Operating the system
Filling/ refilling the store with fuel
Fröling Heizkessel- und Behälterbau Ges.m.b.H Industriestraße 12 A-4710 Grieskirchen
Page 19
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 info@froeling.com www.froeling.com
B 067 00 09
3
3.2.4
Blowing in pellets for a partially emptied store with stirrer
If there is still sufficient fuel in the store (the head of the stirrer is
completely covered with fuel), the store can be filled:
Switch off the boiler by pressing the
button for 5 seconds and
allow it to cool down for at least two hours.
Close all openings to the store to seal out dust
Blow the fuel into the store
3.2.5
Blowing in pellets for an empty store with stirrer
CAUTION! If the head of the stirrer is already free of material
and the arms / spring blades are extended, then the feeder
unit must be active during the filling process, however the
boiler must be in “OFF” status.
Turn off the boiler by pressing the
button for 5 seconds and
allow it to cool down for at least two hours
Close all openings to the store to seal out dust