4.5.6 Installing the door switch
❒ Secure the bracket with pre-mounted door switch to the upper spacer plate with
two thread forming screws M4 x 8
➥ The reel of the door contact switch must protrude at the front from the opening
of the spacer plate.
4.5.7 Installing the back panel
❒ Position the rear thermal insulation on the rear side of the boiler
❒ Insert back panel over induced draught fan
❒ Secure the left and right back panel to the side panel with nine thread forming
screws (A) each
❒ Installing the induced draught cover plates
4
Assembly
Installing the boiler
42
Froeling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.at