Part 4 Trouble Shooting
- 38 -
Measure resistance
Refer to Check Point
Resistance is adequate?
Sensor OK
Resistance (White)
200~165
㏀
@25~30°C
Resistance (Black)
10~8
㏀
@25~30°C
Resistance (Blue)
5~4
㏀
@25~30°C
Yes
No
Replace Sensor
❏
Discharge Pipe Temp Sensor (200
㏀
)
❏
Air/Room Temp. Sensor (10
㏀
)
❏
Indoor Pipe Temp. Sensor (5
㏀
)
Check Point
1. 10k Ω / at 25℃(77℉)±10%
2. 5k Ω / at 25℃(77℉)±10%
3. 200k Ω / at 25℃(77℉)±10%
Check Method
❈
For more information, please refer to the 38 page table.
Summary of Contents for AS - W126BMS0
Page 3: ...3 1 Safety Precautions 4 2 Nomenclature 7 Part 1 General Information...
Page 16: ...16 Part 3 Test Run 1 Check before Test Run 17 2 Test Run Flow chart 18 3 Test Run Detail 19...
Page 37: ...Part 4 Trouble Shooting 37 Troubleshooting Guide Indoor Unit...
Page 41: ...Part 4 Trouble Shooting 41 verify with hands verify with hands...
Page 46: ...Part 4 Trouble Shooting 46 3 CH23 DC Link Low Voltage Error...
Page 51: ...Part 4 Trouble Shooting 51 8 CH40 CT Sensor Error Open Short Tester Tester...
Page 53: ...Part 4 Trouble Shooting 53 10 CH53 Outdoor Unit Indoor Unit Communication Error...
Page 56: ...Part 4 Trouble Shooting 56 13 CH62 Heat Sink Overheat Error...
Page 59: ...Part 4 Trouble Shooting 59 Resistance between the lines of each 1 5 2 1 5 2 1 5 2 U V V W W U...
Page 61: ...Part 4 Trouble Shooting 61 3 CH23 DC Link Low Voltage Error...
Page 67: ...Part 4 Trouble Shooting 67 9 CH53 Outdoor Unit Indoor Unit Communication Error...
Page 68: ...Part 4 Trouble Shooting 68 10 CH60 Outdoor Unit PCB EEPROM Error...
Page 71: ...Part 4 Trouble Shooting 71 13 CH67 Outdoor BLDC Fan Lock Error...