Name
S3 Turbo 40
S3 Turbo 45
Test book number
PB0920016
PB0340011
Nominal output
kW
40
45
Boiler class as per EN 303-5: 2012
5
Test data - Emissions in [mg/MJ]
1)
(nominal load / partial load)
Carbon monoxide (CO)
mg/MJ
47 / 296
55 / 190
Nitrogen oxide (NOx)
mg/MJ
82 / 80
85 / 86
Organic hydrocarbons (OGC)
mg/MJ
2 / 12
2 / 7
Dust
mg/MJ
8 / 10
9 / 10
Boiler efficiency (nominal load / partial
load)
%
93.5 / 92.6
94.1
1.The pollutant concentration is specified as a mass based on the energy content of the fuel fed to the combustion system in mg/MJ
Test data - Emissions in [mg/m³]
1)
(nominal load / partial load)
Carbon monoxide (CO)
mg/m³
69 / 435
81 / 280
Nitrogen oxide (NOx)
mg/m³
120 / 118
125 / 127
Organic hydrocarbons (OGC)
mg/m³
2 / 18
3 / 11
Dust
mg/m³
11 / 14
14 / 15
1.Emissions values based on dry flue gas at standard temperature and pressure (0°C, 1013 mbar) with a volume content of oxygen of 13%
Test report data
S3 Turbo 40 - 45
3
Technology
Technical specifications
22
Froeling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.at