8
Danger from fly-
ing sparks
Risks from mains
current and weld-
ing current
If there is any doubt about whether the extraction system is powerful enough,
then the measured toxic emission values should be compared with the permis-
sible limit values.
The following components are responsible, amongst other things, for the de-
gree of toxicity of welding fumes:
-
Metals used for the workpiece
-
Coating of the process tapes
-
Coatings of the materials
-
Cleaners, degreasers, etc.
The relevant material safety data sheets and manufacturer's specifications for
the listed components should therefore be studied carefully.
Flammable fumes (e.g. solvent fumes) should be kept away from the direct
welding process.
Flying sparks may cause fires or explosions.
Never weld close to flammable materials.
Flammable materials must be at least 11 metres (35 ft) away from the welding
process, or alternatively covered with a checked cover.
A suitable, tested fire extinguisher must be available and ready for use.
Sparks and pieces of hot metal may also get into adjacent areas through small
gaps or openings. Take appropriate precautions to prevent any danger of in-
jury or fire.
Welding must not be performed in areas that are subject to fire or explosion or
near sealed tanks, vessels or pipes unless these have been prepared in ac-
cordance with the relevant national and international standards.
Do not carry out welding on containers that are being or have been used to
store gases, propellants, mineral oils or similar products. Residues pose an
explosive hazard.
An electric shock is potentially life threatening and can be fatal.
Do not touch live parts either inside or outside the device.
Make sure that you and others are protected with an adequately insulated, dry
temporary backing or cover for the earth or ground potential. This temporary
backing or cover must extend over the entire area between the body and the
earth or ground potential.
All cables and leads must be secured, undamaged, insulated and adequately
dimensioned. Loose connections, scorched, damaged or inadequately dimen-
sioned cables and leads must be repaired/replaced immediately.
Summary of Contents for DeltaSpot
Page 2: ...0...
Page 4: ...2...
Page 16: ...14...
Page 17: ...General information...
Page 18: ......
Page 22: ...20...
Page 23: ...Control elements and connections...
Page 24: ......
Page 36: ...34...
Page 37: ...Start up...
Page 38: ......
Page 47: ...45 EN 1 6 1 2 3 7 1 1 8 1 9 1 2 10 1 11 11...
Page 54: ...52...
Page 55: ...Spot welding...
Page 56: ......
Page 60: ...58...
Page 61: ...Troubleshooting and maintenance...
Page 62: ......
Page 71: ...69 EN 3 11 Nm 3 4 4 5 5 5 6 24 Nm 6...
Page 74: ...72 Disposal Dispose of in accordance with the applicable national and local regulations...
Page 77: ...Appendix...