- 32 -
Part 4 Trouble Shooting
7. Self-diagnosis Function
■
Error Indicator
• The function is to self-diagnosis airconditioner and express the troubles identically if there is any trouble.
• If more than two troubles occur simultaneously, primarily the highest trouble of error code is expressed.
• After error occurrence, if error is released, error LED is also released simultaneously.
• To operate again on the occurrence of error code, be sure to turn off the power and then turn on.
• Having or not of error code is different from Model.
■
Indoor Unit Error
1. SW, SB, SC, SH, S4, S5 Chassis
1) SW, SB, SC, Chassis
2) S4, S5 Chassis (4 LED Model)
1 Digit
10 Digit
LED1
(1 Digit)
LED2
(10 Digit)
Ex) Error Code 5 (Communication Failure)
LED1
(1 Digit)
LED2
(10 Digit)
LED1
(1 Digit)
LED2
(10 Digit)
3) SH Chassis
2. SE Mirror, S8, SD, SM, SN Chassis
Error
code
Description
Error indication
Indoor unit
LED1
LED2
1
Indoor Sensor (Air) open/short
1 Time
-
2
Indoor Sensor (Entry Pipe) open/short
2 Times
-
4
Float Switch Error
4 Times
-
5
Communication Failure (Indoor Unit
↔
Outdoor Unit)
5 Times
-
6
Indoor Sensor (Exit Pipe) open/short
6 Times
-
9
EEPROM ERROR (Indoor Unit)
9 Times
-
10
Indoor Unit Fan Lock (Operation Failure)
-
1 Time
12
Indoor Sensor (Middle Pipe) open/short
2 Times
1 Time
Summary of Contents for AS - W126BMS0
Page 3: ...3 1 Safety Precautions 4 2 Nomenclature 7 Part 1 General Information...
Page 16: ...16 Part 3 Test Run 1 Check before Test Run 17 2 Test Run Flow chart 18 3 Test Run Detail 19...
Page 37: ...Part 4 Trouble Shooting 37 Troubleshooting Guide Indoor Unit...
Page 41: ...Part 4 Trouble Shooting 41 verify with hands verify with hands...
Page 46: ...Part 4 Trouble Shooting 46 3 CH23 DC Link Low Voltage Error...
Page 51: ...Part 4 Trouble Shooting 51 8 CH40 CT Sensor Error Open Short Tester Tester...
Page 53: ...Part 4 Trouble Shooting 53 10 CH53 Outdoor Unit Indoor Unit Communication Error...
Page 56: ...Part 4 Trouble Shooting 56 13 CH62 Heat Sink Overheat Error...
Page 59: ...Part 4 Trouble Shooting 59 Resistance between the lines of each 1 5 2 1 5 2 1 5 2 U V V W W U...
Page 61: ...Part 4 Trouble Shooting 61 3 CH23 DC Link Low Voltage Error...
Page 67: ...Part 4 Trouble Shooting 67 9 CH53 Outdoor Unit Indoor Unit Communication Error...
Page 68: ...Part 4 Trouble Shooting 68 10 CH60 Outdoor Unit PCB EEPROM Error...
Page 71: ...Part 4 Trouble Shooting 71 13 CH67 Outdoor BLDC Fan Lock Error...