- 14 -
Part 2 Functions & Controls
4.3 Air volume control
• UIndoor fan motor control have 6 steps or 8 steps.
• UAir volume is controlled "SH", "H", "MH", "M", "ML", "L" by the
remote controller.
• "SL" step is selected in "Sleep Mode" operation.
4.4 Natural Air Control(Natural Wind)
• When the Auto Step is selected and then operated, the high, medi-
um, or low speed of the airflow mode is operated for 2~15 sec. ran-
domly by the Chaos Simulation.
4.5 Auto Swing
• By the Auto swing key input, the horizontal vane automatically operates with the Auto swing or it is fixed to the desired
direction.
4.6 Sleep mode Auto control
• When the set sleep time is reached set time of [1,2,3,4,5,6,7hour] input by the remote control during the operation, the
operation of the appliance stops.
• When the appliance is on pause, the sleep timer mode cannot be input.
4.6.1 Sleep timer operation for cooling cycle
• While in cooling mode , 30 min. after the start of the sleep timer, the setting temperature increases by 1
°
C(2
°F)
.
After another 30minutes lapse, it increases again by 1°C(2
°F)
.
SL
Super Low
L
Low
ML
Medium-Low
M
Medium
MH
Medium-High
H
High
SH
Super High
Auto
Natural Wind
Step
Description
NOTE
: Some Models are different by swing width and swing pattern.
Setting temp. (˚C)
1.0˚C(2˚F) up
1.0˚C(2˚F) up
Cooling ON temp.
(Setting temp. +0.5˚C(+1˚F))
Cooling OFF temp.
(Setting temp. -0.5˚C(-1˚F))
0.5
1
Sleep time (hour)
Summary of Contents for AS - W126BMS0
Page 3: ...3 1 Safety Precautions 4 2 Nomenclature 7 Part 1 General Information...
Page 16: ...16 Part 3 Test Run 1 Check before Test Run 17 2 Test Run Flow chart 18 3 Test Run Detail 19...
Page 37: ...Part 4 Trouble Shooting 37 Troubleshooting Guide Indoor Unit...
Page 41: ...Part 4 Trouble Shooting 41 verify with hands verify with hands...
Page 46: ...Part 4 Trouble Shooting 46 3 CH23 DC Link Low Voltage Error...
Page 51: ...Part 4 Trouble Shooting 51 8 CH40 CT Sensor Error Open Short Tester Tester...
Page 53: ...Part 4 Trouble Shooting 53 10 CH53 Outdoor Unit Indoor Unit Communication Error...
Page 56: ...Part 4 Trouble Shooting 56 13 CH62 Heat Sink Overheat Error...
Page 59: ...Part 4 Trouble Shooting 59 Resistance between the lines of each 1 5 2 1 5 2 1 5 2 U V V W W U...
Page 61: ...Part 4 Trouble Shooting 61 3 CH23 DC Link Low Voltage Error...
Page 67: ...Part 4 Trouble Shooting 67 9 CH53 Outdoor Unit Indoor Unit Communication Error...
Page 68: ...Part 4 Trouble Shooting 68 10 CH60 Outdoor Unit PCB EEPROM Error...
Page 71: ...Part 4 Trouble Shooting 71 13 CH67 Outdoor BLDC Fan Lock Error...
Page 72: ...P No MFL41161608...