Safety
Permitted uses
Fröling Heizkessel- und Behälterbau Ges.m.b.H Industriestraße 12 A-4710 Grieskirchen
Page 9
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 [email protected] www.froeling.com
B 067 00 09
2
2.2
Permitted uses
The boiler should only be operated when it is in full working order. It
should be operated in accordance with the instructions, observing safety
precautions, and you should ensure you are aware of the potential
hazards. Ensure that any faults, which might impair safety, are rectified
immediately.
The TX series wood chip boiler is intended exclusively for
heating central heating water. Use only the fuels specified
under 2.2.1.
The manufacturer or supplier is not liable for any damages
resulting from non-permitted uses.
2.2.1
Permitted fuels
Wood chips
Designation as per
ÖNORM
M 7133
ÖNORM/DIN
CEN/TS 14961
Description as per
ÖNORM M 7133
W20 M20
Air dried
Water
content
W30 M30
Suitable for storage
G30 P16
Fine wood chips
Size
G50 P45
Medium wood chips
Applicable standards:
Austria:
ÖNORM M 7133 or ÖNORM CEN/TS 14961
Germany:
Wood chips in accordance with §3 (1) point 4 of the 1st
BImSchV in the applicable version.
Specifications as per DIN CEN/TS 14961 and/or
ÖNORM M 7133
Pellets
Wood pellets made from natural wood with a diameter of 6 - 10 mm
Applicable standards:
Austria:
ÖNORM M 7135 - HP 1 and/or DINplus certification
program
Germany:
DIN 51731 - HP 5, DINplus certification program and/or
ÖNORM M 7135 - HP 1
Generally applicable:
Before refilling the store, check for pellet dust and clean if necessary.
§
§