CU 1400i Pro /MC
If a TPS 320i C power source is used with a CU 1400i Pro /MC cooling unit, the
cooling unit will not benefit from the maximum pump power.
CU 1400i Pro /MC
Supply voltage
24 V DC
Current consumption
4.4 A
Cooling capacity at
Q=1 l/min. + 25 °C (77 °F)
Q = 1l / min. + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
1400 W
900 W
1700 W
1250 W
Max. delivery head
45 m
(147 ft. 7.65 in.)
Max. delivery rate
3 l/min
(0.79 gal./min [US])
Max. pump pressure at 4750 rpm
4 bar
(58.02 psi)
Pump
Centrifugal pump
Pump service life
up to 30,000 hrs
Coolant capacity
6 l
(1.59 gal. [US])
Degree of protection
IP 23
Dimensions l/w/h
710/300/230 mm
(27.95/11.81/9.06 in.)
Weight (without coolant)
12 kg
(26.46 lb.)
Flow monitoring
(sensor)
Warning at 1 - 0.7 l/min
(0.26 - 0.18 gal./min [US])
Error message below 0.7 l/min
(0.18 gal./min [US])
Coolant temperature monitoring
Warning above 68 °C (154.4 °F)
Error message above 70 °C (158 °F)
Level sensor
(function depends on the options installed
in the device)
Warning or error message
Mark of conformity
CE, CSA
81
EN
Summary of Contents for CU 1100i
Page 2: ......
Page 16: ...16...
Page 17: ...General information 17...
Page 18: ...18...
Page 26: ...26...
Page 27: ...Connections and mechanical com ponents 27...
Page 28: ...28...
Page 31: ...Installation and commissioning 31...
Page 32: ...32...
Page 45: ...Close the cover on the cooling unit connection 3 45 EN...
Page 46: ...46...
Page 47: ...Troubleshooting 47...
Page 48: ...48...
Page 53: ...Care maintenance and disposal 53...
Page 54: ...54...
Page 70: ...70...
Page 71: ...Technical data 71...
Page 72: ...72...
Page 82: ...82...
Page 83: ...83 EN...