Xplorer (worksheet:
"Overview" - option menu "Calibration - sheet thickness compensation")
(1)
(2)
1
2
(1)
(2)
(3)
-15°-10°
IMPORTANT!
If the operating point in the
closed position is outside the defined oper-
ating range, the specified gun force cannot
be applied.
1
Summary of Contents for DeltaSpot
Page 2: ...0...
Page 4: ...2...
Page 16: ...14...
Page 17: ...General information...
Page 18: ......
Page 22: ...20...
Page 23: ...Control elements and connections...
Page 24: ......
Page 36: ...34...
Page 37: ...Start up...
Page 38: ......
Page 47: ...45 EN 1 6 1 2 3 7 1 1 8 1 9 1 2 10 1 11 11...
Page 54: ...52...
Page 55: ...Spot welding...
Page 56: ......
Page 60: ...58...
Page 61: ...Troubleshooting and maintenance...
Page 62: ......
Page 71: ...69 EN 3 11 Nm 3 4 4 5 5 5 6 24 Nm 6...
Page 74: ...72 Disposal Dispose of in accordance with the applicable national and local regulations...
Page 77: ...Appendix...