Name
S3 Turbo 18
1)
S3 Turbo 20
Test book number
PB0310011
PB0900016
Nominal output
kW
22.5
20
Boiler class as per EN 303-5: 2012
5
1.S3 Turbo 18 only available in Italy
Test data - Emissions in [mg/MJ]
1)
(nominal load)
Carbon monoxide (CO)
mg/MJ
90
100
Nitrogen oxide (NOx)
mg/MJ
91
93
Organic hydrocarbons (OGC)
mg/MJ
6
7
Dust
mg/MJ
7
7
Boiler efficiency
%
91.1
90.8
1.The pollutant concentration is specified as a mass based on the energy content of the fuel fed to the combustion system in mg/MJ
Test data - Emissions in [mg/m³]
1)
(nominal load)
Carbon monoxide (CO)
mg/m³
133
147
Nitrogen oxide (NOx)
mg/m³
134
137
Organic hydrocarbons (OGC)
mg/m³
10
11
Dust
mg/m³
11
11
1.Emissions values based on dry flue gas at standard temperature and pressure (0°C, 1013 mbar) with a volume content of oxygen of 13%
Name
S3 Turbo 30
S3 Turbo 30
1)
Test book number
PB0910016
PB0910016_at
Nominal output
kW
30
31
Boiler class as per EN 303-5: 2012
5
5
4 with partial load
inspection
1.S3 Turbo 30 with 31 kW nominal output only available in Austria and Italy
Test data - Emissions in [mg/MJ]
1)
(nominal load / partial load)
Carbon monoxide (CO)
mg/MJ
62 / –
58 / 486
Nitrogen oxide (NOx)
mg/MJ
84 / –
84 / 70
Organic hydrocarbons (OGC)
mg/MJ
3 / –
3 / 20
Dust
mg/MJ
7 / –
7 / 8
Boiler efficiency
%
92.2 / –
93.3 / 92.4
1.The pollutant concentration is specified as a mass based on the energy content of the fuel fed to the combustion system in mg/MJ
Test data - Emissions in [mg/m³]
1)
(nominal load / partial load)
Carbon monoxide (CO)
mg/m³
91 / –
86 / 714
Nitrogen oxide (NOx)
mg/m³
124 / –
124 / 102
Organic hydrocarbons (OGC)
mg/m³
5 / –
4 / 30
Dust
mg/m³
10 / –
10 / 12
1.Emissions values based on dry flue gas at standard temperature and pressure (0°C, 1013 mbar) with a volume content of oxygen of 13%
Test report data
S3 Turbo 18 - 20
Test report data
S3 Turbo 30
Technology
3
Technical specifications
Installation Instructions S3 Turbo | M1081217_en
21