CU 800i /460 V
Mains voltage
460 V AC
Mains voltage tolerance
-10% / +10%
Grid frequency
50/60 Hz
Current consumption
0.35 A
Cooling capacity at
Q=1 l/min. + 25 °C (77 °F)
Q = 1 l/min. + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
800 W
500 W
1160 W
730 W
Max. delivery head
45 m
(147 ft. 7.65 in.)
Max. delivery rate
2 l/min
(0.53 gal./min [US])
Max. pump pressure
5 bar
(72.52 psi)
Pump
Vane pump
Pump service life
approx. 10,000 hrs
Coolant capacity
4.5 l
(1.19 gal. [US])
Degree of protection
IP 23
Dimensions l/w/h
706/260/219 mm
(27.8/10.24/8.62 in.)
Weight (without coolant)
13.9 kg
(30.64 Ib.)
Flow monitoring*
(sensor)
Warning at 1 - 0.7 l/min
(0.26 - 0.18 gal./min [US])
Error message below 0.7 l/min
(0.18 gal./min [US])
Coolant temperature monitoring*
Warning above 68 °C (154.4 °F)
Error message above 70 °C (158 °F)
Mark of conformity
CE, CSA
* Optional