Page 31
Service Procedures
Service Manual Deli Multisserie form 9123560 rev. 02/2017
18.Mark the position of the flat surface on
the shaft, on the shaft head.
19.Place the blade in such a way that the soc-
ket set-screw is positioned square to the
flat surface on the shaft.
Keep blower motor and fan blade together!!
20.Slowly fasten the set-screw while the
centre of the flat surface is searched by
moving the ventilator blade with short
left/right movements. Slide the ventilator
blade as far as possible to the back on the
shaft.
21.Fasten the screw.
22.Place the fan plate [277].
23.Fasten the swivels of the waterinjection-
joints [227] while holding the joint with
a 17 and 19mm wrench. Take care of the
distance of the pipes to the ventilator
shaft!! 1/4”- 3/8”.
24.Place the 4 spacers [276] and mount the
filter support [275] (4 nuts M6).
25.Place the fat filters [278].
Mount the nut from the soap mister [450]
if applicable.
26.Put in the chicken racks and/or meatbas-
kets.
ASSEMBLING THE BLOWERS (CONTINUED)
23
24
25
19
18
1/4” - 3/8”
!