it is recommended to place new ones. Part nr.
9110260 (2x 1mtr).
1. Mount the name panel on the right hand
side.
2. Hook in the control panel on the left side
and fix it with the front side top screw.
3. Lead the RS232 cable and the ribbon cable
to the left side and connect them to the pcb.
4. Extend both earth wires or take longer new
ones and connect them to the pcb and the
control panel.
5. Close the panel and fix it.
The below is not necessary!
6. Move the emergency switch to the left side
according to the procedure below.
It is difficult to do this for the first time because
it is not possible to see the mounting nut and
the lever of the adapter to release the adapter
with the switches from the knob. See pictures.
7. Push up the lever and pull the adapter with
the switches.
8. Loosen the mounting nut and take out the
knob.
9. Drill out the 2 rivets from the type plate.
10. Mount the type plate on the right hand side.
11. Mount the knob on the left side.
12. Click the adapter with the switches on the
knob.
Necessary parts.
9079140 3 mtr earth wire 2,5²mm.
2005763 3x ring terminal (for crimping on
the earth wire)
9110260 2 mtr foam gasket.
9009213 2 rivets 2,5mm
9291017 USB extension cable
Release lever
Mounting nut
Knob Adapter Switches