Safety
Safety devices
Fröling Heizkessel- und Behälterbau Ges.m.b.H Industriestraße 12 A-4710 Grieskirchen
Page 13
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 [email protected] www.froeling.com
B 067 00 09
2
2.6
Safety devices
1
Automatic operation button
If the boiler overheats:
Press and hold this button for 5 seconds
Automatic operation is switched off and the controller
follows the boiler shutdown procedure
The pumps continue to run!
Never use the main switch!
2
Safety temperature limiter (back
of boiler)
Page 14, Devices for preventing the boiler from overheating
3
Main switch
For shutting down the entire system:
Only switch off the main switch when the boiler has cooled
down and the controller is switched off (“Boiler off” status).
Turn the main switch to the “O” position
The power to all components is switched off.
Not
shown
Water sprinkler system
In case of burn back, the valve of the water sprinkler system
opens and water goes into the gravity shaft as well as the duct
of the feed screw.
This need only be connected when specified by the
authorities.
1
3