192
PB
UPDATING VRP FIRMWARE
VRP Remote Upgrade Procedure
04
Missing File or Bad Path. An
expected file or folder is
missing on the MCS.
TBD
05
No Revert File.
TBD
08
Bad Software Revision. The
software revision after update
does not match with what is in
the Key File.
Contact Friedrich
09
Bad revert. The attempt to
revert the MCS has failed.
TBD
26
Too many retries. The FMC has
sent to many retried messages
to the MCS in the RU process.
This error implies a connectivity
problem between the FMC and
MCS. Check that the physical
connection is intact. [Diagnostic
# for MCS Comm error]
MCS Poll Errors
MCS Poll errors happen either during initial setup or before transferring a file to the MCS.
Displayed Error Number
Description
Corrective Action
00
Wrong Bootloader. The MCS
has detected it has an incorrect
bootloader for RU.
Contact Friedrich
01
Bad Processor A. Processor A is
not in an appropriate state for
Remote Upgrade.
Reset system and retry.
Otherwise, contact Friedrich
02
Bad Processor B. Processor B is
not in an appropriate state for
Remote Upgrade.
Reset system and retry.
Otherwise, contact Friedrich
Recovery
In all cases where an error is detected, the Remote Upgrade process is terminated and must be
restarted for it to continue. To facilitate this, the system is automatically reset when the Key Card is
removed from the WC. Before doing this be sure to have noted the error displayed on the screen.
After removing the Key Card, wait a few seconds until the WC restarts and the screen goes
momentarily blank. Once the Smart Icon is displayed again, the system is ready for another Remote
Upgrade attempt.
If the screen never seems to reset, there may have been an issue relaying the reset command. In
this case it will be necessary to cycle system power for full recovery.
6
Summary of Contents for VRP12K
Page 46: ...46 OPERATION Component Identification Indoor Coil 36k ...
Page 48: ...48 OPERATION Component Identification Outdoor Coil Monitored by 1 thermistor ...
Page 49: ...49 OPERATION Component Identification Outdoor Fan BLDC Variable Speed 600 1000 RPM ...
Page 53: ...53 OPERATION Component Identification 4 Way Reversing Valve 208 230v Reversing valve assembly ...
Page 177: ...177 UPDATING VRP FIRMWARE Or ...
Page 184: ...184 UPDATING VRP FIRMWARE Open zip file Copy to SD Card Insert into SD Card Slot ...
Page 193: ...193 UPDATING VRP FIRMWARE Retrieving VRP Data Remove SD Card from FMC and Locate DF Folder ...
Page 196: ...196 WIRINGDIAGRAMS 12 24K BTU 208 230V 7 5 10 0 KW Figure 801 Wiring Diagram ...
Page 197: ...197 WIRING DIAGRAMS 12 24K BTU 208 230V 2 5 3 4 5 0 KW Figure 802 Wiring Diagram ...
Page 198: ...198 WIRING DIAGRAMS 12 24K BTU 265V 2 5 3 4 5 0 kW Figure 803 Wiring Diagram ...
Page 199: ...199 WIRING DIAGRAMS 12 24K BTU 265V 7 5 10 kW Figure 804 Wiring Diagram ...
Page 200: ...200 WIRING DIAGRAMS 36K BTU 208 230V Figure 805 Wiring Diagram ...