6
Using the device
CAUTION!
Cut injuries
Sharp cutting edges on the rotors and cutting bars
– The sharp cutting edges on the rotors and cutting
bars can cause cuts to the hands.
Use gloves when changing the cutting rotors and when
cleaning the grinding chamber.
Use the rotor removing handle when working with the
cutting rotors.
NOTICE!
Wear or damage to the device
Operating without a grinding set
– Operating the device without a grinding set can
lead to increased wear or damage to the device.
Only operate the device when the grinding set has
been inserted.
NOTICE!
Damage to mechanical components
Blockage of the cutting mill
– When working on large-grained, harder particles,
blockages can occur due to the increased drawing-
in power of the standard rotor.
Switch the device off immediately in the event of a
blockage and remove the trapped grinding stock.
Using the device