24
Define the calibration class:
o Precision
o Standard
25
Click [Start automatic calibration process]
The calibration process starts.
When a calibration process is active
-
A corresponding notification is displayed
-
The [Interrupt calibration] button is available
-
All measuring points are checked one after the other
-
Current measured values are displayed
-
A progress bar with the remaining time is displayed
If the calibration process is interrupted before the welding wire has been cal-
ibrated, a corresponding notification is displayed.
26
Change over welding system for wire calibration
(see page
)
CAUTION!
Risk of injury from emerging welding wire.
As soon as the calibration process resumes, the welding wirefeed starts and the
welding wire emerges.
▶
Keep the welding wire calibration system away from the head and body and
wear suitable protective goggles.
▶
Make sure that when the welding wire emerges, it does not touch any elec-
trically conducting, earthed or live parts.
▶
Make sure that there is sufficient space for the emerging welding wire (ap-
prox. 10 m).
▶
Make sure that no one is endangered by the emerging welding wire.
27
click [OK] to start calibrating the wirefeeder system
When wire calibration is complete, a message to reverse the polarity of the
WeldCube Connector is displayed.
88
Summary of Contents for Calibration system 2.0
Page 2: ......
Page 13: ...General information 13...
Page 14: ...14...
Page 22: ...22...
Page 23: ...Controls connections and mechan ical components 23...
Page 24: ...24...
Page 28: ...28...
Page 29: ...Installation 29...
Page 30: ...30...
Page 38: ...38...
Page 39: ...Calibrating welding systems 39...
Page 40: ...40...
Page 47: ...2 2 Connect the Signotec signature pad to the calibration system 47 EN...
Page 90: ...90...
Page 91: ...Troubleshooting 91...
Page 92: ...92...
Page 95: ...Technical data 95...
Page 96: ...96...
Page 99: ...99 EN...