CU 1100i /460 V
Mains voltage
460 V AC
Mains voltage tolerance
-10% / +10%
Grid frequency
50/60 Hz
Current consumption
0.35 A
Cooling power at
Q = 1 l/min + 25 °C (77 °F)
Q = 1 l/min + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
1100 W
800 W
1500 W
1100 W
Max. delivery head
45 m
147 ft. 7.65 in.
Max. delivery rate
2 l/min
0.53 gal./min [US]
Max. pump pressure
5 bar
72.52 psi
Pump
Vane pump
Pump service life
approx. 10,000 hrs
Coolant capacity
6 l
1.59 gal. [US]
Degree of protection
IP 23
Dimensions l/w/h
710/300/230 mm
27.95/11.81/9.06 in.
Weight (without coolant)
16.3 kg
35.94 lb.
Flow monitoring
(sensor)
Warning between 1 and 0.7 l/min (0.26 -
0.18 gal./min [US]),
error message below 0.7 l/min (0.18
gal./min [US])
Coolant temperature monitoring
Warning above 68 °C (154.4 °F),
error message above 70 °C (158 °F)
Level sensor*
(functionality depends on the options in-
stalled in the device)
Warning or error message
Mark of conformity
CE, CSA
* Optional
77
EN
Summary of Contents for CU 1100i
Page 2: ......
Page 16: ...16...
Page 17: ...General information 17...
Page 18: ...18...
Page 26: ...26...
Page 27: ...Connections and mechanical com ponents 27...
Page 28: ...28...
Page 31: ...Installation and commissioning 31...
Page 32: ...32...
Page 45: ...Close the cover on the cooling unit connection 3 45 EN...
Page 46: ...46...
Page 47: ...Troubleshooting 47...
Page 48: ...48...
Page 53: ...Care maintenance and disposal 53...
Page 54: ...54...
Page 70: ...70...
Page 71: ...Technical data 71...
Page 72: ...72...
Page 82: ...82...
Page 83: ...83 EN...